Complete denture making in a patient of partial glossectomy using polished surface impression taking and direct metal laser sintering method: A case report  

Jung, Yeon-Wook (Department of Prosthodontics, College of Dentistry, Chosun University)
Lee, Gyeong-Je (Department of Prosthodontics, College of Dentistry, Chosun University)
Kim, Hee-Jung (Department of Prosthodontics, College of Dentistry, Chosun University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.57, no.4, 2019 , pp. 350-355 More about this Journal
Abstract
For the success of complete denture, three essential requirements such as retention, stability and support are needed. Moreover, due to the absorption of residual ridge and scarring due to the surgery, when making a complete denture, which is difficult to form the mandibular lingual margins, various considerations such as the arrangement of the Non-anatomical dl non-anatomical teeth, the polished surface impression, the internally weighted metal framework and the use of the denture adhesive cream are necessary. In this case report, the patient has a severely resorbed edentulous ridge from severe periodontitis and has some soft tissue problems after the glossectomy due to tongue cancer. To obtain additional retention and stability, some trials such as polished surface impression taking, internally weighted metal insertion and minimal pressure impression were done for the better result. Moreover To make a metal framework that precisely shapes the desired three-dimensional shape and reduces the complicated process, minimal pressure impression method and direct metal laser sintering technique were used.
Keywords
Partial glossectomy; Polished surface impression; Direct metal laser sintering;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bencharit S, Schardt-Sacco D, Border MB, Barbaro CP. Full mouth rehabilitation with implant-supported prostheses for severe periodontitis: a case report. Open Dent J 2010;4:165-71.   DOI
2 Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. The implant-supported overdenture as an alternative to the complete mandibular denture. J Am Dent Assoc 2003;134:1455-8.   DOI
3 MacEntee MI, Walton JN. The economics of complete dentures and implant-related services: a framework for analysis and preliminary outcomes. J Prosthet Dent 1998;79:24-30.   DOI
4 Jacobson TE, Krol AJ. A contemporary review of the factors involved in complete dentures. Part II: stability. J Prosthet Dent 1983;49:165-72.   DOI
5 Pleasure MA. Anatomic versus nonanatomic teeth. J Prosthet Dent 1953;3:747-54.   DOI
6 Kapur KK, Soman S. The effect of denture factors on masticatory performance: Part II: Influence of the polished surface contour of denture base. J Prosthet Dent 1965;15:231-40.   DOI
7 Hazari P, Yadav M, Gaikwad A, Singh V, Somkuwar K. Internally weighted dentures: a treatment modality for severely resorbed mandibular ridge: a case report. J Evol Med Dent Sci 2014;3:10374-8.   DOI
8 Ciocca L, Fantini M, De Crescenzio F, Corinaldesi G, Scotti R. Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches. Med Biol Eng Comput 2011;49:1347-52.   DOI
9 Cawood JI, Howell RA. A classification of the edentulous jaws. Int J Oral Maxillofac Surg 1988;17:232-6.   DOI
10 Tallgren A. The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years. J Prosthet Dent 1972;27:120-32.   DOI
11 Lytle RB. Soft tissue displacement beneath removable partial and complete dentures. J Prosthet Dent 1962;12:34-43.   DOI
12 Ikebe K, Morii K, Kashiwagi J, Nokubi T, Ettinger RL. Impact of dry mouth on oral symptoms and function in removable denture wearers in Japan. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2005;99:704-10.   DOI
13 Zlataric DK, Celebic A. Clinical bone densitometric evaluation of the mandible in removable denture wearers dependent on the morphology of the mandibular cortex. J Prosthet Dent 2003;90:86-91.   DOI
14 Pleasure MA. Prosthetic occlusion-A problem in mechanics. J Am Dent Assoc Dent Cosm 1937;24:1303-18.   DOI
15 Thomson JC. The load factor in complete denture intolerance. J Prosthet Dent 1971;25:4-11.   DOI
16 Kim H, Brewer JD, Monaco E. Internally weighted mandibular denture fabrication using a processed denture base. J Prosthet Dent 2009;102:123-5.   DOI
17 Papadiochou S, Emmanouil I, Papadiochos I. Denture adhesives: a systematic review. J Prosthet Dent 2015;113:391-7.   DOI
18 Beresin VE, Schiesser FJ. The neutral zone in complete dentures. 1976. J Prosthet Dent 2006;95:93-100.   DOI
19 Grunewald AH. Gold base lower dentures. J Prosthet Dent 1964;14:432-41.   DOI
20 Balch JH, Smith PD, Marin MA, Cagna DR. Reinforcement of a mandibular complete denture with internal metal framework. J Prosthet Dent 2013;109:202-5.   DOI