DOI QR코드

DOI QR Code

Study on the Effectiveness of Radiological Technologist's Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination

어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구

  • Chang-Kyo Kwak (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • Jeong-Taek Kwon (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • Kwang-Je Lee (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • Il-Hwan Bae (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • Hye-Jung Kim (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • So-Mi Lee (Department of Radiology, Kyungpook National University Chilgok Hospital) ;
  • Do-Byung Rhee (Department of Radiology, Kyungpook National University Chilgok Hospital)
  • 곽창교 (칠곡경북대학교병원 영상의학과) ;
  • 권정택 (칠곡경북대학교병원 영상의학과) ;
  • 이광제 (칠곡경북대학교병원 영상의학과) ;
  • 배일환 (칠곡경북대학교병원 영상의학과) ;
  • 김혜정 (칠곡경북대학교병원 영상의학과) ;
  • 이소미 (칠곡경북대학교병원 영상의학과) ;
  • 이도병 (칠곡경북대학교병원 영상의학과)
  • Received : 2024.05.22
  • Accepted : 2024.06.03
  • Published : 2024.06.30

Abstract

During paranasal sinus X-ray examinations in children, the radiological technologist's thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist's could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

Keywords

References

  1. Rhee DB, Kim JK, Lee JM. A Study on the comparison of the radiation exposure dose to the image quality of phantom chest radiography using a radiographic assist device. New Physics. 2018;68(7):801-11. DOI: https://doi.org/10.3938/NPSM.68.801
  2. Rhee DB, Lee SM, Choi HW, Kim JK, Lee JM. A study on chest X-ray using ancillary device for child radiography. Journal of Biomedical Engineering Research. 2018;39(1):48-54. DOI: https://doi.org/10.17946/JRST.2020.43.4.243
  3. Yoon YS, Park HM, Won JH, Song SK, Gil JW, Lee BY. Korean diagnostic reference level for general radiography and mammography in 2022. Public Health Weekly Report. 2023;16:1082-100. DOI: https://doi.org/10.56786/PHWR.2023.16.31.2
  4. ICRP. 1990 recommendations of the international commission on radiological protection. International Commission on Radiological Protection. ICRP Publication 60 Ann. ICRP, 21(1-3): 1991. Available from https://journals.sagepub.com/doi/pdf/10.1177/ANIB_21_1-3
  5. ICRP. The 2007 recommendations of the international commission on radiological protection. International Commission of Radiological Protection. ICRP Publication 103 Ann. ICRP, 37, Pergamon, Oxford; 2007. Available from https://icrp.org/docs/ICRP_Publication_103-Annals_of_the_ICRP_37(2-4)-Free_extract.pdf
  6. ICRP. 1996 recommendations of the international commission on radiological protection. International Commission on Radiological Protection. ICRP Publication 73. 1996. Available from https://journals.sagepub.com/doi/pdf/10.1177/ANIB_26_2
  7. Eo H, Gil JW, Lee BY, Lee HK. Development of diagnostic reference levels (DRL) in fluoroscopy. Public Health Weekly Report. 2021;14:1633-47. Available from https://www.phwr.org/journal/view.html?pn=search&uid=505&vmd=Full
  8. Ji MH, Gil JW, Won JH, Lee BY, Seoung YH. The nation public awareness on medical radiation using structural equations model. Public Health Weekly Report. 2023;16:1289-305. DOI: https://doi.org/10.56786/PHWR.2023.16.38.1
  9. Rhee DB, Seo SJ, Choi HW, Ko CW, Kim JK. Development of children's X-ray imaging assist device. Journal of Radiological Science and Technology. 2020;43(4):243-9. DOI: https://doi.org/10.17946/JRST.2020.43.4.243
  10. ICRP. Conversion coefficients for use in radiological protection against external radiation. International Commission of Radiological Protection. ICRP Publication 74. Oxford, Pergamon Press; 1997. Available from https://journals.sagepub.com/doi/pdf/10.1177/ANIB_26_3-4
  11. Regulla DF, Eder H. Patient exposure in medical X-ray imaging in Europe. Radiat Prot Dosimetry. 2005;114(1-3):11-25. DOI: https://doi.org/10.1093/rpd/nch538
  12. Kim, GH. Research of awareness for medical radiation safety in radiography. Journal of Radiological Science and Technology. 2018;41(3):255-60. Available from https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=49069357
  13. Nuclear Safety and Security Commission. Act on protective action guidelines against radiation in the natural environment. Article 2, Seoul, Korea; 2017. Available from https://www.nssc.go.kr/attach/namo/files/ 000001/20191206162526368_SWNZIWCO.pdf
  14. Marazziti D, Baroni S, Catena-Dell'Osso M, Schiavi E, Ceresoli D, Conversano C, et al. Cognitive, psychological and psychiatric effects of ionizing radiation exposure. Curr Med Chem. 2012;19(12):1864-9. Available from https://pubmed.ncbi.nlm.nih.gov/22376039/
  15. Tang FR, Loganovsky K. Low dose or low dose rate ionizing radiation-induced health effect in the human. J Environ Radioact. 2018;192:32-47. DOI: https://doi.org/10.1016/j.jenvrad.2018.05.018
  16. Upton AC. The dose-response relation in radiation-induced cancer. Cancer Res. 1961;21:717-29. Available from https://pubmed.ncbi.nlm.nih.gov/13779235/
  17. Rugh R. Low levels of x-irradiation and the early mammalian embryo. Am J Roentgenol Radium Ther Nucl Med. 1962;87:559-66. Available from https://api.semanticscholar.org/CorpusID:40941701
  18. Yun JH, Lee KW, Cho YK, Choi JW, Lee JI. Effective dose determination from CT head & neck region. Journal of Radiological Science and Technology. 2011;34(2):105-16. Available from https://koreascience.kr/article/JAKO201121641922069.page
  19. The Korean Society of Radiology. Radiation and human body. Pediatric radiation exposure dose. Available from http://www.radiologyinfo.or.kr/
  20. Ajou University Medical Center. Health information. 2007. Available from https://www.ajoumc.or.kr/story/board/articleView010003001.do?no=4776