DOI QR코드

DOI QR Code

Critical heat flux in a CANDU end shield - Influence of shielding ball diameter

  • 투고 : 2021.05.24
  • 심사 : 2021.10.08
  • 발행 : 2022.04.25

초록

Experiments were performed to measure the critical heat flux (CHF) on a vertical surface abutting a coarse packed bed of spherical particles. This geometry is representative of a CANDU reactor calandria tubesheet facing the end shield cavity during the in-vessel retention (IVR) phase of a severe accident. Deionized light water was used as the working fluid. Low carbon steel shielding balls with diameters ranging from 6.4 to 12.7 mm were used, allowing for the development of an empirical correlation of CHF as a function of shielding ball diameter. Previously published data is used to develop a more comprehensive empirical correlation accounting for the impacts of both shielding ball diameter and heating surface height. Tests using borosilicate shielding balls demonstrated that the dependence of CHF on shielding ball thermal conductivity is insignificant. The deposition of iron oxide particles transported from shielding balls to the heating surface is verified to increase CHF non-trivially. The results presented in this paper improve the state of the knowledge base permitting quantitative prediction of CHF in the CANDU end shield, refining our ability to assess the feasibility of IVR. The findings clarify the mechanisms governing CHF in this scenario, permitting identification of potential future research directions.

키워드

과제정보

This work was supported by Canadian Nuclear Laboratories (CNL), and CNL's Federal Nuclear Science and Technology program. In addition, the author would like to thank the various CNL staff members who assisted with the experimental work, and the reviewers for their constructive comments and suggestions.

참고문헌

  1. J.C. Luxat, Thermal-hydraulic aspects of progression to severe accidents in CANDU reactors, Nucl. Technol. 167 (1) (2009) 187-210. https://doi.org/10.13182/nt09-a8862
  2. T. Nitheanandan, M.J. Brown, Backup and ultimate heat sinks in CANDU reactors for prolonged SBO accidents, Nucl. Eng. Technol. 45 (5) (2013) 589-596. https://doi.org/10.5516/NET.03.2013.711
  3. F. Zhou, D.R. Novog, Mechanistic modelling of station blackout accidents for a generic 900 MW CANDU plant using the modified RELAP/SCDAPSIM/MOD3.6 code, Nucl. Eng. Des. 335 (2018) 21-93.
  4. J. Spencer, Results of air barbotage experiments simulating two-phase flow in a CANDU end Shield during in-vessel retention, ASME J. Nucl. Rad. Sci. 3 (2) (2017) 1-10. https://doi.org/10.1115/1.4035566
  5. J. Spencer, Measurement of critical heat flux in a CANDU end shield consisting of a vertical surface abutting a packed bed of steel shielding balls, CNL Nucl. Rev. 6 (1) (2017) 79-90.
  6. C.Y. Wang, C. Beckermann, A two-phase mixture model of liquid-gas flow and heat transfer in porous media. Part II: application to pressure-driven flow adjacent to a vertical heated plate, Int. J. Heat Mass Tran. 36 (11) (1993) 2759-2768. https://doi.org/10.1016/0017-9310(93)90095-N
  7. C.Y. Wang, C. Beckermann, Boundary-layer analysis of buoyancy-driven two-phase flow in capillary porous media, J. Heat Tran. 117 (1995) 1082-1087. https://doi.org/10.1115/1.2836290
  8. V.X. Tung, V.K. Dhir, Experimental study of boiling heat transfer from a sphere embedded in a liquid-saturated porous medium, J. Heat Tran. 112 (1990) 736-743. https://doi.org/10.1115/1.2910448
  9. S.S. Kutateladze, Hydromechanical model of the crisis of boiling under conditions of free convection, J. Tech. Phys. USSR. 20 (11) (1950) 1389-1392.
  10. M. Monde, H. Kusada, H. Uehara, Critical heat flux during natural convection boiling in vertical rectangular channels submerged in saturated liquid, ASME J. Heat Transfer 104 (1982) 300-303. https://doi.org/10.1115/1.3245087