Browse > Article
http://dx.doi.org/10.4334/JKCI.2004.16.4.541

A Study on the Sound Absolution Properties of Porous Concrete by Recycled Aggregate Contents and Target Void Ratio  

Park Seung-Bum (Dept. of Civil Engineering, Chungnam National University)
Seo Dae-Seuk (Dept. of Civil Engineering, Chungnam National University)
Lee Jun (Dept. of Civil Engineering, Chungnam National University)
Publication Information
Journal of the Korea Concrete Institute / v.16, no.4, 2004 , pp. 541-548 More about this Journal
Abstract
This study peformed an evaluation of the physical and mechanical properties and sound absorption characteristics of porous concrete according to the target void ratio and content of the recycled aggregate in order to reduce the noise generated in roads, railroads, residential areas and downtown areas and effectively utilize the recycled waste concrete aggregate generated as a byproduct of construction. The test results demonstrated that the difference between the target void ratio and the actual measured void ratio was less than 1.7% and that the tendency of the compression strength was to reduce rapidly when the target void ratio and the content of the recycled aggregate exceeded 25% and 50%, respectively. In addition, the sound absorption characteristics of the porous concrete using recycled waste concrete aggregate showed that the NRC was the highest at the target void ratio of 25% and the content of the recycled aggregate had very little influence on the NRC. Therefore, when considering the compression strength and the sound absorption characteristics of porous concrete, the proper target void ratio and the content of the recycled waste concrete aggregate are thought to be 25% and 50%, respectively
Keywords
porous concrete; sound absorption; recycled aggregate; void ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 환경부, '2001년도 전국폐기물 발생 및 처리현황', 환경부, 2002
2 日本 コンクート 工學協會, 'エココンクリート(ECO Concrete)研究委員會報告', 日本 コンクート 工學協會, 1995, pp.56~58
3 KS F 2814-1, '임피던스관에의한 홉음계수와 임피던스의 결정 방법', 2001
4 M Tarnai and M Tanaka, 'Sound Absorbing Property of Porous Concrete Using Shirasu Pumice', Transactions of The Japan Concrete Institute', Vol. 16, 1994, pp.81~88
5 KS F 2805, '잔향실 내의 흡음률측정방법', 2001
6 ISO 354, 'Acoustics-Measurement of Sound Absorption in a reverberation room', 1985
7 中澤隆雄, 張 雪梅, 三浦 功, 張 日紅, 'ポーラスコンクリートの吸音特性について', 日本コンクリート工學協會, ポーラスコンクリートの設計 . 施工法と最近の適用例に關よるシンポヅウム論文集, 2002, pp.127~132
8 中澤隆雄, 張 雪梅, 新西成男, 滨山征也 'ポーラスコンクリートの骨材粒徑および 空隙率が吸音性能に及ぼす影響, コンクリート工學年次論文集, Vol.23, No.1, 2001, pp.163~168
9 박승범 외, '시멘트산업부산물을 이용한 소음저감형 벽체소재 개발', 산업자원부, 2003, pp.1~8
10 堂園昭人, 岡本享久, 藤原浩巳, 上野雅之. '管內法によるポーラスコンクリートの 吸音特性 に關する基礎的研究コンクート工學年次論文報告集, Vol.19, No.1, 1997, pp.679~684
11 박승범, '순환경 사회구축을 위한 환경친화 콘크리트기술의 현황과 전망', 콘크리트학회지, 15권, 6호, 2003, pp.14~16
12 박승범, '흡음콘크리트', 콘크리트학회지, 12권, 5호, 2000, pp.33~370