Browse > Article
http://dx.doi.org/10.5806/AST.2011.24.2.127

Monitoring of preservatives in herbal liquid preparations  

Jeon, Jong-Sup (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Jo, Hyun-Ye (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Kim, Bum-Ho (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Cho, Sang-Hun (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Park, Shin-Hee (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Kim, Young-Sug (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Yoon, Mi-Hye (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Lee, Jeong-Bok (Pharmaceutical Chemistry Team, Gyeonggi-do Institute of Health and Environment)
Publication Information
Analytical Science and Technology / v.24, no.2, 2011 , pp. 127-134 More about this Journal
Abstract
Quantitative HPLC analysis for the determination of in herbal liquid preparations was improved from the general test method besides the Korean Pharmacopeia. Good chromatographic separation of samples containing parabens, interferences, and other pharmaceutical excipients was effectively achieved by using acetonitrile water (containing 1% glacial acetic acid) mixture (30:70 v/v) as mobile phase. To monitor preservatives (benzoic acid, parabens, sorbic acid, dehydroacetic acid, and their salts) in herbal liquid preparations, a group of 47 samples was divided into two different group: preservative labeled group and unlabeled group. From the results, the contents of preservatives in 31 samples of preservative labeled group fell under KFDA regulations, and the contents of dehydroacetic acid in 6 samples of preservative labeled group were not followed by KFDA regulations. Preservatives were detected in 3 samples out of 10 samples in preservative unlabeled group.
Keywords
herbal liquid preparations; pharmaceutical excipients; preservatives;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 FDA CEDER. Validation of chromatographic methods, Available from http://www.fda.gov/downloads/Drugs/Guidance Compliance RegulatoryInformation/Guidances/UCM134409.pdf, Accessed Dec. 02 (2010).
2 USDA. Determination of Benzoic acid, Sorbic aicd, and Methyl, Ethyl, Propyl, and Butyl Parabens by HPLC, Available from http://www.fsis.usda.gov/PDF/CLG_BSP_01.pdf, Accessed Dec. 02 (2010).
3 Chen, B. H. and Fu, S. C., Chromatographia, 14, No. 1/2, 43-50(1995).
4 Memon, N., Bhanger, M.I. and Khuhawer, M.Y., J. Sep. Sci., 28, 635-638(2005).   DOI   ScienceOn
5 Korea Food and Drug Administration, Korean Pharmacopoeia, Ninth Edition (2007).
6 Baldrick, P., Regul. Tox. Pharm., 32, 210-218(2000).   DOI   ScienceOn
7 Ochiai, N., Sasamoto, K., Takino, M., Yamashita, S., Daishima, S., Heiden, A. C. and Hoffmann, A., Anal Bioanal Chem, 373, 56-63(2002).   DOI   ScienceOn
8 Korea Food and Drug Administration, Korean Food Code (2010).
9 Korea Food and Drug Administration, Optimization Plan of Use Standard for Preservatives, The annual report of KFDA (2009).
10 WHO, Benzoic acid and sodium benzoate. Concise International Chemical Assessment Document 26. World Health Organization, Geneva, Switzerland (2000).
11 Soni, M. G., Carabin, I. G. and Burdock, G. A., 43, 985-1015(2005).
12 Oishi, S., Food Chem. Toxicol., 40, 1807-1813(2002).   DOI   ScienceOn
13 Routledge, E. J., Rarker, J., Odum, J., Ashby, J. and Sumpter, J. P., Toxicol. Appl. Pharmacol., 153, 12-19 (1998).   DOI   ScienceOn
14 Jeong, I. H., Kim, J. H., Jeon, J. S., Cho, S. H., Par, S. H., Jo, H. Y. and Kim, Y. S., J. Fd Hyg. Safety, 25(3), 232-237(2010).
15 Korea Food and Drug Administration, Notice No. 2010-103 (2010).
16 Kim, M. C., Park, H. K., Hong, J. H., Lee, D. Y., Park, J. S., Park, E. J., Kim, J. W., Song, K. H., Shin, D. W., Mok, J. M., Lee, J. Y. and Song, I. S., Korean J. Food. Sci. Technol., 31(5), 1144-1152(1999).
17 Korea Food and Drug Administration, Notice No. 2010-82 (2010).
18 Lee, H. J., Ahn, H. J., Kang, C. S., Choi, J. C., Choi, J. C., Lee, K. G., Kim, J. I. and Kim, H. Y., Food Control, 21, 217-220(2010).   DOI   ScienceOn
19 European Medicine agency, Guideline On Excipients In The Dossier For Application For Marketing Authorisation Of A Medicinal Product, Available from http://www.ema.europa.eu/docs/en_GB/document_library/Scientific_guideline/2009/09/WC500003382.pdf. Accessed Dec. 02(2010).
20 Korea Food and Drug Administration, Notice No. 2010-71 (2010).
21 Shabir, G. A., J. Pharm. Biomed. Anal., 34, 207-213(2004).   DOI   ScienceOn
22 Memon, N., Bhanger, M. I. and Khuhawer, M. Y., J. Sep. Sci., 28, 635-638(2005).   DOI   ScienceOn
23 Mikami, E., Goto, T., Ohno, T., Matsumoto, H. and Nishida. M., J. Pharm. Biomed. Anal., 28, 261-267 (2002).   DOI   ScienceOn
24 Lee, M. R., Lin, C. Y., Li, Z. G. and Tsai, T. F., J. Chromatogr A., 1120, 244-51(2006).   DOI   ScienceOn
25 Korea Food and Drug Administration, Notice No. 2008-76 (2008).
26 Li, XQ., Ji, C., Yong, W., Ling, Y., Yang, M. L. and Chu, X. G., Chromatographia, 68, 57-63(2008).