Browse > Article

Analytical method of PCDDs/PCDFs in blood using NIST SRM 1589a  

Shin, Sun Kyoung (National Institute of Environmental Research)
Park, Seok Un (National Institute of Environmental Research)
Kim, Tae Seung (National Institute of Environmental Research)
Publication Information
Analytical Science and Technology / v.18, no.6, 2005 , pp. 559-567 More about this Journal
Abstract
For the analytical method of PCDD/Fs in blood, which have been issued recently, SRM 1589a of NIST(National Institute of Standards and Technology) was used and a practical analytical method of PCDD/Fs in blood was presented through comparison of methods of Canada and Japan. The proposed method used alkali-digestion extraction for removal of the lipid effectively using two capillary columns. The limit of quantification of TeCDD/DF and PeCDD/DF was 1 pg/g-lipid, HxCDD/DF and HpCDD/DF was 2 pg/g-lipid, OCDD/DF was 4 pg/g-lipid. With consideration the range of detected concentration, calibration standards were presented as $CS_L$(0.1~1), $CS_1/2$(0.25~2.5), $CS_1$(0.5~5.0), $CS_2$(2~20), $CS_3$(10~100).
Keywords
Serum; PCDDs/PCDFs; Analytical Method; SRM;
Citations & Related Records
연도 인용수 순위
  • Reference
1 D. G. Patterson, J. S. Holler, S. J. Smith, J. A. Liddle, E. J. Sampson and L. L. Needham, Human adipose data for 2,3,7,8-tetrachlorodibenzo-p-dioxin in certain U.S. samples, Chemosphere, 15(9-12), 2055-2060(1986)   DOI   ScienceOn
2 Y. Okumura, Y. Yamashita, Y. Kohno and H. Nagasaka, Historical trends of PCDD/Fs and CO-PCBs in a sediment core collected in Sendai Bay, Japan, Water Research, 38(16), 3511-3522(2004)   DOI   ScienceOn
3 http://www.nist.gov (National Institute of Standards and Technology)
4 내분비계장애물질측정분석방법, 국립환경과학원, 2002
5 John J. Ryan, Henry B. S. Conacher, Luz G. Panopio, Benjamin P. -Y. Lau and Jacques A. Hardy, Yoshito Masuda, Gas chromatographic separations of all 136 tetra- to octachlorinated dibenzo-p-dioxins and polychlo-rinated dibenzofurans on nine different stationary phases, Journal of Chromatography, 541, 131-183 (1991)   DOI   ScienceOn
6 Canada EPA, A Comprehensive Multiresidue Ulta-Trace Analytical Method, Based on HRGC/HRMS in Six different Environmental Matrix, 2001
7 K. Olile, P. L. Vermeulen and O. Hutzinger, Chloro-dibenzo-p-dioxins and chlorodibenzofurans are trace components of fly ash and flue gas of some municipal incinerators in The Netherlands, Chemosphere, 6(8), 455-459(1977)   DOI   ScienceOn
8 Adrian Covaci, John Jake Ryan, Paul Schepens, Patterns of PCBs and PCDD/PCDFs in chicken and pork fat following a Belgian food contamination incident, Chemosphere, 47(2), 207-217(2002)   DOI   ScienceOn
9 Stockholm Convention on Persistent Organic Pollutants (http://www.pops.int)
10 국립환경연구원, 혈액 중 다이옥신류 분석방법, 2005
11 R. J. Kociba, D. G. Keyes, J. E. Beyer, R. M. Carreon, C. E. Wade, D. A. Dittenber, R. P. Kalnins, L. E. Frauson, C. N. Park, S. D. Barnard et al., Results of a two-year chronic toxicity and oncogenicity study of 2,3,7,8-tetrachlorodibenzo-p-dioxin in rats, Toxicology and Applied Pharmacology, 46(2), 279-303(1978)   DOI   ScienceOn
12 일본 환경성, ダイオキシン類測定暫政マニユアル, 2000
13 WHO, IPCS 205, Polychlorinated dibenzo-p-dioxins and Dibenzofurans, 1998
14 환경부, 폐기물공정시험방법(PCBs), 2004
15 포항공과대학교, HRGC/HRMS를 이용한 혈액 중 다이옥신류의 측정분석, 2003