Browse > Article

Setting Time and Strength of Slip-form Method Applied Caisson in Low-temperature Period  

Kim, Bong-Joo (공주대학교 천안공과대학 건축공학부)
Kim, Jae-Hun (경민대학 실용건축과)
Kim, Chan-Soo (현대건설 기술연구소)
Jo, Ho-Kyoo (현대건설 기술연구소)
Publication Information
Abstract
In the harbor construction work, caisson is made by slip-form method and curing temperature of caisson concrete need heating in the low-temperature. To get the setting time and compression strength of slip-form method applied caisson at various curing temperature. The curing temperature is divided to the temperature of slip-form and the temperature of second curing curtain. In consideration of setting time, compression strength of concrete and form-removal time, the best temperature is $25^{\circ}C$ at 6 hours slip-form curing time.
Keywords
slip-form; curing temperature; curing time; form-removal time;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김무한외 4인 (2003). 적산온도 방법에 의한 강도예측모델 개발 및 건설생산현장에서의 강도관리에 관한 연구, 한국콘크리트학회 논문집, 한국콘크리트학회, Vol.15 NO.1 pp. 87-94
2 지남용외 2인 (2003). 성숙도 개념을 이용한 한중콘크리트의 양생관리 프로세스에 관한 연구, 대한건축학회논문집(구조계) , 대한건축학회, Vol.19, No. 10, .pp 51-58
3 ACI Committee 347. Guide to Formwork for Concrete (ACI 34 7R-94)
4 이준구외 4인 (2004). 적산온도에 의한 동절기 콘크리트의 품질관리, 한국콘크리트학회 가을 학술발표회 논문집, 한국콘크리트학회, Vol.16 No.2,.pp 245-248
5 A.M.Neville, Propertise of Concrete 4th pp. 370-374, 390-394
6 ACI Committee 308. Standard Practice for Curing Concrete, (ACI 308-92)