Browse > Article
http://dx.doi.org/10.5392/JKCA.2020.20.10.395

Comparison of Radiopharmaceutical Dosing Rate Measurements Using Plastic Syringes and Norm-ject Syringes  

Son, Sang-Joon (대구파티마병원 핵의학과)
Park, Jeong-Kyu (대구보건대학교 방사선과)
Publication Information
Abstract
Between October 2019 and January 2020, 120EA of a syringe that was equipped with a 3-way injection material and administered 99mTc labeled compound among inpatients for SPECT examination at the Department of Nuclear Medicine at Daegu P Hospital. When using a plastic syringe, the average dosing rate according to the number of dilutions was 99mTc-ECD the highest at 90.87±11.08, and 99mTc-DMSA the lowest at 75.28±7.43. The average dose rate according to the number of dilutions was the highest at 93.58±7.96, and the lowest at 99mTc-DMSA at 91.60±6.07. The independent sample t-test showed whether the difference between the 99mTc-DMSA plastic syringe and the normjek syringe was statistically significant(p<0.01). The 99mTc-DMSA used for radiopharmaceuticals is a radiopharmaceutical that is mainly used for pediatric patients, and it is considered that it is necessary to use a normjek syringe rather than a general plastic syringe because the precise dosage is important.
Keywords
Nuclear Medicine; 3-Way Injection Material; Plastic Syringe; Nomjeck Syringe;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 고창순, 정준기, 이명철, 핵의학, 고려의학, 2008.
2 Urska Dermol and Branko Kontic, "Use of strategic environmental assessment in the site selection process for a radioactive waste disposal facility in Slovenia," Journal of Environmental Management, Vol.92, No.1, pp.43-52, 2010.   DOI
3 International Atomic Energy Agency (IAEA), Alternative technologies for 99mTc generators, Final report of a co-ordinated research programme 1990-1994, IAEA-TECDOC-852, 1995.
4 International Atomic Energy Agency (IAEA), Techical Report Series No.466, Technetium-99mRadio-pharmaceuticals:Manufacture of kit, Vienna, IAEA, 2008.
5 Matthias Bauwens, "Retention of 99mTc-DMSA(III) and 99mTc-nanocolloid in different syringes affects imaging quality," Nuclear Medicine Communications, Vol.35, No.4, pp.433-437, 2014.   DOI
6 W. H. Lee and S. M. An, "Experiment to Calculate the Dosage of Radiopharmaceutical Products during the Bone Scan Tests," The Journal of the Korea Contents Association, Vol.15, No.4, pp.357-362, 2015.   DOI
7 https://ipb.fi/shop/norm-ject-luer-slip-syringe-100kpl/, 2020.06.01.
8 https://www.law.go.kr/main.html, 2020.06.10.
9 Korea Atomic Energy Safety & Technology Institute, "Workshop for improving safety management in the medical field, and regulatory measures for possession and use of dose calibrators," 2017.
10 이준일, 핵의학기술학, 대학서림, 2003.
11 J. E. Towson and R. C. Smart, "Diagnostic ReferenceActivities for Nuclear Medicine, in Australia and Newzealand," International Atomatic Energy Agency, 2001.
12 Abdelhamid H. Elgazzar and Ismet Sarikaya, Nuclear Medicine Companion. A Case-Based Practical Reference for Daily Use, Springer International Pub, 2018.
13 김가중, 배석환, 김기진, 오혜경, "양전자 방출핵종의 감마에너지가 X선 CT영상에 미치는 영향," 한국산학기술학회 논문지, 제12권, 제10호, pp.4418-4424, 2011.
14 C. R, Seon and J. W. Gil, "Study on Development of Patient PatiEffective Dose Calculation Program of Nuclear Medicine Examination," Vol.18, No.3, pp.657-665, 2017.   DOI