Evaluation of Targeting Using Marker Seed Phantom |
Jang, Eun-Sun
(Department of Radiation Oncology, Kosin University Gospel Hospital)
Jeong, Bong-Jae (Department of Radiological Science of Korea International University) Im, In-Chul (Department of Radiological Science, Dongeui University) Kang, Su-Man (Department of Radiation Oncology, Kosin University Gospel Hospital) |
1 | Rowbottom CG, Jaffray DA : Development of an integral system test for image-guided radiotherapy. Med Phys, Vol.31, PP.3500-3505, 2004 DOI ScienceOn |
2 | Sharpe MB, Moseley DJ, Purdie TG, Islam M, Siewerdsen JH, Jaffray DA : The stability of mechanical calibration for a kv cone beam computed tonography system integrated with liner accelerator. Med Phys, Vol.33, PP.136-144, 2006 DOI ScienceOn |
3 | Yoo S, Kim GY, Hammoud R, et al : A quality assurance program the on-board imager. Med Phys, Vol.33, PP.4431-4447, 2006 DOI ScienceOn |
4 | Ford EC, Chang J, Muller K, et al : Cone-beam CT with mega voltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer. Med Phys, Vol.29, PP.2913-2924, 2002 DOI ScienceOn |
5 | Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA : Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiar Oncol Biol Phys, Vol.53, PP.1337-1349, 2002 DOI ScienceOn |
6 | Ding GX, Dugan DM, Coffey CW : Characteristics of kilovoltage x-ray beams used for cone-beam computer tomography in radiation therapy. Phys Med Biol, Vol.52, PP.1595-1615, 2007 DOI ScienceOn |
7 | Schewe JE, Lam KL, Balter JM, Ten Haken RK : A room-based diagnostic imaging system for measurement of patient setup. Med Phys, Vol.25, PP.2385-2387, 1998 DOI ScienceOn |
8 | Cheong KH, Suh TS, Cho BC, et al : Analysis of uncertainties due to Digitally reconstructed radiographic (DRR) image quality in 2D-2D matching between DRRs and kv x-ray image from the On-Board Imager (OBI). Kor J Med Phys, Vol.17, PP.67-76, 2006 |
9 | Cheong KH, Cho BC, Kang SK, et al : Develoment of quality assurance program for the On-Board Imager isocenter accuracy with gantry rotation. Kor J Med Phys, Vol.17, PP.212-223, 2006 |
10 | Cho Y, Moseley DJ, Siewerdsen JH, Jaffray DA : Actecura technique for complete geometric calibaliion of cone-beam computed tomography systems. Med Phys, Vol.32, PP.968-983, 2005 DOI ScienceOn |
11 | Yang Y, schreibmann E, Li T, Wang C, Xing L : Evalution of on-board kv cone-beam computed tomography-base dose calculations. Phys Med Biol. Vol.52, PP.685-705, 2007 DOI ScienceOn |
12 | McBain CA et al : X-ray volumetric imaging in image-guided adiotherapy: the new standard in on-treatmenit maging. Int J Radiat Oncol Biol Phys, Vol.64, PP.625-34, 2006 DOI ScienceOn |
13 | Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA :A performance comparison of flat-panel imager-based MV and KV cone-beam CT. Med Phys, Vol.29, PP.967-975, 2002 DOI ScienceOn |
14 | Sorcini B, Tilikidis A : Clinical application of image-guided radio therapy, IGRT (on the varian OBI platform)cancer radiother. Vol.10, PP.252-7, 2006 |
15 | On- Board Imager Customer Acceptance Procedure, Revision F, Varian Medical Systems, Palo Alto, USA |
16 | Ding GX, Dugan DM, Coffey CW : Characteristics of kilovoltage x-ray beams used for cone-beam computer tomography in radiation therapy. Phys Med Biol, Vol.52, PP.1595-1615, 2007 DOI ScienceOn |
17 | Siewerdsen JH, Daly M, Bakhtiar B, Moseley DJ, Richard S, Keller H, Jaffary DA : A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam computed tomography. Med Phys, Vol.33, PP.87-97, 2006 |
18 | Siewerdsen JH, Jaffray DA : Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter. Med Phys, Vol.28, PP.220-31, 2000 |