DOI QR코드

DOI QR Code

Evaluation of Mechanical Joint Structural Performance through Actual Performance Testing of PC Connections

PC 접합부의 실물 성능실험을 통한 기계식이음 구조성능 평가

  • Kim, Jae Young (Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University) ;
  • Kim, Yong Nam (Mirae Structural Engineering Co., Ltd.,) ;
  • Seo, Min Jung (Mirae Structural Engineering) ;
  • Kim, Beom Jin (Jisan Group) ;
  • Kim, Sung Jig (Department of Architectural Engineering, Keimyung University) ;
  • Lee, Kihak (Deep Learning Architecture Research Center, Department of Architectural Engineering, Sejong University)
  • 김재영 (세종대학교 건축공학과 딥러닝 건축연구소) ;
  • 김용남 ((주)미래구조엔지니어링) ;
  • 서민정 ((주)미래구조엔지니어링) ;
  • 김범진 ((주)지산개발) ;
  • 김승직 (계명대학교 건축공학과) ;
  • 이기학 (세종대학교 건축공학과 딥러닝 건축연구소)
  • Received : 2023.12.29
  • Accepted : 2024.02.16
  • Published : 2024.05.01

Abstract

In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.

Keywords

Acknowledgement

본 논문은 정부(과학기술정보통신부)의 재원으로 한국연구재단(NRF-2020R1A2C2007195)과 2024년도 정부(교육부)의 재원으로 한국연구재단의 지원을 받아 수행된 기초연구사업(RS-2023-00271991)임.이에 감사드립니다.

References

  1. Bahrami S, Madhkhan M, Shirmohammadi F. Behavior of two new moment resisting precast beam to column connections subjected to lateral loading. J Eng Str. 2017 Feb;132:808-821.  https://doi.org/10.1016/j.engstruct.2016.11.060
  2. Gallegos M, Nunez E, Herrera R. Numerical study on cyclic response of end-plate biaxial moment connection in box columns. J Metals. 2020 Feb;10(4):523. 
  3. Im HJ, Park HG, Eom TS, Kang SM. Earthquake resistance of beam-column connection of precast concrete u-shaped shell construction. J Korea Concr Inst. 2010 Dec;22(6):741-751.  https://doi.org/10.4334/JKCI.2010.22.6.741
  4. Kim JS, Kwark J, Joh C, Yoo SW, Lee KC. Headed stud shear connector for thin ultrahigh-performance concrete bridge deck. J Const Steel Resea. 2015 May;108:23-30.  https://doi.org/10.1016/j.jcsr.2015.02.001
  5. Lee SJ, Hong SG, Lim WY. Seismic performance of precast concrete beam-column connections using ductile rod. J Korea Concr Inst. 2014 Dec;26(6):695-705.  https://doi.org/10.4334/JKCI.2014.26.6.695
  6. Lin Y, Chen Z, Guan D, Guo Z. Numerical study on cyclic response of end-plate biaxial moment connection in box columns. J Struc. 2021 Aug;32:1103-1114. 
  7. Nunez E, Boainy N, Gonzalez F, Torres R, Picon R, Guerrero N. Cyclic behavior of hollow section beam-column moment connection Experimental and numerical study. J Metals. 2020 Nov;10(12):1608. 
  8. Nunez E, Parraguez G, Herrera R. Bidirectional response of weak-axis end-plate moment connections: numerical approach. J Metals. 2020 Jul;10(7):964. 
  9. Song JA, Park HG, Lee CN, Eom TS. Earthquake resistance of prefabricated reinforced concrete beam-column connection. J Archit Inst Korea Struct Constr. 2011 Oct;27(10):19-26. 
  10. Wang H, Barbagallo F, Pan P. Test of precast pre-stressed beam-to-column joint with damage-free reinforced concrete slab. J Eng Str. 2020 May;210:110368. 
  11. Wang H, Marino EM, Pan P, Liu H, Nie X. Experimental study of a novel precast prestressed reinforced concrete beam-to-column joint. J Eng Str. 2018 Feb;156:68-81.  https://doi.org/10.1016/j.engstruct.2017.11.011
  12. Zhang J, Li C, Rong X, Zhang X, Li Y. Experimental study on the seismic performance of steel-concrete beam-column connections for prefabricated concrete frames. J Building Eng. 2021 Nov;43:103236. 
  13. Zhang L, Li H, Wang W. Retrofit strategies against progressive collapse of steel gravity frames. J App Sci. 2020 Jul;10(13):4600. 
  14. Lee DJ, Lee JD, Oh TS, Kang TH. Seismic experiment of precast concrete exterior beam-column joint using bolt type connection and prestressing method. J Korea Concr Inst. 2014 Dec;26(2):125-133.  https://doi.org/10.4334/JKCI.2014.26.2.125
  15. Choi HK, Choi YC, Choi CS. Hysteretic behavior and seismic resistant capacity of precast concrete beam-to-column connections. J Earthq Eng Soc Korea. 2010 Aug;14(4):61-71.  https://doi.org/10.5000/EESK.2010.14.4.061
  16. Kim SH, Lee DH, Kim YK, Lee SW, Yeo UY, Park JE. Seismic performance evaluation of dry precast concrete beam-column connections with special moment frame details. J Earthq Eng Soc Korea. 2023 Sep;27(5):203-211.  https://doi.org/10.5000/EESK.2023.27.5.203
  17. Shin DH, Seo SY, Kim KS. Experiment on the hysteretic behavior of a hollw PC column-half PC beam exterior joint. J Korea Concr Inst. 2017 Oct;29(5):515-524.  https://doi.org/10.4334/JKCI.2017.29.5.515
  18. Jang BS, Kim JH, Choi SH, Kim KS, Hwang JH, Choi SD. Structural behavior of precast wide girder-column joints under lateral cyclic loading. J Korea Concr Inst. 2021 Jun;33(3):289-297.  https://doi.org/10.4334/JKCI.2021.33.3.289
  19. Hwang JH, Choi SH, Kim JH, Kim KS, Woo WT. Reversed cyclic behavior of post-tensioned precast concrete beam-column connections with unbonded tendons. J Korea Concr Inst. 2018 Dec;30(6):657-664.  https://doi.org/10.4334/JKCI.2018.30.6.657
  20. Kim OJ, Oh JK, Kang SM. Development and seismic performance of vertical joints in precast concrete shear walls under cyclic loads. J. Korea Inst Str Maint Inspet. 2012 Dec;16(1):140-148.  https://doi.org/10.11112/jksmi.2012.16.1.140
  21. Choi YC, Lim JH, Kwon KH, Moon JH, Lee LH, Kim DJ. Inelastic behavior of exterior wide beam-column connections with U-shaped precast shell beam stressed by post-tensioning. J Archit Inst Korea Str Const. 2004 Dec;20(12):27-36. 
  22. Ha SS, Kim SH, Moon JH, Lee LH. An experimental study on the structural behavior of the half PC beam and column interior joint with strand. J Archit Inst Korea Str Const. 2007 Sep;23(9):3-11. 
  23. Choi YC, Lim JH, Moon JH, Lee LH, Kwon KH. Inelastic behavior of interior wide beam-column connections with U-shaped precast shell beam stressed by post-tensioning. J Archit Inst Korea Str Const. 2005 Jan;21(1):11-19.  https://doi.org/10.1680/macr.2006.61590
  24. Kim SH, Ryu GC, Ha SS, Moon JH, Lee LH. An experimental study of the structural behavior on the precast concrete exterior beam-column joint with through-bar type connection. J Archit Inst Korea Str Const. 2006 Nov;22(11):3-10. 
  25. Kim SH, Moon JH, Lee LH, An experimental study of the structural behavior on the precast concrete beam-column interior joint with splice type reinforcing bars. J Archit Inst Korea Str Const. 2004 Oct;20(10):53-61. 
  26. Lee WJ, Kim MS, Lee DH, Ju HJ, Kim KH. Seismic performance evaluation of intermediate precast structural walls. J Next Con Tec Ass. 2022 Jun;6(3):421-432.  https://doi.org/10.33097/JNCTA.2022.06.03.421
  27. KDS 41 17 00. Building seismic design code. Korea Construction Standards Center; c2022. 
  28. KDS 14 20 00. Concrete structural design code. Korea Construction Standards Center; c2022. 
  29. Huang W, Hu G, Miao X, Fan Z. Seismic performance analysis of a novel demountable precast concrete beam-column connection with multi-slit devices. J Building Eng. 2021 Dec;44:523. 
  30. Kim SH, Cho J , Oh HK, Choi SD, Yeo UY, Lee DH. Seismic performance evaluation of dry precast concrete beam-column connections with intermediate moment frame details. J Earthq Eng Soc Korea. 2023 May;27(3):129-137.  https://doi.org/10.5000/EESK.2023.27.3.129
  31. ANSYS v.19.1. Swanson analysis system; c2020.