Browse > Article
http://dx.doi.org/10.5916/jkosme.2007.31.4.370

A Measurement Study on the Thermal Conditions in Cabins of a Long Cruise Passenger ship in the Winter  

Hwang, Kwang-Il (한국해양대학교 기계.정보공학부)
Woo, Sang-Woo (한국해양대학교 대학원 냉동공조공학)
Shim, Jae-Gun (한국해양대학교 기계.정보공학부)
Park, Min-Kang (한국해양대학교 기계.정보공학부)
Moon, Tae-Il (한국해양대학교 기계.정보공학부)
Abstract
The purpose of this study is to measure the thermal conditions of the various cabins in a long cruise passenger ship which is an integration of the high level technological know-how. We did an experiment and found out the following problems. (1) The temperature from the damper is stable but the humidity varies lower. (2) Comparing A deck-located cabins to B deck-located cabins, A-deck located cabins' temperatures are higher because of the 24% more air supply. (3) More influences from outdoor climate makes the temperature of the outside cabin lower than the inside cabin. (4) In some cabins, there are vertical temperature differences of $4{\sim}6^{\circ}C$. (5) And $2{\sim}4^{\circ}C$ temperature differences are occurred at between 2-story bed. (6) Repeatability of measurement results are confirmed by 2 times measurements.
Keywords
Cruiser; Cabin; Thermal Conditions;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Clarkson, World Shipyard Monitor (2005-2006)
2 富岡節,船用冷凍機と空氣調和,成山堂書店, 1978. 9
3 日本造船學會, 舶用空氣調和裝置計劃基準․ 船泊の通氣裝置設計基準, 海文堂, 1970. 9
4 장미숙, 조용진, 김광수, 박병재, 고창두, 해양연구원 연구선의 선실 환경 평가, 대한조선학회논문집, 2005
5 도근영, 송화철, 해상호텔의 공조설비에 관한 연구, 2003년도추계학술발표대회논문집, 한국생태환경건축학회, 2003.11
6 이영삼, 김영모, 여객선, 해인출판사,2002.3
7 한국조선공업협회(http://www.koshipa.or. kr), 조선자료집
8 장미숙, 고창두, 문일성, 이춘주, 김상현, 함정선내의 온열요소에 대한 조사 연구, 한국해양환경공학회지, Vol.8, No.1, pp.31-38, 2005.2