Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses

  • Yang, Min-Seong (Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University) ;
  • Kim, Seong-Kyun (Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University) ;
  • Heo, Seong-Joo (Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University) ;
  • Koak, Jai-Young (Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University) ;
  • Park, Ji-Man (Department of Prosthodontics & Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University)
  • Received : 2022.04.21
  • Accepted : 2022.08.22
  • Published : 2022.08.31

Abstract

PURPOSE. The purpose of this study was to analyze the marginal fit of three-unit resin prostheses printed with the stereolithography (SLA) method in two build orientations (45°, 60°) and two layer thicknesses (50 ㎛, 100 ㎛). MATERIALS AND METHODS. A master model for a three-unit resin prosthesis was designed with two implant abutments. Forty specimens were printed using an SLA 3D printer. The specimens were printed with two build orientations (45°, 60°), and each orientation was printed with two layer thicknesses (50 ㎛, 100 ㎛). The marginal fit was measured as the marginal gap (MG) and absolute marginal discrepancy (AMD), and MG and AMD measurements were performed at 8 points per abutment, for 16 points per specimen. All statistical analyses were performed using SPSS software. Two-way analysis of variance (ANOVA) was separately performed on the MG and AMD values of the build orientations and layer thicknesses. Moreover, one-way ANOVA was performed for each point within each group. RESULTS. The margins of the area adjacent to the pontic showed significantly high values, and the values were smaller when the build orientation was 45° than when it was 60°. However, the margin did not differ significantly according to the layer thicknesses. CONCLUSION. The marginal fit of the three-unit resin prosthesis fabricated by the SLA 3D method was affected by the pontic. Moreover, the marginal fit was affected by the build orientation. The 45° build orientation is recommended.

Keywords

Acknowledgement

This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2018R1D1A1B07042333) and by the Korea Medical Device Development Fund grant funded by the Korea government (the Ministry of Science and ICT, the Ministry of Trade, Industry and Energy, the Ministry of Health & Welfare, Republic of Korea, the Ministry of Food and Drug Safety) (Project Number: 202011A02). The authors declared no conflicts of interests.

References

  1. Boitelle P, Mawussi B, Tapie L, Fromentin O. A system-atic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 2014;41:853-74. https://doi.org/10.1111/joor.12205
  2. Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014;2014:783948.
  3. Leeson D. The digital factory in both the modern dental lab and clinic. Dent Mater 2020;36:43-52. https://doi.org/10.1016/j.dental.2019.10.010
  4. Torabi K, Farjood E, Hamedani S. Rapid prototyping technologies and their applications in prosthodontics, a review of literature. J Dent (Shiraz) 2015;16:1-9.
  5. van Noort R. The future of dental devices is digital. Dent Mater 2012;28:3-12. https://doi.org/10.1016/j.dental.2011.10.014
  6. Alharbi N, Wismeijer D, Osman RB. Additive manufacturing techniques in prosthodontics: where do we currently stand? a critical review. Int J Prosthodont 2017;30:474-84. https://doi.org/10.11607/ijp.5079
  7. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11. https://doi.org/10.1038/sj.bdj.2008.350
  8. Nayar S, Bhuminathan S, Bhat WM. Rapid prototyping and stereolithography in dentistry. J Pharm Bioallied Sci 2015;7:S216-9.
  9. Della Bona A, Cantelli V, Britto VT, Collares KF, Stansbury JW. 3D printing restorative materials using a ste-reolithographic technique: a systematic review. Dent Mater 2021;37:336-50. https://doi.org/10.1016/j.dental.2020.11.030
  10. Byun HS, Lee KH. Determination of the optimal part orientation in layered manufacturing using a genetic algorithm. Int J Product Res 2005;43:2709-24. https://doi.org/10.1080/00207540500031857
  11. Zwier MP, Wits WW. Design for additive manufacturing: automated build orientation selection and optimization. Procedia Cirp 2016;55:128-33. https://doi.org/10.1016/j.procir.2016.08.040
  12. Singhal SK, Jain PK, Pandey PM. Adaptive slicing for SLS prototyping. Computer-Aided Des Appl 2008;5: 412-23. https://doi.org/10.3722/cadaps.2008.412-423
  13. Park GS, Kim SK, Heo SJ, Koak JY, Seo DG. Effects of printing parameters on the fit of implant-supported 3D printing resin prosthetics. Materials (Basel) 2019; 12:2533.
  14. Jang GJ, Kim SK. Fit analysis of the stereolithography-manufacturing three-unit resin prosthesis with various 3D-printing build orientations and layer thicknesses. PhD Thesis. Seoul National University Graduate School, 2021.
  15. Wu J, Xie H, Sadr A, Chung KH. Evaluation of internal fit and marginal adaptation of provisional crowns fabricated with three different techniques. Sensors (Basel) 2021;21:740. https://doi.org/10.3390/s21010054
  16. Peng CC, Chung KH, Yau HT, Ramos V Jr. Assessment of the internal fit and marginal integrity of interim crowns made by different manufacturing methods. J Prosthet Dent 2020;123:514-22. https://doi.org/10.1016/j.prosdent.2019.02.024
  17. Mai HN, Lee KB, Lee DH. Fit of interim crowns fabricated using photopolymer-jetting 3D printing. J Prosthet Dent 2017;118:208-15. https://doi.org/10.1016/j.prosdent.2016.10.030
  18. Lee WS, Lee DH, Lee KB. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont 2017;9:265-70. https://doi.org/10.4047/jap.2017.9.4.265
  19. Gonzalo E, Suarez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009;102:378-84. https://doi.org/10.1016/S0022-3913(09)60198-0
  20. Yeo IS, Yang JH, Lee JB. In vitro marginal fit of three all-ceramic crown systems. J Prosthet Dent 2003;90: 459-64. https://doi.org/10.1016/j.prosdent.2003.08.005
  21. Holmes JR, Sulik WD, Holland GA, Bayne SC. Marginal fit of castable ceramic crowns. J Prosthet Dent 1992; 67:594-9. https://doi.org/10.1016/0022-3913(92)90153-2
  22. Burns DR, Beck DA, Nelson SK; Committee on Re - search in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. J Prosthet Dent 2003;90:474-97. https://doi.org/10.1016/S0022-3913(03)00259-2
  23. Vojdani M, Torabi K, Farjood E, Khaledi A. Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD/CAM and conventional wax up techniques. J Dent (Shiraz) 2013;14: 118-29.
  24. American Dental Association. ANSI/ADA Specification No. 8 for zinc phosphate cement. Guide to dental materials and devices 1971;1970-1.
  25. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11. https://doi.org/10.1038/sj.bdj.4802708
  26. Neves FD, Prado CJ, Prudente MS, Carneiro TA, Zancope K, Davi LR, Mendonca G, Cooper LF, Soares CJ. Micro-computed tomography evaluation of marginal fit of lithium disilicate crowns fabricated by using chairside CAD/CAM systems or the heat-pressing technique. J Prosthet Dent 2014;112:1134-40. https://doi.org/10.1016/j.prosdent.2014.04.028
  27. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-8. https://doi.org/10.1016/0022-3913(89)90170-4
  28. Brand RW, Isselhard DE. Anatomy of Orofacial Structures-Enhanced 7th Edition-E-Book: A Comprehensive Approach. Elsevier Health Sciences, 2014.
  29. Goodacre CJ, Campagni WV, Aquilino SA. Tooth preparations for complete crowns: an art form based on scientific principles. J Prosthet Dent 2001;85:363-76. https://doi.org/10.1067/mpr.2001.114685
  30. Jang GJ, Kim SK, Heo SJ, Koak JY, Park JM. Investigation of optimal cement space in 3D printed 3-unit resin prosthesis: a pilot study. Implantology 2020;24:62-75. https://doi.org/10.32542/implantology.202007
  31. Unkovskiy A, Bui PHB, Schille C, Geis-Gerstorfer J, Huettig F, Spintzyk S. Objects build orientation, positioning, and curing influence dimensional accuracy and flexural properties of stereolithographically printed resin. Dent Mater 2018;34:e324-33. https://doi.org/10.1016/j.dental.2018.09.011
  32. Osman RB, Alharbi N, Wismeijer D. Build angle: does it influence the accuracy of 3D-printed dental restorations using digital light-processing technology? Int J Prosthodont 2017;30:182-8. https://doi.org/10.11607/ijp.5117
  33. Rakhshan, V. Marginal integrity of provisional resin restoration materials: A review of the literature. Saudi J Dent Res 2015;6:33-40. https://doi.org/10.1016/j.sjdr.2014.03.002
  34. Huang Q, Zhang J, Sabbaghi A, Dasgupta T. Optimal offline compensation of shape shrinkage for three-dimensional printing processes. IIE trans 2015;47:431-41. https://doi.org/10.1080/0740817X.2014.955599
  35. Fusayama, T. Factors and technique of precision casting part II. J Prosthet Dent 1959;9:486-97. https://doi.org/10.1016/0022-3913(59)90081-2
  36. Kelly JR, Rose TC. Nonprecious alloys for use in fixed prosthodontics: a literature review. J Prosthet Dent 1983;49:363-70. https://doi.org/10.1016/0022-3913(83)90279-2
  37. Danesh G, Lippold C, Mischke KL, Varzideh B, Reinhardt KJ, Dammaschke T, Schafer E. Polymerization characteristics of light- and auto-curing resins for individual splints. Dent Mater 2006;22:426-33. https://doi.org/10.1016/j.dental.2005.04.032
  38. Filho JD, Poskus LT, Guimaraes JG, Barcellos AA, Silva EM. Degree of conversion and plasticization of dimethacrylate-based polymeric matrices: influence of light-curing mode. J Oral Sci 2008;50:315-21. https://doi.org/10.2334/josnusd.50.315
  39. Tjan AH, Castelnuovo J, Shiotsu G. Marginal fidelity of crowns fabricated from six proprietary provisional materials. J Prosthet Dent 1997;77:482-5. https://doi.org/10.1016/S0022-3913(97)70140-9
  40. Yu BY, Son K, Lee KB. Evaluation of intaglio surface trueness and margin quality of interim crowns in accordance with the build angle of stereolithography apparatus 3-dimensional printing. J Prosthet Dent 2021;126:231-7. https://doi.org/10.1016/j.prosdent.2020.04.028
  41. Alharbi N, Osman RB, Wismeijer D. Factors influencing the dimensional accuracy of 3D-printed full-cover-age dental restorations using stereolithography technology. Int J Prosthodont 2016;29:503-10. https://doi.org/10.11607/ijp.4835
  42. Taufik M, Jain PK. Role of build orientation in layered manufacturing: a review. Int J Manuf Technol Manag 2013;27:47-73. https://doi.org/10.1504/IJMTM.2013.058637
  43. Favero CS, English JD, Cozad BE, Wirthlin JO, Short MM, Kasper FK. Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models. Am J Orthod Dentofacial Orthop 2017; 152:557-65. https://doi.org/10.1016/j.ajodo.2017.06.012
  44. Zhang ZC, Li PL, Chu FT, Shen G. Influence of the three-dimensional printing technique and printing layer thickness on model accuracy. J Orofac Orthop 2019;80:194-204. https://doi.org/10.1007/s00056-019-00180-y
  45. Nawafleh NA, Mack F, Evans J, Mackay J, Hatamleh MM. Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review. J Prosthodont 2013;22:419-28. https://doi.org/10.1111/jopr.12006
  46. Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent 1990;64: 18-24. https://doi.org/10.1016/0022-3913(90)90147-5
  47. May KB, Russell MM, Razzoog ME, Lang BR. Precision of fit: the Procera AllCeram crown. J Prosthet Dent 1998;80:394-404. https://doi.org/10.1016/S0022-3913(98)70002-2
  48. Mitchell CA, Pintado MR, Douglas WH. Nondestructive, in vitro quantification of crown margins. J Prosthet Dent 2001;85:575-84. https://doi.org/10.1067/mpr.2001.114268
  49. Wolfart S, Wegner SM, Al-Halabi A, Kern M. Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation. Int J Prosthodont 2003;16:587-92.
  50. Mously HA, Finkelman M, Zandparsa R, Hirayama H. Marginal and internal adaptation of ceramic crown restorations fabricated with CAD/CAM technology and the heat-press technique. J Prosthet Dent 2014;112: 249-56. https://doi.org/10.1016/j.prosdent.2014.03.017