Browse > Article

CASE REPORTS ON THE MAGNETIC RETAINED OVERDENTURES  

Vang Mong-Sook (Department of Prosthodontics, College of Dentistry, Chonnam National University)
Choi Chang-Hwan (Department of Prosthodontics, College of Dentistry, Chonnam National University)
Kim Young-Yi (Department of dental hygiene Chunnam Techno college)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.40, no.1, 2002 , pp. 88-97 More about this Journal
Abstract
The purpose of this study was to evaluate a cases which was treated with magnetic attachments on the patients in edentulous mandible and maxilla. Author made magnetic overdenture for two patients and then clinical examination were used for evaluation of the function and change in retention during 30months. Patients showed difficulty in oral hygiene care at the beginning but they go used to it soon. It was effective in promotion of denture retention and stability and also gave patient emotionally uplifting psychologic state. This study suggest that magnetic attachment was effective for the treatment of patients presenting a few remaining teeth or teeth under severe caries or mobility.
Keywords
Magnetic attachment; Edentulous mandible and maxilla; Overdenture oral Hygiene; Retention; stability;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Jacksori TR, New rare earth magnetic technology: The Jackson Solid State Attachment system. Trends & Techniques 1986;31-39
2 Gendusa NJ. Magnetically retained overlay dentures. Quint Int 1988;19:265-271
3 Gillings BRD. Intra radicular anchorage of overlay dentures using cobalt rare earth magnets. ASP Bulletin 1977;27-31
4 Tsutsui H, Kinouchi Y, Sasaki H, Shiota M. Ushita T. Studies on the Sm-Co magnet as a dental material. J Dent Res 1979; 58:1597-1606   DOI   PUBMED   ScienceOn
5 Vrijhhoef MMa, Mezger PR, Van der Zell JM, Greener EH, Corrosion of ferromagnet alloys used for magnetic retention of overdentures. J Dent Res 1987;66: 1456-1459
6 Angelini E, Pezzoli M, Zucchi F, Corrosion under static and dynamic conditions of alloys used for magnetic retention in dentistly. J Prosthet Dent 1991;66:536-540
7 Kitsugi A, Okuno O, Nakano T, Hamanaka H, Kuroda T. The corrosionbehaviour of Nd-Fe-B and SmCo5 magnets. Dent Mater J 1992;11:119-129   DOI   PUBMED
8 Vardimon AD, Mueller HJ. In-vivo and in-vitro corrosion of permanent magnets in orthodontic therapy, J Dent Res(Abs no. 89)1985;184
9 Saygili G, Aydinlik E, Ercan MT. Investigation of the effect of magnetic retention systems used in prostheses on buccal mucosal blood flow. Int J Prosthodont 1992;5:326-332   PUBMED
10 Allen A. brewer, Robert M. morrow. Overdentures second edition 1985 ;4-10
11 Jackson TR. The application of rare earth magnetic retention to osseointegrated implants. Int J Oral Maxillofac Imp 1986; 17: 571-586
12 고영무, 김경남, 김광만 인공타액에서 치광용 자성재의 전기화학적 부식에 대한 스퍼터링 도금의 효과. 대한치과기재학회지 1997;24(2): 343-360
13 Connor RJ, Svare CW. Proplast-coated high strength magnets as potential denture stabilization devices J PROSTHET DENT 1977;37:339-343
14 Gillings BRD. Magneic retention for the overdenture. Overdentures C.V. Mosby 1980;376-397
15 Behrman SJ. The implantation of magnets in the jaw to aid denture retention J Prosthet Dent 1960;10: 807-841
16 Shmitz J. Measurement of the efficiency of the platinum-cobalt magnetic implant. J Prosthet Dent 1966;16(6):1151-1158   DOI   ScienceOn
17 M.A Riley, A.J Williams, A.D Walmsley. Investigations into the failure of dental magnets The Int J of Prosthodontics 1999;12(3):249-254
18 Gillings BR. Magnetic denture retention system. In: Prieskel HW. Precision attachments in prosthodontics. Vol II. Chicago: Quintessence 1977:191-241
19 Gillings BRD, Magnet denture retention system. In: Prieskel HW. Precesion attachments in Prosthodontics. Vol II. Chicago: Quintessence 1985; 191-241
20 Freedman H. Magnets to stabilize dentures JADA 1953;47:288-297
21 Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Prosthet Dent 1991;66:536-40   DOI   ScienceOn
22 Toto PD, Choukas NC, Sanders DD. Reaction of bone and mucosa to implanted magnets. J Dent Res 1962; 41(6): 1438-1449   DOI   ScienceOn
23 Cerny R. The biologic effects of implanted magnetic fields Part I. Mammalian blood cells. Aust Orthod J 1979;6:64-70   PUBMED
24 Smith GA, Laird WRE, Grant AA, Magnetic retention units for overdentures. J Oral Rehabil 1989;10: 481-488
25 Moghadam BK, Skandrett FR, Magnetic retention for overdentures. J Prosthetic Dent 1979;41 :26-29
26 Funda Akaltan. PhD, and Gulsen Can, DDS, Retentive characteristics of different dental magnetic systems, J Prosthet Dent 1995;74:422-7   DOI   ScienceOn
27 Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Rrosthet Eent 1991; 66:848-853