Derivation of a Verification Formula for the Dose Rate Contributing to the Maze Door of the 6 MV Treatment Room  

Park, Cheol Seo (Corporate Subsidiary Research Institute, Korea Best Engineering Co. Ltd)
Kim, Jong Eon (Department of Radiological Science, Kaya University)
Kang, Eun Bo (Department of Radiological Science, Dong-Eui Institute of Technology)
Publication Information
Journal of the Korean Society of Radiology / v.15, no.1, 2021 , pp. 85-91 More about this Journal
Abstract
The purpose of this study is to derive an equation to verify the accuracy of the dose rate for each component calculated at the measurement point outside the maze door when designing the maze door of 6 MV X-ray beam. Based on the component-specific dose rate calculation formula for the measurement point outside the maze door described in NCRP Report 151 and IAEA Safety Report Series 47, the dose rate calculation formula for each component when applying the values of the drawing-based parameters and the dose rate calculation formula for each component when applying the values of conservative parameters are derived. From the two dose rate calculation formulas for each component, the dose rate verification formula for each component at the measurement point outside the maze door was derived. The resulting dose rate verification formula for each component at the measurement point outside the maze door can be compared and analyzed whether the dose rate for each component at the measurement point outside the maze door calculated by the designer falls within the range of the dose rate obtained from the derived dose rate verification formula for each component. This verification formula is considered to be practically useful in verifying the accuracy of the dose rate for each component calculated by the designer.
Keywords
Maze door; Primary beam; Scattered ray; Secondary barrier;
Citations & Related Records
연도 인용수 순위
  • Reference
1 A. M. Morrow, "Radiation shielding and bunker design", Biomedical Journal of Scientific & Technical Research, Vol. 18, No. 1, pp. 13320-13330, 2019. http://dx.doi.org/10.26717/BJSTR.2019.18.003106   DOI
2 B. Mishra, T. Palani Selvam, P. K. Dash Sharma, "Structural shielding design of a 6 MV flattening filter free linear accelerator: Indian Scenario", Journal of Medical Physics, Vol. 42, No. 1, pp. 18-24, 2017. http://dx.doi.org/10.4103/jmp.JMP_99_16   DOI
3 NCRP Report No. 151, "Structural shielding design and evaluation for megavoltage X- and gamma-ray radiotherapy facilities", National Council on Radiation Protection & Measurements, 2005.
4 Safety Reports Series No. 47, "Radiation protection in the design of radiotherapy facilities", International Atomic Energy Agency, 2006.
5 P. H. Mcginley, M. S. Miner, "A method of eliminating the maze door of medical accelerator rooms", Radiation Protection Management, Vol. 12, No. 5, pp. 29-37, 1995.
6 G. A. Ezzell, "Shielding evaluation and acceptance testing of a prefabricated, modular, temporary radiation therapy treatment facility", Journal of Applied Clinical Medical Physics, Vol. 5, No. 4, pp. 120-125, 2004. http://dx.doi.org/10.1120/jacmp.v5i4.2025   DOI
7 M. F. Uddin1, M. M. Ahasan, R. Khatun, S. Akter, H. M. Jamil, A. N. Monika, M. A. Rahman, "Shielding design basis and its calculation of high energy medical linac installed in bangladesh atomic energy commission, bangladesh", Universal Journal of Medical Science, Vol. 25, No. 2, pp. 27-31, 2017. http://dx.doi.org/10.13189/ujmsj.2017.050202   DOI
8 M. C. Martin, "Linear Accelerator Direct Shielded Doors - An Approach for Calculating the Specialized Shielding Required Adjacent to the Door", World Congress on Medical Physics and Biomedical Engineering, IFMBE Proceedings Vol. 25, No.3, pp. 431-434, 2009. http://dx.doi.org/10.1007/978-3-642-03902-7_122   DOI
9 R. J. Barish, "Minimizing entrance door thickness for directentry radiotherapy rooms", Health Physics. Vol. 89, No. 2, pp. 168-171, 2005. http://dx.doi.org/10.1097/01.hp.0000160802.82833.9d   DOI
10 D. Followill, P. Geis, A. Boyer, "Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy", International Journal of Radiation Oncology·Biology·Physic, Vol. 38, No. 3, pp. 667-672, 1997. http://dx.doi.org/10.1016/s0360-3016(97)00012-6   DOI
11 S. Mutic, D. A. Low, E. E. Klein, J. F. Dempsey, J. A. Purdy, "Room shielding for intensity-modulated radiation therapy treatment facilities", International Journal of Radiation Oncology·Biology·Physic, Vol. 50, No. 1, pp. 239-241, 2001. http://dx.doi.org/10.1016/s0360-3016(01)01463-8   DOI
12 J. E. Rodgers, "Radiation therapy vault shielding calculational methods when IMRT and TBI procedures contribute", Journal of Applied Clinical Medical Physics, Vol. 2, No. 3, pp. 157-164, 2001. http://dx.doi.org/10.1120/jacmp.v2i3.2609   DOI