1 |
Jacksori TR, New rare earth magnetic technology: The Jackson Solid State Attachment system. Trends & Techniques 1986;31-39
|
2 |
Gendusa NJ. Magnetically retained overlay dentures. Quint Int 1988;19:265-271
|
3 |
Gillings BRD. Intra radicular anchorage of overlay dentures using cobalt rare earth magnets. ASP Bulletin 1977;27-31
|
4 |
Tsutsui H, Kinouchi Y, Sasaki H, Shiota M. Ushita T. Studies on the Sm-Co magnet as a dental material. J Dent Res 1979; 58:1597-1606
DOI
PUBMED
ScienceOn
|
5 |
Vrijhhoef MMa, Mezger PR, Van der Zell JM, Greener EH, Corrosion of ferromagnet alloys used for magnetic retention of overdentures. J Dent Res 1987;66: 1456-1459
|
6 |
Angelini E, Pezzoli M, Zucchi F, Corrosion under static and dynamic conditions of alloys used for magnetic retention in dentistly. J Prosthet Dent 1991;66:536-540
|
7 |
Kitsugi A, Okuno O, Nakano T, Hamanaka H, Kuroda T. The corrosionbehaviour of Nd-Fe-B and SmCo5 magnets. Dent Mater J 1992;11:119-129
DOI
PUBMED
|
8 |
Vardimon AD, Mueller HJ. In-vivo and in-vitro corrosion of permanent magnets in orthodontic therapy, J Dent Res(Abs no. 89)1985;184
|
9 |
Saygili G, Aydinlik E, Ercan MT. Investigation of the effect of magnetic retention systems used in prostheses on buccal mucosal blood flow. Int J Prosthodont 1992;5:326-332
PUBMED
|
10 |
Allen A. brewer, Robert M. morrow. Overdentures second edition 1985 ;4-10
|
11 |
Jackson TR. The application of rare earth magnetic retention to osseointegrated implants. Int J Oral Maxillofac Imp 1986; 17: 571-586
|
12 |
고영무, 김경남, 김광만 인공타액에서 치광용 자성재의 전기화학적 부식에 대한 스퍼터링 도금의 효과. 대한치과기재학회지 1997;24(2): 343-360
|
13 |
Connor RJ, Svare CW. Proplast-coated high strength magnets as potential denture stabilization devices J PROSTHET DENT 1977;37:339-343
|
14 |
Gillings BRD. Magneic retention for the overdenture. Overdentures C.V. Mosby 1980;376-397
|
15 |
Behrman SJ. The implantation of magnets in the jaw to aid denture retention J Prosthet Dent 1960;10: 807-841
|
16 |
Shmitz J. Measurement of the efficiency of the platinum-cobalt magnetic implant. J Prosthet Dent 1966;16(6):1151-1158
DOI
ScienceOn
|
17 |
M.A Riley, A.J Williams, A.D Walmsley. Investigations into the failure of dental magnets The Int J of Prosthodontics 1999;12(3):249-254
|
18 |
Gillings BR. Magnetic denture retention system. In: Prieskel HW. Precision attachments in prosthodontics. Vol II. Chicago: Quintessence 1977:191-241
|
19 |
Gillings BRD, Magnet denture retention system. In: Prieskel HW. Precesion attachments in Prosthodontics. Vol II. Chicago: Quintessence 1985; 191-241
|
20 |
Freedman H. Magnets to stabilize dentures JADA 1953;47:288-297
|
21 |
Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Prosthet Dent 1991;66:536-40
DOI
ScienceOn
|
22 |
Toto PD, Choukas NC, Sanders DD. Reaction of bone and mucosa to implanted magnets. J Dent Res 1962; 41(6): 1438-1449
DOI
ScienceOn
|
23 |
Cerny R. The biologic effects of implanted magnetic fields Part I. Mammalian blood cells. Aust Orthod J 1979;6:64-70
PUBMED
|
24 |
Smith GA, Laird WRE, Grant AA, Magnetic retention units for overdentures. J Oral Rehabil 1989;10: 481-488
|
25 |
Moghadam BK, Skandrett FR, Magnetic retention for overdentures. J Prosthetic Dent 1979;41 :26-29
|
26 |
Funda Akaltan. PhD, and Gulsen Can, DDS, Retentive characteristics of different dental magnetic systems, J Prosthet Dent 1995;74:422-7
DOI
ScienceOn
|
27 |
Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Rrosthet Eent 1991; 66:848-853
|