DOI QR코드

DOI QR Code

Predictive Maintenance Plan based on Vibration Monitoring of Nuclear Power Plants using Industry 4.0

4차 산업기술을 활용한 원전설비 진동감시기반 예측정비 방안

  • 고도영 (한국수력원자력(주) 중앙연구원)
  • Received : 2023.05.02
  • Accepted : 2023.06.02
  • Published : 2023.06.30

Abstract

Only about 10% of selected equipment in nuclear power plants are monitored by wiring to address failures or problems caused by vibration. The purpose is primarily for preventive maintenance, not for predictive maintenance. This paper shows that vibration monitoring and diagnosis using Industrial 4.0 enables the complete predictive maintenance for all vibrating equipments in nuclear power plants with the convergence of internet of things; wireless technology, big data through periodic collection and artificial intelligence. Predictive maintenance using wireless technology is possible in all areas of nuclear power plants and in all systems, but it should satisfy regulatory guides on electromagnetic interference and cyber security.

Keywords

Acknowledgement

본 연구는 한국수력원자력(KHNP)의 중장기 연구개발 과제로 한국수력원자력 중앙연구원에서 수행되었다.

References

  1. Ko, D. Y., and Lee, S. I., 2013, "Applicable approach of the wireless technology for Korean nuclear power plants," Nuclear Engineering and Design, Vol. 265, pp. 519-525. doi:https://doi.org/10.1016/j.nucengdes.2013.09.001
  2. Reg. Guide 1.180 Rev.1, 2003, "Guideline for Evaluating Electromagnetic and Radio-Frequency Interference in Safety-Related instrumentation and Control Systems," U.S. Nuclear Regulatory Commission, Washington, DC.
  3. KINS/RS-N03.00 Rev.4, 2016, "Validation for EMC," Korea Institute of Nuclear Safety, Daejeon, Korea.
  4. KINS/RG-N03.09 Rev.2, 2015, "Validation on EMI in Safety-related Instrumentation and Control Systems," Korea Institute of Nuclear Safety, Daejeon, Korea.
  5. KINS/RS-N10.00 Rev.2, 2015, "Communication System," Korea Institute of Nuclear Safety, Daejeon, Korea.
  6. Reg. Guide 5.71 Rev.1, 2010, "Cyber Security Programs for Nuclear Facilities, Rev.1," U.S. Nuclear Regulatory Commission, Washington, DC.
  7. KINAC/RS-015 Rev.1, 2016, "Security of Computer and Information System in Nuclear Facilities," Korea Institute of Nuclear Nonproliferation and Control, Daejeon, Korea.
  8. KINAC/RS-019 Rev.0, 2015, "Identification of Critical Digital Assest in Nuclear Facilities," Korea Institute of Nuclear Nonproliferation and Control, Daejeon, Korea.
  9. EPRI, 2009, "Implementation Guideline for Wireless Networks and Wireless Equipment Condition Monitoring," Electric Power Research Institute, Palo Alto, California, USA, Final Report 1019186.
  10. KHNP, 2017, "Feasibility on Wireless Technology for Process Monitoring in Nuclear Power Plants," Korea Hydro & Nuclear Power Co., Ltd., Daejeon, Korea, 2017-50003339-Jeon-0781TM.