Abstract

For successful waterproofing construction, it is very important to secure construction quality as well as material performance of waterproofing materials used in construction. Due to the long-term cost reduction policy following the economic downturn in the construction market, most construction companies are using general low-priced waterproof materials rather than high-quality waterproof materials without clear quality control standards. Without clear education on construction, construction is being carried out with meaning only on construction activities. In addition, the waterproofing method applied in combination is a situation where water leakage occurs due to waterproofing failure due to insufficient construction quality because the construction method is complicated. Therefore, it is necessary to review the quality control measures(design, materials, construction) for successful waterproofing work and improve problems that are derived so that stable waterproofing work can be done. In order to expect the leakage prevention effect of a building, first, it is required to select appropriate materials for each part of the building and environment in the design stage, and the selected materials must satisfy all items of the Korean Industrial Standard(KS). Second, to secure the quality of waterproofing construction, sincere construction by workers is required. In this paper, we tried to describe "review of waterproof design", "constructor education", "site inspection", and "criticism(correction/supplementation)" as quality control measures after material selection.

성공적인 방수 시공을 위해서는 건축에 사용되는 방수재료의 재질적 성능뿐만 아니라 시공 품질을 확보하는 것이 매우 중요하다. 건설경기 침체에 따른 장기적인 원가절감 정책으로 인해 대부분의 건설사에서는 명확한 품질관리 기준이 없는 고급 방수 자재보다는 일반 저가의 방수 자재를 사용하고 있으며, 건설에 대한 명확한 교육 없이 건설 활동에만 의미를 두고 건설을 진행하고 있다. 또한, 복합적으로 적용되는 방수공법은 시공공법이 복잡하여 시공 품질이 부족하고 방수 불량으로 누수가 발생하는 상황에 놓여있으며, 성공적인 방수공사를 위해서는 품질관리 방안(설계, 자재, 시공)을 검토하고, 파생되는 문제점을 개선하여 안정적인 방수공사가 이루어질 수 있도록 하는 것이 필요하다. 건축물의 누수방지 효과를 기대하기 위해서는 먼저 설계단계에서 건축물의 각 부분과 환경에 적합한 자재를 선정하여야 하며, 선정된 자재는 한국산업규격(KS)의 모든 항목을 만족하여야 한다. 둘째, 방수시고의 품질을 확보하기 위해서는 작업자의 성실한 시공이 요구된다. 본 논문에서는 자재 선정 후 품질관리 대책으로 "방수 설계 검토", "시공자 교육", "현장실사", "비평(수정/보완)"에관한 현장점검 체크리스트를 제시하여 현장에서 안전 및 고품질의 방수공사확보를 위한 개선방안을 제시하였습니다.

Keywords

Acknowledgement

This study was financially supported by the Seoul National University of Science & Technology.

References

  1. Kim SY, Lee JH, Song JY, Kim BI, Oh SK. Evaluation of chemical resistance performance of synthetic rubber and cement based injection repair materials used in underground concrete structures. Journal of the Korea Institute for Structural Maintenance and Inspection. 2017 Sep;21(5):148-55. https://doi.org/10.11112/jksmi.2017.21.5.148
  2. Song JY, Oh KH, Kim BI. Oh SK. Performance evaluation of waterproofing membrane systems subject to the concrete joint load behavior of below-grade concrete structures. Applied Sciences. 2017 Nov;7(11):1147. https://doi.org/10.3390/app7111147
  3. Kim SY, Yoo JY, Oh SK. A study on the performance evaluation of water(wash out) resistance of 5-type repair materials in water leakage of underground concrete structures. Journal of Korea Institute for Structural Maintenance and Inspection. 2020 Sep;24(5):61-8.
  4. Kim MJ, Lee SW, Kim SY, Oh SK. Constructional verification evaluation for securing the field quality of composite membrane waterproofing material. Proceedings of the Korea Institute of Building Construction. 2021 May 19-21; Jeju, Korea. Seoul (Korea): the Korea Institute of Building Construction; 2021. p. 87-9.
  5. Park JS, Kim DB, Park WG., Kim BI, Oh SK. Development of oil leakage stability evaluation for composite waterproofing methods using asphalt mastic and modified asphalt sheet in concrete structure. Journal of Korea Institute of Building Construction. 2019 Feb;19(1):19-29. https://doi.org/10.5345/JKIBC.2019.19.1.019
  6. Lee JH, Song JY, Oh SK. Leakage situation and main leakage areas of domesti residential building underground parking lots. Journal of the Korean Recycled Construction Resources Institute. 2019 Dec;4(4):496-503. https://doi.org/10.14190/JRCR. 2016.4.4.496
  7. Gawk KS, Ma SJ, Choi SM, Oh SK. Property analysis of waterproofing and corrosion-resistant performance in concrete water supply facilities. Journal of the Korea Recycled Construction Resources Institute. 2015;3(2):112-31.
  8. Han YJ, Oh KH, Kim SR, Kim BI, Oh SK. Consumer awareness analysis of residential building underground structure leakage prevention measurements. Journal of the Korean Recycled Construction Resources Institute. 2016 Dec;4(4):379-87. https://doi.org/10.14190/JRCR.2016.4.4.379
  9. Lee JH, Choi EK, Song JY, Kim SR, Oh SK. Applicability of composite polyurea method considering the required performance in underground parking lot upper slab. Journal of the Korean Recycled Construction Resources Institute. 2019 Sep;7(3):243-54. https://doi.org/10.14190/JRCR.2019.7.3.243
  10. KS F 3211. Waterproofing membrane coating for construction. Seoul (Korea): Korean Agency for Technology and Standards; 2021. 1-17 p.
  11. KS F 4917. Polymer-modified bitumen waterproofing sheet. Seoul (Korea): Korean Agency for Technology and Standards; 2022. 1-14 p.
  12. KS F 4934. Self-adhesive rubberized asphalt sheet. Seoul (Korea): Korean Agency for Technology and Standards; 2017. 1-13 p.