|
1 |
Evaluation of Minimum Spiral Reinforcement Ratio of Circular RC Columns
Kim, Young-Seek;Kim, Hyeong-Gook;Park, Cheon-Beom;Kim, Sang-Woo;Kim, Kil-Hee;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.1-9,
|
|
2 |
Fatigue Durability Evaluation of Refraction Expansion Joints
Na, Jun-Su;Lee, Ta;Han, Eui-Seok;Sung, Won-Kyu;Lee, Jong-Suk;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.10-15,
|
|
3 |
Investigation of Optimal Outrigger Location of High-rise Offset Outrigger System
Kim, Hyong-Kee;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.16-24,
|
|
4 |
A Study of Evaluation System of NATM Tunnel using Delphi and AHP
Park, Kwang-Rim;Chung, Jee-Seung;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.25-34,
|
|
5 |
An Examination of the Minimum Reinforcement Ratio for Reinforced Concrete Flexural Members
Choi, Seung-Won;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.35-43,
|
|
6 |
Study on Flexural Strength of Wide Composite Beam for Long Span and Saving Story height
Choi, Yun-Cheul;Park, Keum-Sung;Lee, Sang-Sup;Choi, Hyun-Ki;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.44-51,
|
|
7 |
Application Properties of Slag Concrete in Winter Season
Yoo, Jo-Hyeong;Kim, Woo-Jae;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.52-58,
|
|
8 |
Influence of Earthquake Shape on the Dynamic Behavior of Fluid in a Rectangular Structure
Park, Gun;Hong, Ki-Nam;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.59-66,
|
|
9 |
Shear Performance of Large-Diameter Composite PHC Pile Strengthened by In-Filled Concrete and Shear Reinforcement
Hyun, Jung-Hwan;Bang, Jin-Wook;Kim, Yun-Yong;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.67-73,
|
|
10 |
The Fundamental Properties of High Fluidity Mortar with Activated Ternary Blended Slag Cement
Bae, Ju-Ryong;Kim, Tae-Wan;Kim, In-Tae;Kim, Hyoung-Seok;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.74-82,
|
|
11 |
Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period
Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.83-90,
|
|
12 |
Dynamic Characteristics of Hollow Core Slab by Vibraion Test and Modal Analysis
Kang, Kyoung-Soo;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.91-97,
|
|
13 |
Tensile Behavior of Hybrid Fiber Reinforced Cement Composite According to the Hooked Steel Fiber and Polyvinyl Alcohol Fiber Blending Ratio and Strain Rate
Son, Min-Jae;Kim, Gyu-Yong;Lee, Sang-Kyu;Kim, Hong-Seop;Nam, Jeong-Soo;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.98-105,
|
|
14 |
Estimation of Shear Strength Along Concrete Construction Joints Considering the Variation of Concrete Cohesion and Coefficient of Friction
Yang, Keun-Hyeok;Kwon, Hyuck-Jin;Park, Jong-Beom;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.106-112,
|
|
15 |
RSM-based Practical Optimum Design of TMD for Control of Structural Response Considering Weighted Multiple Objectives
Do, Jeongyun;Guk, Seongoh;Kim, Dookie;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.113-125,
|
|
16 |
Structural Safety Evaluation by Analysis of Pressure Variation Characteristics of Small Hydro Power Hydraulic Turbine Blades in Sewage Treatment Plant
Park, Yoo-Sin;Kim, Ki-Jung;Youn, Byong-Don;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.126-131,
|
|
17 |
Evaluation of the Properties of an Environment-Friendly De-icing Agent Based on Industrial By-Products
Heo, Hyung-Seok;Lee, Byung-Jae;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.132-139,
|
|
18 |
An Experimental Study on the Application of LIBS for the Diagnosis of Concrete Deterioration
Woo, Sang-Kyun;Chu, In-Yeop;Youn, Byong-Don;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.140-146,
|
|
19 |
Code Change for using the High-Strength(550 MPa) Headed Deformed Bars of Large-Sized Diameter(57 mm) in Concrete Containments
Lee, Byung-Soo;Lim, Sang-Jun;Yun, Hyun-Do;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.147-161,
|
|
20 |
Effects of CNT Additions on Mechanical Properties and Microstructures of Cement
Oh, Sungwoo;Oh, Kyeong-seok;Jung, Sang-hwa;Chung, Wonseok;Yoo, Sung-won;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.162-168,
|
|
21 |
Estimation on Filling Performance of Thixotropic Grout for Increasing Front-Water Depth of Gravity-Type Quay Wall
Jang, Kyong-Pil;Ryu, Yong-Sun;Kwon, Seung-Hee;Han, Woon-Woo;Oh, Myong-Hak;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.169-177,
|
|
22 |
Tensile Behavior of Highly Ductile Cementitious Composites Using Normal Sand as Fine Aggregate
Lee, Bang Yeon;Kang, Su-Tae;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.178-184,
|
|
23 |
Quantitative Fire Risk Assessment and Counter Plans Based on FDS and GIS for National Road Bridges
Ann, Ho June;Park, Cheol Woo;Kim, Yong Jae;Jang, Young Ik;Kong, Jung Sik;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.185-195,
|
|
24 |
Evaluation on Structural Performance of Precast Bridge Deck Joint using HSFRC
Lee, Han-Joo;Chung, Chul-Hun;Shin, Dong-Ho;Park, Se-Jin;Kim, In-Gyu;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.196-205,
|
|
25 |
An Experimental Study of Mechanical Properties of High-strength Concrete
Yang, In-Hwan;Hwang, Chul-Sung;
/
Korea Institute for Structural Maintenance Inspection
, v.21, no.6, pp.206-215,
|
|