Acknowledgement
본 연구는 보건복지부의 재원으로 한국보건산업진흥원의 보건의료기술연구개발사업 지원을 받아 수행된 연구임(과제고유번호: HJ22C0003).
References
- Ministry of Health and Welfare. 2020. Registration status of persons with disabilities, http://www.mohw.go.kr/. [accessed: 17-6-2024]
- B. E. Lawson, H. A. Varol, A. Huff, E. Erdemir, and M. Goldfarb, "Control of stair ascent and descent with a powered transfemoral prosthesis," IEEE Trans. of Rehabilitation Engineering, vol. 21, no. 3, pp. 446-473, 2013, doi: 10.1109/TNSRE.2012.2225640.
- G. Y. Gyeong, J. G. Kim, and Y. S. Lee, "The Structure of a Powered Knee Prosthesis based on a BLDC Motor and Impedance Control using Torque Estimation on Free Swing," Journal of Institute of Control Robotics and Systems, vol. 21, no. 5. pp. 407-412, 2015, doi: 10.5302/j.icros.2015.15.9018.
- J. W. Lee, H. S. Woo, D. Y. Ahn, M. Jo, H. Yi, and K. Y. Kim, "Development of an Electronically Controlled Knee-Type Prosthetic Leg with a 4-Bar Linkage Structure for Lower Limb Amputee," The Journal of Korea Robotics Society, vol. 19, no. 2, pp. 159-168, doi: 10.9728/dcs.2018.19.7.1405.
- W. Alcocer, L. Vela, A. Blanco, J. Gonzalez, and M. Oliver,"Major Trends in the Developmentof Ankle Rehabilitation Devices," Int. J. DYNA, vol. 79, no. 176, pp. 45-55, 2012.
- Ottobock shuttle lock device, Model: 6A20=10 https://www.ottobock.com/ [accessed:29-May-2024].
- J. S. Song, S. M. Lee, and G. C. Cha, "Study on Developments of Prosthetic Socket and Locking Device of New Material," Journal of Korean Society for Prosthetics and Orthotics, vol. 9, no. 1, pp. 36-43, 2015.
- M. S. Son,"Manufacturing a Trans-tibial Prosthesis with Silicone Liner and Shuttle Lock,"Journal of Korean Society for Prosthetics and Orthotics, vol. 6, no. 1, pp. 36-43, 2012.
- C. H. Song, "Fabricating Method Using Custom Liner and Correct Application," Journal of Korean Society for Prosthetics and Orthotics, vol. 6, no. 1, pp. 44-52, 2012.
- Dynamics simulation program, https://hexagon.com/products/product-groups/computer-aided-engineering-software/adams [accessed: 17-6-2024].
- H. C. Kim, H. S. Cho, Y. H. Jang, H. J. Shin, H. S. Park, and Y. J. Cho. "Development of bio-mimetic prosthetic foot for transfemoral amputee,"Journal of Rehabilitation Welfare Engineering & Assistive Technology, vol. 17. no. 4, pp. 281-288, 2023, doi:10.21288/resko.2023.17.4.281.
- Article 163 of the Rules on Occupational Safety and Health Standards, https://www.law.go.kr, [accessed: 10-6-2024].
- Korean standard body type, https://sizekorea.kr/ [accessed: 7-6-2024].
- Neodym standard table, https://kr.misumi-ec.com/ [accessed: 17-6-2024].
- INSTRON 8511 tester, https://www.instron.com/en/products/testing-systems/out-of-production-systems/dynamic [accessed:15-6-2024].
- W. S. Seong, J. H. Kim, and D. H. Jeong, "The Reliability of the K-PEQ(Korean Prosthesis Evaluation Questionnaire) in Lower Extremity Amputees." Journal of Digital Contents Society, vol. 19 no. 7, pp. 1405-1412, 2018, doi: 10.9728/dcs.2018.19.7.1405.