Browse > Article
http://dx.doi.org/10.17946/JRST.2016.39.1.11

Characterization of the Neutron for Linear Accelerator Shielding Wall using a Monte Carlo Simulation  

Lee, Dong Yeon (Dept. of Radiation Oncology, Dongnam Inst. of Radiological & Medical Scienc)
Park, Eun Tae (Dept. of Radiation Oncology, Inje University Busan Paik Hospital)
Kim, Jung Hoon (Dept. of Radiologic Science, College of Health Sciences, Catholic University of Pusan)
Publication Information
Journal of radiological science and technology / v.39, no.1, 2016 , pp. 89-97 More about this Journal
Abstract
As previous studies to proceed with the evaluation of the radioactive at linear accelerator's shielding concrete wall. And the shielding wall was evaluated the characteristics for the incoming neutron. As a result, the shielding wall is the average amount of incoming neutrons 10 MV 4.63E-7%, 15 MV 9.69E-6%, showed the occurrence of 20 MV 2.18E-5%. The proportion of thermal neutrons of which are found to be approximately 18-33%. The neutron generation rate can be seen as a slight numerical order. However, in consideration of the linear accelerator operating time we can not ignore the effects of neutrons. Accordingly radioactive problem of the radiation shield wall of the treatment room will be this should be considered.
Keywords
Linear Accelerator; Neutron; Simulation; Radioactive;
Citations & Related Records
Times Cited By KSCI : 5  (Citation Analysis)
연도 인용수 순위
1 Eun Tae Park : Study on the Characteristics of Photoneutron Produced in Medical Linear Accelerators, Dept. of Radiological Science, Graduate School, Catholic University of Pusan, 2015.
2 Dong Wook Kim, Myong Geun Yoon, Sung Yong Park, Se Byeong Lee, et al. : Comparison of Helical TomoTherapy with Linear Accelerator Base Intensity-modulated Radiotherapy for Head & Neck Cases, Korean Society of Medical Physics, 19(2), 89-94, 2008.
3 NCRP Report No. 79 : Neutron Contamination From Medical Electron Accelerators, 1984.
4 W.L.Huang, Q.F.Li, Y.Z.Lin, Q.Su, Y.S.Luo : Measurements of phononeutrons produced by a 15 MeV electron linac for radiography applications., Nucl. Instr. and Meth. in Phy. Res. B, 251, 361-366, 2006.   DOI
5 NCRP Report No. 151 : Radiation ,Structural Shielding Design and Evaluation for Megavoltage Xand Gamma-Ray Radiotherapy Facilities, 2005.
6 Oh Nam Yang : Study on the Photoneutron Produced in Medical Linear Accelerators : Comparison of 3DCRT and IMRT, Dept. of Radiological Science The Graduate School of Health promotion Hanseo University, 2013.
7 J.H.Chao, W.S.Liu, C.Y.Chen : Estimation of Argon-41 concentrations in the vicinity of a high energy medical accelerator, Radiation Measurements, 42 1538-1544, 2007.   DOI
8 Sang Koo Kang, Sung Hwan Ahn, Chong Yeal Kim : A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method, Korean Society of Radiological Science, 34(1), 43-50, 2011.
9 Cheol Soo Park, Cheong Hwan Lim, Hong Ryang Jung, Seong Soo Shin : A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy, Korean Society of Radiological Science, 34(4), 415-427, 2008.
10 IAEA : Safety Standard Series No. WS-G-2.2, Decommissioning of Medical, Industrial and Research Facilities, 1999.
11 IAEA : Safety Report Series No.47 Radiation Protection in the Design of Radoitherapy Facilities, 2006.
12 Korea Atomic Energy Research Institute : Shielding Technology for High Energy Radiation Production Facility, 2004.
13 Los Alamos National Laboratory : User's manual version 2.5.0, LANL, 2005.
14 Herman Cember, Thomas E. Johnson : Introduction to Health Physics 4th edition., Mv Graw Hill, 2006.
15 Lee Jeong Ok, Jeong Dong Hyeok : Calculation of Energy Spectra for 6 MeV Electron Beam of LINAC Using MCNPX, Korean Society of Medical Physics, 17(4), 224-231, 2006.
16 A.Baumgartner, A.Steurer, F.Maringer : Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: Simplified estimates with PENELOPE Monte Carlo models, Applied Radiation and Isotope 67(11) 2007-2012, 2009.   DOI
17 A.Mesbahi, M.Fix, M.Allahverdi et al. : Monte Carlo calculation of Varian 2300C/D Linac photon beam Characteristics: a comparison between MCNP4C, GEANT3 and measurements, Applied Radiation and Isotopes, 62(3) 469-477, 2005.   DOI
18 Jeong Ok Lee, Dong Hyeok Jeong, Kang Jeong Ku : Neutron Generation from a 24 MV Medical Linac, Korean Society of Medical Physics, 16(2), 97-103, 2005.