Flow Characteristics Evaluation in Reactor Coolant System for Full System Decontamination of Kori-1 Nuclear Power Plant  

Kim, Hak Soo (Korea Hydro & Nuclear Power Co., Central Research Institute)
Kim, Cho-Rong (Korea Hydro & Nuclear Power Co., Central Research Institute)
Publication Information
Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT) / v.16, no.3, 2018 , pp. 389-396 More about this Journal
Abstract
The Kori-1 Nuclear Power Plant (NPP), WH 2-Loop Pressurized Water Reactor (PWR) operated for approximately 40 years in Korea, was permanently ceased on June 18, 2017. To reduce worker exposure to radiation by reducing the dose rate in the system before starting main decommissioning activities, the permanently ceased Kori-1 NPP will be subjected to full system decontamination. Generally, the range of system decontamination includes Reactor Pressure Vessels (RPV), Pressurizer (PZR), Steam Generators (SG), Chemical & Volume Control System (CVCS), Residual Heat Removal System (RHRS), and Reactor Coolant System (RCS) piping. In order to decontaminate these systems and equipment in an effective manner, it is necessary to evaluate the influence of the flow characteristics in the RCS during the decontamination period. There are various methods of providing circulating flow rate to the system decontamination. In this paper, the flow characteristics in Kori-1 NPP reactor coolant according to RHR pump operation were evaluated. The evaluation results showed that system decontamination using an RHR pump was not effective at decontamination due first to impurities deposited in piping and equipment, and second to the extreme flow unbalance in the RCS caused deposition of impurities.
Keywords
Kori-1 nuclear power plant; System decontamination; Range of system decontamination; RHR pump;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Electric Power Research Institute, "Decontamination Handbook", Electric Power Research Institute Report, EPRI TR-112352 (1999).
2 Electric Power Research Institute, "Evaluation of the Decontamination of the Reactor Coolant Systems at Maine Yankee and Connecticut Yankee", Electric Power Research Institute Report, EPRI TR-112092 (1999).
3 Electric Power Research Institute, "Jose Cabrera Nuclear Power Plant Full System Chemical Decontamination Experience Report", Electric Power Research Institute Report, EPRI TR-109230 (2009).
4 Korea Hydro & Nuclear Power Co. LTD., "Final Safety Analysis Report of Kori unit 1", Kori Unit 1 Nuclear Power Plant (2014).
5 Korea Hydro & Nuclear Power Co. LTD., "Final Safety Analysis Report of Kori Unit 3&4", Kori Units 3&4 Nuclear Power Plants (2015).