Abstract
During the maintenance period at Korean nuclear power plants, internal exposure of radiation workers occurred by the inhalation of $^{131}I$ released to the reactor building when primary system was opened. The internal radioactivity of radiation workers contaminated by $^{131}I$ was immediately measured using a whole body counter and the whole body counting was performed again after a few days. In this study, the intake estimated from the record history of entrance to radiation control areas and the measurement results of air sampling for $^{131}I$ in those areas, were compared with that from the results of whole body counting. As a result, it was concluded that the intake estimation using whole body counting and air sampling showed similar results.
Keywords
$^{131}I$; Internal Exposure; Whole Body Counter; Radioactive Concentration in Air; Intake Estimation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 한국수력원자력(주). 내부 방사능 오염 측정 및 평가 검증체계 기술개발. I05NJ14. 2006
2 김희근, 공태영. 전신계측기를 이용한 원전종사자의 방사성 오염위치 확인과 내부방사능측정 개선에 관한 연구 Journal of Radiation Protection, 2009 March;34(1):37-42
3 Kong TY, Kim HG. Improvement to Whole-Body Counting Procedures at Nuclear Power Plants. Radiation Protection Dosimetry, 2009 January;133(2):89-96   DOI   ScienceOn
4 International Commission on Radiological Protection. Individual Monitoring for Intakes of radionuclides by Workers:Design and Interpretation, ICRP Publication 54. 1987
5 한전전력연구원. 내부피폭 선량평가 및 방사선피폭저감 기술개발 관련 세미나 결과보고서, TC.02.NE07.W2003.158, 2003
6 한국수력원자력(주). 2008년도 원자력발전소 방사선관리연보. 2008
7 Canberra. Model 2250 FASTSCAN, High-Throughput Whole Body Counter. 2002
8 United States Nuclear Regulatory Commission. Regulatory Guide 8.20, Application of Bioassay for I-125 and I-131,USNRC. 1979
9 한국수력원자력(주) 원자력교육원. 제21기 방사선(안전, 방재)관리자. 2005
10 American National Standard Institute. Performance Criteria for Radiobioassay. ANSI HPS N13.30. 1996
11 한전전력연구원. 일본 방사선총합연구소(NIRS)소속 방사선량평가 전문가 초청결과 보고서, TM.02NE07.P2003.062, 2003
12 한국수력원자력(주). 원자력 발전소 표준기술행정절차서, 내부피폭 방사선량측정 및 평가, 표준기행 방사선-06. 2003
13 International Commission on Radiological Protection.Individual Monitoring for Internal Exposure of Workers Replacement of ICRP Publication 54, ICRP Publication78. Pergamon Press. 1997
14 Canberra. Abacos Plus Body Burden System Operation, SU-425-4. 2003
15 김희근, 요오드-131 흡힙에 따른 내부피폭 선량평가 방법의 고찰. 2003 KINS 방사선안전평가 심포지엄. 교육문화회관. 2003
16 한전전력연구원. 내부피폭 선량평가 코드(KIDAC) 섭취잔류분율 및 화학형 개정보고서, TM.02NE07.P2003.168, 2003