Browse > Article
http://dx.doi.org/10.5806/AST.2015.28.6.425

Development of a cholesterol biosensor modified with carbon nanotube  

Kim, Haidong (Department of Chemistry, Kyung Hee University)
Publication Information
Analytical Science and Technology / v.28, no.6, 2015 , pp. 425-429 More about this Journal
Abstract
A cholesterol biosensor was developed using a modified carbon electrode with carbon nanotubes. The disposable cholesterol biosensor was modified with carbon nanotubes to enhance electron transfer during the enzymatic reaction of cholesterol. Cholesterol oxidase and peroxidase, with potassium ferrocyanide as a mediator, were immobilized on a screen-printed carbon nanotube electrode. The electrochemical cholesterol biosensor developed using carbon nanotubes showed a rapid and reliable signal for measuring total cholesterol. The cholesterol sensor showed a linear response in 5 seconds with a small volume (0.5 μL) in the range of 100~400 mg/dL, with a coefficient of variation of 4.0%.
Keywords
cholesterol; point-of-care; blood test;
Citations & Related Records
연도 인용수 순위
  • Reference
1 J. Wang, Electroanal., 17, 7-14 (2005).   DOI
2 H. Chengguo and H. Shenghui, J. Sensors, 1-40 (2009).
3 J. L. Yi, D. K. Jung and Y. P. Jae, J. Kor. Phys. Soc., 54, 1769-1773 (2009).   DOI
4 F. Ricci and G. Palleschi, Biosens. Bioelectron, 21, 389-407 (2005).   DOI
5 S. Park, H. Boo and T. D. Chung, Anal. Chim. Acta, 556, 46-57 (2006).   DOI
6 Y. Wang, X. Hui, J. Zhang and L. Guang, Sensors, 8, 2043-2081 (2008).   DOI
7 M. Barbadillo, E. Casero, Petit-Dominguez, M. D., L. Vazquez, F. Pariente and E. Lorenzo, Talanta, 80, 797-802 (2009).   DOI
8 Y. Y. Hosokawa, H. Hakamata, T. Murakami, S. Aoyagi, M. Kuroda, Y. Mimaki, Y. A. Ito, S. Morosawa and F. Kusu, Electrochim. Acta, 54, 6412-6416 (2009)   DOI
9 B. Canabate-Diaz, C. A. Segura, A. F. Gutierrez, V. A. Belmonte, F. A. Garrido, V. J. L. Martinez and M. J. Duran, Food Chem, 102, 593-598 (2007).   DOI
10 C. K Pires, B. F. Reis, C. X. Galhardo and P. B. Martelli, Anal. Lett., 36, 3011-3024 (2003).   DOI
11 J. B. Claver, J. A. Cabello, J. M. Sanfrutos, A. M. Fernandez, M. C. V. Miron, F. S. Gonzalez and L. F. C. Vallvey, Anal. Chim. Acta, 754, 91-98 (2012).   DOI
12 O. Turkarslan, S. K. Kayahan and L. Toppare, Sens. Actuators B, 136, 484-488 (2009).   DOI
13 G. R. Warnick, M. M. Kimberly, P. P. Waymack and E. T. Leary, Labmedicine, 39(8), 481-490 (2008).
14 S. K. Arya, M. Datta and B. D. Malhotra, Biosens. Bioelectron., 23, 1083-1100 (2008).   DOI
15 M. Q. Israr1, K. Hasan, J. R. Sadaf, I. Engquist, O. Nur, M. Willander and B. Danielsson, J. Biosens Bioelectron, 2(3), 1000109 (2011).