References
- Ahnesjo A, Aspradakis MM. Dose calculations for external photon beams in radiotherap. Phys. Med. Biol. 1999;44(11):R99-155. https://doi.org/10.1088/0031-9155/44/11/201
- Verhaegen F, Seuntjens J. Monte Carlo modelling of external radiotherapy photon beams. Phys. Med. Biol. 2003;48(21):R107-64. https://doi.org/10.1088/0031-9155/48/21/R01
- Chauvie S, Scielzo G. Radiotherapy treatment planning with Monte Carlo on a distributed system. IEEE. 2004;1765-9.
- Gonias P, Zaverdinos P, Alkhorayef M, Sulieman A, Kappas C, Theodorou K. Monte Carlo Simulation of 6MV Varian Clinac Photon Beam Using GEANT4-GATE. J At Nucl Phys. 2020;2(1):30-8.
- An JS, Lee CL, Baek CH. Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6. Journal of Radiological Science and Technology. 2016;39(4):571-5. https://doi.org/10.17946/JRST.2016.39.4.12
- Agostinelli S, Allison J, Amako K, Apostolakis J, Araujo H, Arce P, et al. Geant4-a simulation toolkit. Nuclear Instruments and Methods in Physics Research A. 2003;506(3):250-303. https://doi.org/10.1016/S0168-9002(03)01368-8
- Sheikh-Bagheri D, Rogers DWO. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med. Phys. 2002;29(3):391-402. https://doi.org/10.1118/1.1445413
- Ivanchenko V, Apostolakis J, Bagulya A, Abdelouahed HB, Black R, Bogdanov A, et al. Recent Improvements in Geant4 Electromagnetic Physics Models and Interfaces. Progress in Nuclear Science and Technology. 2011;2:898-903. https://doi.org/10.15669/pnst.2.898
- Pandola L, Andenna C, Caccia B. Validation of the GEANT4 simulation of bremsstrahlung from thick targets below 3 MeV. Nuclear Instruments and Methods in Physics Research B. 2015;41-8.
- Kang SK, Ahn SH, Kim CY. A Study on Photon Dose Calculation in 6 MV Linear Accelerator Based on Monte Carlo Method. Journal of Radiological Science and Technology. 2011;34(1):43-50.
- International Atomic Energy Agency. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry Based on Standards of Absorbed Dose to Water. Technical Reports Series No. 398; 2000.
- International Atomic Energy Agency. Commissioning and quality assurance of computerized planning systems for radiation treatment of cancer. Technical Reports Series No.430; 2004.
- Venselaar J, Welleweerd H, Mijnheer B. Tolerances for the accuracy of photon beam dose calculations of treatment planning systems. Radiotherapy and Oncology 60. 2001;191-201. https://doi.org/10.1016/S0167-8140(01)00377-2
- Mesbahi A, Fix M, Allahverdi M, Grein E, Garaati H. Monte Carlo calculation of Varian 2300C/D Linac photon beam characteristics: A comparison between MCNP4C, GEANT3 and measurements. Applied Radiation and Isotopes 62. 2005;469-77. https://doi.org/10.1016/j.apradiso.2004.07.008
- Baumgartner A, Steurer A, Maringer FJ. Simulation of photon energy spectra from Varian 2100C and 2300C/D Linacs: Simplified estimates with PENELOPE Monte Carlo models. Applied Radiation and Isotopes 67. 2009;2007-12. https://doi.org/10.1016/j.apradiso.2009.07.010
- Chetty IJ, Curran B, Cygler JE, DeMarco JJ, Ezzell G, Faddegon BA, et al. Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med. Phys. 2007;34(12):4818-36. https://doi.org/10.1118/1.2795842
- Keall PJ, Siebers JV, Arnfield M, Kim JO, Mohan R. Monte Carlo dose calculations for dynamic IMRT treatments. Phys. Med. Biol. 2001;46.
- Ding GX. Using Monte Carlo simulations to commission photon beam output factors-A feasibility study. Physics in Medicine & Biology. 2003;48(23): 3865-74. https://doi.org/10.1088/0031-9155/48/23/005
- Mesbahi A, Reilly AJ, Thwaites DI. Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator. Applied Radiation and Isotopes. 2006;64(6):656-62. https://doi.org/10.1016/j.apradiso.2005.12.012
- Fix MK, Keller H, RRegsegger P, Born EJ. Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy. Med Phys. 2000; 27(12):2739-47. https://doi.org/10.1118/1.1318220
- Sardari D, Maleki R, Samavat H, Esmaeeli A. Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code. Reports of Practical Oncology and Radiotherapy. 2010;64-8.
- Ding GX. Dose discrepancies between Monte Carlo calculations and measurements in the buildup region for a high-energy photon beam. Med. Phys. 2002;29(11):2459-63. https://doi.org/10.1118/1.1514237
- Andreo P. Monte Carlo techniques in medical radiation physics. Physics in Medicine & Biology. 1991;36(7):861-920. https://doi.org/10.1088/0031-9155/36/7/001
- Bakkali JEL, Bardouni TEL. Validation of Monte Carlo Geant4 code for a 6 MV Varian linac. Journal of King Saud University-Science. 2017;29:106-13. https://doi.org/10.1016/j.jksus.2016.03.003
- JimRnez Spang F. Monte Carlo Study of the Dosimetry of Small-Photon Beams Using CMOS Active Pixel Sensors [dissertation]. University College London; 2011.
- Tzedakis A, Damilakis JE, Mazonakis M, Stratakis J, Varveris H, Gourtsoyiannis N. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams. Med. Phys. 2004;31(4): 907-13. https://doi.org/10.1118/1.1668551
- Cho SH, Vassiliev ON, Lee SS, Liu HH, Ibbott GS, Mohan R. Reference photon dosimetry data and reference phase space data for the 6 MV photon beam from Varian Clinac 2100 series linear accelerators. Med. Phys. 2005;32(1):137-48. https://doi.org/10.1118/1.1829172