References
- Allen, R., Box, M., Liu, L. J. S., Larson, T. V., 2001, A Cost-effective weighing chamber for particulate matter filters, J. Air Waste Manag. Asso., 51(12), 1650-1653. https://doi.org/10.1080/10473289.2001.10464392
- Brown, A. S., Yardley, R. E., Quincey, P. G., Butterfield, D. M., 2006, Studies of the sffect of humidity and other factors on some different filter materials used for gravimetric measurements of ambient particulate matter, Atmos. Env., 40, 4670-4678. https://doi.org/10.1016/j.atmosenv.2006.04.028
- Carlton, A. G., Teitz, A., 2002, Design of a cost-effective weighing facility for PM2.5 quality assurance, Journal of the Air & Waste Management Association, 52(5), 506-510. https://doi.org/10.1080/10473289.2002.10470802
- Charell, P. R.. Hawley, R. E., 1981, Characteristics of water adsorption on air aampling ailters, American Indus. Hygiene Assoc. J.. 42, 353-360. https://doi.org/10.1080/15298668191419875
- Kuo, Y. M., Hsu, C. W., Chen, J. Y., Huang, S. H., Lee, L. H., Chen, C. C., 2015, Development of a reliable and cost-effective weighing chamber for aerosol sample analyse s, Aerosol and Air Quality Research, 15, 749-758. https://doi.org/10.4209/aaqr.2014.10.0260
- Lawless, P. A., Rodes, C. E., 1999, Maximizing data quality in the gravimetric analysis of personal exposure sample filters, J Air Waste Manag. Assoc.. 49, 1039-1049. https://doi.org/10.1080/10473289.1999.10463877
- Marsh, K. N., 1987, Recommended reference materials for the realization of physiochemical properties, Ch. 2, Ed.; Blackwell Scientific Publications, Oxford UK, 270.
- Ministry of Environment (MOE), 2022, Air pollution process test standards, fine Particulate Matter(PM2.5) in ambinet air - gravimetric measurement method, National Institute of Environmental Science, ES 01606.1.
- Tierney, G.P., Conner, W. D., 1967, Hygroscopic effects on weight derterminations of particulates collected on glass-fiber filters, American Indus. Hygiene Assoc. J.. 28. 363-365. https://doi.org/10.1080/00028896709342537
- Tsai, C. J., Chang, C. T., Shih, B. H., Aggarwal, S. G., Li, S. N., Chein, H. M., Shih, T. S., 2002, The effect of environmental conditions and electrical charge on the weighing accuracy of different filter materials, Sci. Total Environ.. 293, 201-206. https://doi.org/10.1016/S0048-9697(02)00015-3
- U.S. Environmental Protection Agency (US EPA), 2016, Quality assurance guidance document 2.12: Monitoring PM2.5 in ambient air using designated reference or class I equivalent methods, http://www.epa.gov.