Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine) ;
  • Kyung Hwan Kim (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine) ;
  • Suk Ho Sohn (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine) ;
  • Yoonjin Kang (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine) ;
  • Ji Seong Kim (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine) ;
  • Jae Woong Choi (Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul National University College of Medicine)
  • 투고 : 2023.06.02
  • 심사 : 2023.08.21
  • 발행 : 2023.11.05

초록

Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

키워드

참고문헌

  1. Laufer G, Haverich A, Andreas M, et al. Long-term outcomes of a rapid deployment aortic valve: data up to 5 years. Eur J Cardiothorac Surg 2017;52:281-7. https://doi.org/10.1093/ejcts/ezx103
  2. Barnhart GR, Accola KD, Grossi EA, et al. TRANSFORM (Multicenter Experience with Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: performance of a rapid deployment aortic valve. J Thorac Cardiovasc Surg 2017;153:241-51. https://doi.org/10.1016/j.jtcvs.2016.09.062
  3. Borger MA, Moustafine V, Conradi L, et al. A randomized multicenter trial of minimally invasive rapid deployment versus conventional full sternotomy aortic valve replacement. Ann Thorac Surg 2015;99:17-25. https://doi.org/10.1016/j.athoracsur.2014.09.022
  4. Ferrari E, Roduit C, Salamin P, et al. Rapid-deployment aortic valve replacement versus standard bioprosthesis implantation. J Card Surg 2017;32:322-7. https://doi.org/10.1111/jocs.13139
  5. Rahmanian PB, Kaya S, Eghbalzadeh K, Menghesha H, Madershahian N, Wahlers T. Rapid deployment aortic valve replacement: excellent results and increased effective orifice areas. Ann Thorac Surg 2018;105:24-30. https://doi.org/10.1016/j.athoracsur.2017.07.047
  6. King M, Stambulic T, Payne D, Fernandez AL, El-Diasty M. The use of sutureless and rapid-deployment aortic valve prosthesis in patients with bicuspid aortic valve: a focused review. J Card Surg 2022;37:3355-62. https://doi.org/10.1111/jocs.16795
  7. Glauber M, Ferrarini M, Lio A, Miceli A. Dealing with a stenotic bicuspid aortic valve: is this still an off-label procedure for a sutureless valve? J Thorac Cardiovasc Surg 2015;150:858-9. https://doi.org/10.1016/j.jtcvs.2015.07.049
  8. Nguyen A, Fortin W, Mazine A, et al. Sutureless aortic valve replacement in patients who have bicuspid aortic valve. J Thorac Cardiovasc Surg 2015;150:851-7. https://doi.org/10.1016/j.jtcvs.2015.05.071
  9. Chiariello GA, Villa E, Messina A, Troise G. Dislocation of a sutureless prosthesis after type I bicuspid aortic valve replacement. J Thorac Cardiovasc Surg 2018;156:e87-9. https://doi.org/10.1016/j.jtcvs.2018.02.002
  10. Yun T, Kim KH, Sohn SH, Kang Y, Kim JS, Choi JW. Rapid-deployment aortic valve replacement in a real-world all-comers population. Thorac Cardiovasc Surg 2022 Oct 10 [Epub]. https://doi.org/10.1055/s-0042-1757241
  11. Sievers HH, Schmidtke C. A classification system for the bicuspid aortic valve from 304 surgical specimens. J Thorac Cardiovasc Surg 2007;133:1226-33. https://doi.org/10.1016/j.jtcvs.2007.01.039
  12. Sohn SH, Kim KH, Kang Y, Kim JS, Choi JW. Recovery from conduction abnormalities after aortic valve replacement using edwards intuity. Ann Thorac Surg 2021;112:1356-62. https://doi.org/10.1016/j.athoracsur.2021.04.036
  13. VARC-3 Writing Committee; Genereux P, Piazza N, et al. Valve Academic Research Consortium 3: updated endpoint definitions for aortic valve clinical research. J Am Coll Cardiol 2021;77:2717-46. https://doi.org/10.1016/j.jacc.2021.02.038
  14. Lancellotti P, Pibarot P, Chambers J, et al. Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 2016;17:589-90. https://doi.org/10.1093/ehjci/jew025
  15. Miceli A, Berretta P, Fiore A, et al. Sutureless and rapid deployment implantation in bicuspid aortic valve: results from the sutureless and rapid-deployment aortic valve replacement international registry. Ann Cardiothorac Surg 2020;9:298-304. https://doi.org/10.21037/acs-2020-surd-33
  16. Di Eusanio M, Phan K, Berretta P, et al. Sutureless and Rapid-Deployment Aortic Valve Replacement International Registry (SURDIR): early results from 3343 patients. Eur J Cardiothorac Surg 2018;54:768-73. https://doi.org/10.1093/ejcts/ezy132
  17. Borger MA, Dohmen PM, Knosalla C, et al. Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trial. Eur J Cardiothorac Surg 2016;50:713-20. https://doi.org/10.1093/ejcts/ezw042
  18. Kocher AA, Laufer G, Haverich A, et al. One-year outcomes of the Surgical Treatment of Aortic Stenosis with a Next Generation Surgical Aortic Valve (TRITON) trial: a prospective multicenter study of rapid-deployment aortic valve replacement with the EDWARDS INTUITY Valve System. J Thorac Cardiovasc Surg 2013;145:110-6. https://doi.org/10.1016/j.jtcvs.2012.07.108
  19. Coti I, Werner P, Kaider A, et al. Rapid-deployment aortic valve replacement for patients with bicuspid aortic valve: a single-centre experience. Eur J Cardiothorac Surg 2022;62:ezac017. https://doi.org/10.1093/ejcts/ezac017
  20. Michelena HI, Prakash SK, Della Corte A, et al. Bicuspid aortic valve: identifying knowledge gaps and rising to the challenge from the International Bicuspid Aortic Valve Consortium (BAVCon). Circulation 2014;129:2691-704. https://doi.org/10.1161/CIRCULATIONAHA.113.007851