DOI QR코드

DOI QR Code

Axial compression behavior of double-skinned composite tubular columns under pure compression on concrete cores

  • Lee, Jeonghwa (Futhre and Fusion Lab of Architectural Civil and Environmental Engineering, Korea University) ;
  • Byun, Namju (Futhre and Fusion Lab of Architectural Civil and Environmental Engineering, Korea University) ;
  • Kang, Young Jong (School of Civil, Environmental and Architectural Engineering, Korea University) ;
  • Won, Deok Hee (Department of Civil Engineering, Halla University) ;
  • Kim, Seungjun (School of Civil, Environmental and Architectural Engineering, Korea University)
  • Received : 2021.12.30
  • Accepted : 2022.04.18
  • Published : 2022.05.25

Abstract

A double-skinned composite tubular (DSCT) column, which is an internally confined concrete-filled tubular column with a hollow section, has been developed for efficient use of materials that reduce self-weight and enhance seismic performance. It exhibits excellent material behavior with ductility owing to the confinement induced by outer and inner steel tubes. This study conducted axial compression tests considering the effects of steel tube thickness and hollow diameter ratios of DSCT columns on the material behavior of confined concrete under pure axial compression on concrete cores. From the axial compression tests, various combinations of outer and inner tube thicknesses and two different hollow section ratios were considered. Additionally, confined concrete material behavior, axial strength, failure modes, and ductility of DSCT columns were evaluated. Based on this study, it was concluded that the tests show a good correlation with peak strength and shapes of nonlinear stress-strain curves presented in literature; however, the thinner outer and inner steel tubes may reduce the ductility of DSCT columns when using thinner outer and inner tubes and higher confined stress levels. Finally, the minimum thickness requirements of the steel tubes for DSCT columns were discussed in terms of strength and ductility of test specimens.

Keywords

Acknowledgement

This research was supported by a grant (PA110020) from the Patented Formula Commercialization Program funded by the Seoul Business Agency. It was also funded by the Korea National Research Foundation (grant number NRF-2018R1D1A1B07050335 and NRF-2021R1A5A1032433)

References

  1. ANSI/AISC (2016), ANSI/AISC 360-16 Specification for Structural Steel Buildings, American Istitute of Steel Construction, USA.
  2. Han, T.H., Han, K.H., Han, S.Y., Kim, S.N., Kang, J.O. and Kang, Y.J. (2005). "The behavior of an internally confined hollow concrete filled steel tube column", Proceeding of the 8th KoreaJapan joint semina.
  3. Han, T.H., Kim, S., Won, D.H. and Kang, Y.J. (2013), "Performance of a double-skinned composite tubular column under lateral loading: Analysis", Mag. Concrete Res., 65(2), 121-135. https://doi.org/10.1680/macr.12.00024.
  4. Han, T.H., Stallings, J.M. and Kang, Y.J. (2010), "Nonlinear concrete model for double-skinned composite tubular columns", Construct. Build. Mater., 24 2542-2553. https://doi.org/10.1016/j.conbuildmat.2010.06.001.
  5. Hu, H.T. and Su, F.C. (2011), "Nonlinear analysis of short concrete-filled double skin tube columns subjeced to axial compressive forces", Marine Struct., 24(4), 319-337. https://doi.org/10.1016/j.marstruc.2011.05.001.
  6. KCI (2012), Korean Concrete Structure Standard, Ministry of Land, Transport and Maritime Affairs
  7. Kerr, A.D. and Soifer, M.T. (1996), "The linearization of the prebuckling state and its effects on the determined instability load", J. Appl. Mech.. 36(4), 775-785. https://doi.org/10.1115/1.3564770.
  8. Liang, Q.Q. (2016), "Nonlinear analysis of circular double-skin concrete-flled steel tubular columns under axial compression", Eng. Struct., 131 639-650. https://doi.org/10.1016/j.engstruct.2016.10.019.
  9. Liang, Q.Q. (2018), "Numerical simulation of high strength circular double-skin concrete-filled steel tubular slender columns", Eng. Struct., 168, 205-217. https://doi.org/10.1016/j.engstruct.2018.04.062.
  10. Mander, J.B., Priestley, M.J.N. and Park, R. (1988), "heoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804).
  11. Pagoulatou, M., Sheehan, T., Dai, X.H. and Lam, D. (2014), "Finite element analysis on the capacity of circular concretefilled double-skin steel tubular (CFDST) stub colums", Eng. Struct., 72, 102-112. https://doi.org/10.1016/j.engstruct.2014.04.039.
  12. Popovics, S. (1973), "A numerical approach to the complete stress-strain curves of concrete", Cement Concrete Res., 3(5), 583-599. https://doi.org/10.1016/0008-8846(73)90096-3.
  13. Shakir-Khalil, H. and Illoul, S. (1987), "Composite columns of concentric steel tubes", Proceeding of Conference on the Design and Construction of Non Conventional Structures.
  14. Tao, Z., Han, L.H. and Zhao, X.L. (2004), "Behavior of concretefilled double skn (CHS inner and CHS outer) steel tubular stub columns and beam columns", J. Construct. Steel Res., 60 1129-1158. https://doi.org/10.1016/j.jcsr.2003.11.008.
  15. Wei, S., Mau, M.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: experiment", J. Struct. Eng., 121(12), 1806-1814. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1806).
  16. Wei, S., Mau, S.T., Vipulanandan, C. and Mantrala, S.K. (1995), "Performance of new sandwich tube under axial loading: Analysis", J. Struct. Eng., 121(12), 1815-1821. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:12(1815).
  17. Won, D.H., Han, T.H., Kim, S., Lee, J.H. and Kang, Y.J. (2014), "Confining effect of concrete in double-skinned composite tubular columns", Computers Concrete. 14(5), 613-633. https://doi.org/10.12989/cac.2014.14.5.613.
  18. Zhao, X.L. and Grzebieta, R. (2002), "Strength and ductility of concrete filled double skin (SHS inner and SHS outer) tubes", Thin-Wall. Struct., 40 199-213. https://doi.org/10.1016/S0263-8231(01)00060-X.