Acknowledgement
This research was supported by the National Research Foundation of Korea (NRF) grant (No. 2020M2D9A309417021) and the Nuclear Safety Research Program through the Korea Foundation of Nuclear Safety (KoFONS) using the financial resource granted by the Nuclear Safety and Security Commission (NSSC) of the Republic of Korea (No.2003013&2205013).
References
- Alhazmi A, Gianoli C, Neppl S, Martins J, Veloza S, Podesta M, et al. A novel approach to EPID-based 3D volumetric dosimetry for IMRT and VMAT QA. Phys Med Biol. 2018;63:115002.
- Huh HD, Kim S. History of radiation therapy technology. Prog Med Phys. 2020;31:124-134. https://doi.org/10.14316/pmp.2020.31.3.124
- Farhood B, Ghorbani M, Abdi Goushbolagh N, Najafi M, Geraily G. Different methods of measuring neutron dose/ fluence generated during radiation therapy with megavoltage beams. Health Phys. 2020;118:65-74. https://doi.org/10.1097/HP.0000000000001130
- Israngkul-Na-Ayuthaya I, Suriyapee S, Pengvanich P. Evaluation of equivalent dose from neutrons and activation products from a 15-MV X-ray LINAC. J Radiat Res. 2015;56:919-926. https://doi.org/10.1093/jrr/rrv045
- Trang LTN, Chuong HD, Thanh TT. Optimization of p-type HPGe detector model using Monte Carlo simulation. J Radioanal Nucl Chem. 2021;327:287-297. https://doi.org/10.1007/s10967-020-07473-2
- Kaya S, Celik N, Bayram T. Effect of front, lateral and back dead layer thicknesses of a HPGe detector on full energy peak efficiency. Nucl Inst Methods Phys Res. 2022;1029:166401.
- Novotny SJ, To D. Characterization of a high-purity germanium (HPGe) detector through Monte Carlo simulation and nonlinear least squares estimation. J Radioanal Nucl Chem. 2015;304:751-761. https://doi.org/10.1007/s10967-014-3902-7
- Konstantinova M, Germanas D, Gudelis A, Plukis A. Efficiency calibration of high-purity germanium detector using Monte Carlo simulations including coincidence-summing corrections: volume source case. Lith J Phys. 2021;61:66-73.
- Subercaze A, Sauzedde T, Domergue C, Destouches C, Philibert H, Fausser C, et al. Effect of the geometrical parameters of an HPGe detector on efficiency calculations using Monte Carlo methods. Nucl Inst Methods Phys Res. 2022;1039:167096.
- Aviv O, Elia P. Monte-Carlo simulations of the full-energy-peak efficiency for a broad-energy germanium detector-a comparison between GEANT4 and FLUKA. J Inst. 2020;15:P05016.
- Andreotti E, Hult M, Marissens G, Lutter G, Garfagnini A, Hemmer S, et al. Determination of dead-layer variation in HPGe detectors. Appl Radiat Isot. 2014;87:331-335. https://doi.org/10.1016/j.apradiso.2013.11.046
- Bolukdemir MH, Uyar E, Aksoy G, unlu H, Dikmen H, Ozgur M. Investigation of shape effects and dead layer thicknesses of a coaxial HPGe crystal on detector efficiency by using PHITS Monte Carlo simulation. Radiat Phys Chem. 2021;189:109746.
- Liye L, Jizeng M, Franck D, Carlan LD, Binquan Z. Monte Carlo efficiency transfer method for full energy peak efficiency calibration of three type HPGe detectors: a coaxial N-type, a coaxial P-type and four BEGe detectors. Nucl Inst Methods Phys Res. 2006;564:608-613. https://doi.org/10.1016/j.nima.2006.03.013
- Boson J, Agren G, Johansson L. A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations. Nucl Inst Methods Phys Res. 2008;587:304-314. https://doi.org/10.1016/j.nima.2008.01.062
- Loan TTH, Ba VN, Thy THN, Hong HTY, Huy NQ. Determination of the dead-layer thickness for both p- and n-type HPGe detectors using the two-line method. J Radioanal Nucl Chem. 2018;315:95-101.
- Huy NQ. Dead-layer thickness effect for gamma spectra measured in an HPGe p-type detector. Nucl Inst Methods Phys Res. 2011;641:101-104. https://doi.org/10.1016/j.nima.2011.02.097
- Elanique A, Marzocchi O, Leone D, Hegenbart L, Breustedt B, Oufni L. Dead layer thickness characterization of an HPGe detector by measurements and Monte Carlo simulations. Appl Radiat Isotopes. 2012;70:538-542. https://doi.org/10.1016/j.apradiso.2011.11.014
- Kwon NH, Jang YJ, Kim J, Kim KB, Yoo J, Ahn SH, et al. Measurements of neutron activation and dose rate induced by high-energy medical linear accelerator. Prog Med Phys. 2021;32:145-152. https://doi.org/10.14316/pmp.2021.32.4.145