References
- H.O. Anger, Scintillation camera, Review of Scientific Instruments 29 (1958) 27-33. https://doi.org/10.1063/1.1715998
- M.T. Madsen, Recent advances in SPECT imaging, Journal of Nuclear Medicine 48 (2007) 661-673. https://doi.org/10.2967/jnumed.106.032680
- R.J. Jaszczak, The early years of single photon emission computed tomography (SPECT): an anthology of selected reminiscences, Physics in Medicine and Biology 51 (2006) R99-R115.
- K. Ogawa, Image distortion and correction in single photon emission CT, Annals of Nuclear Medicine 18 (2004) 171-185. https://doi.org/10.1007/BF02984998
- Y.J. Lee, D.H. Kim, H.J. Kim, The effect of high-resolution parallel hole collimator materials with a pixelated semiconductor SPECT system at equivalent sensitivities: Monte Carlo simulation studies, Journal of the Korean Physical Society 64 (2014) 1055-1062.
- T.E. Peterson, L.R. Furenlid, SPECT detectors: The Anger camera and beyond, Physics in Medicine and Biology 26 (2011) R145-R182.
- B.D. Milbrath, A.J. Peurrung, M. Bliss, W.J. Weber, Radiation detector materials: An overview, Journal of Materials Re-search 23 (2008) 2561-2581. https://doi.org/10.1557/JMR.2008.0319
- M. Khoshakhlagh, J.P. Islamian, S.M. Abedi, B. Mahmoudian, Development of scintillators in nuclear medicine, World journal of Nuclear Medicine 14 (2015) 156-159. https://doi.org/10.4103/1450-1147.163241
- I. Mroi, T. Takayama, N. Motomura, The CdTe detector module and its imaging performance, Annals of Nuclear Medicine 15 (2001) 487-494. https://doi.org/10.1007/BF02988500
- M. Rizzi, M. D'Aloia, B. Castagnolo, Semiconductor detectors and principles of radiation-mater interaction, Journal of Applied Sciences 10 (2010) 3141-3155. https://doi.org/10.3923/jas.2010.3141.3155
- S. Del Sordo, L. Abbene, E. Caroli, A.M. Mancini, A. Zappettini, P. Ubertini, Progress in the development of CdTe and CdZnTe semiconductor radiation detectors for astrophysical and medical applications, Sensors 9 (2009) 3491-3526. https://doi.org/10.3390/s90503491
- O. Limousin, New trends in CdTe and CdZnTe detectors for X-and gamma-ray applications, Nuclear Instruments and Methods in Physics Research Section A 504 (2003) 24-37. https://doi.org/10.1016/S0168-9002(03)00745-9
- R.N. Beck, L.T. Zimmer, D.B. Charleston, P.B. Hoffer, Aspects of imaging and counting in nuclear medicine using scintillation and semiconductor detectors, IEEE Transactions on Nuclear Science 3 (1972) 173-178.
- H.B. Barber, Applications of semiconductor detectors to nuclear medicine, Nuclear Instruments and Methods in Physics Research Section A 436 (1999) 102-110. https://doi.org/10.1016/S0168-9002(99)00605-1
- C. Scheiber, G.C. Giakos, Medical applications of CdTe and CdZnTe detectors, Nuclear Instruments and Methods in Physics Research Section A 458 (2001) 12-25. https://doi.org/10.1016/S0168-9002(00)01032-9
- P.J. Sellin, Recent advances in compound semiconductor radiation detectors, Nuclear Instruments and Methods in Physics Research Section A 513 (2003) 332-339. https://doi.org/10.1016/j.nima.2003.08.058
- J.J. Griesmer, B. Kline, J. Hrosholz, K. Parnham, D. Gagnon, in: Performance evaluation of a new CZT detector for nuclear meidicne: Soltice, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310), 2002, pp. 1050-1054.
- L.K. Jambi, J.E. Lees, S.L. Bugby, S. Tipper, M.S. Alqahtani, A.C. Perkins, Evaluation of XRI-UNO CdTe detector for nuclear medical imaging, Journal of Instrumentation 10 (2015), P06012.
- K. Erlandsson, K. Kacperski, D.V. Gramberg, B.F. Hutton, Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology, Physics in Medicine and Biology 54 (2009) 2635-2649. https://doi.org/10.1088/0031-9155/54/9/003
- Y.J. Lee, H.J. Ryu, H.M. Cho, S.W. Lee, Y.N. Choi, H.J. Kim, Optimization of a high-resolution collimator for a CdTe detector: Monte Carlo simulation studies, Journal of the Korean Physical Society 60 (2012) 862-868. https://doi.org/10.3938/jkps.60.862
- T. Takahashi, S. Watanabe, Recent progress in CdTe and CdZnTe detectors, IEEE Transactions on Nuclear Science 48 (2001) 950-959. https://doi.org/10.1109/23.958705
- K. Ogawa, N. Ohmura, H. Iida, K. Nakamura, T. Nakahara, A. Kubo, Development of an ultra-high resolution SPECT system with a CdTe semiconductor detector, Annals of Nuclear Medicine 23 (2009) 763-770. https://doi.org/10.1007/s12149-009-0293-x
- L. Verger, M. Boitel, C. Gentet, R. Hamelin, C. Mestais, F. Mongellaz, J. Rustique, G. Sanchez, Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications, Nuclear Instruments and Methods in Physics Research Section A 458 (2001) 297-309. https://doi.org/10.1016/S0168-9002(00)00874-3
- S.J. Park, C.L. Lee, H.M. Cho, H.J. Kim, Ultra-high-resolution SPECT with CdTe for small-animal imaging applications: A Monte Carlo simulation study using a voxelized phantom, Journal of the Korean Physical Society 60 (2012) 1145-1149. https://doi.org/10.3938/jkps.60.1145
- K. Hitomi, T. Tada, S.Y. Kim, Y. Wu, T. Tanaka, T. Shoji, H. Yamazaki, K. Ishii, Recent development of TlBr Gamma-Ray detectors, IEEE Transactions on Nuclear Science 58 (2011) 1987-1991. https://doi.org/10.1109/TNS.2011.2123115
- D. Arino-Estrada, J. Du, H. Kim, L.J. Cirignano, K.S. Shah, S.R. Cherry, G.S. Mitchell, Development of TlBr detectors for PET imaging, Physics in Medicine and Biology 63 (2018), 13NT04.
- H. Kim, L. Cirignano, A. Churilov, G. Ciampi, W. Higgins, F. Olschner, K. Shah, Developing larger TlBr detec-tors-detector performance, IEEE Transactions on Nuclear Science 56 (2009) 819-823. https://doi.org/10.1109/TNS.2009.2014756
- K. Hitomi, T. Shoji, Y. Niizeki, A methods for suppressing polarization phenomena in TlBr detectors, Nuclear Instruments and Methods in Physics Research Section A 585 (2008) 102-104. https://doi.org/10.1016/j.nima.2007.11.012
- C.R. Park, S.H. Kang, Y. Lee, Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation simulation study, Nuclear Engineering and Technology 53 (2001) 1947-1954.
- J.S. Nabipour, A. Khorshidi, Spectroscopy and optimizing semiconductor detector data under X and g photons using im-age processing technique, Journal of Medical Imaging and Radiation Sciences 49 (2018) 194-200. https://doi.org/10.1016/j.jmir.2018.01.004
- S. Abbaspour, B. Mahmoudian, J.P. Islamian, Cadmium telluride semiconductor detector for improved spatial and energy resolution radioisotopic imaging, World Journal of Nuclear Medicine 16 (2017) 101-107. https://doi.org/10.4103/1450-1147.203079
- K. Hitomi, T. Shoji, K. Ishii, Advances in TlBr detector development, Journal of Crystal Growth 379 (2013) 93-98. https://doi.org/10.1016/j.jcrysgro.2013.03.002
- C.R. Park, S.H. Kang, Y. Lee, Optimization of mask size with median modified Wiener filter algorithm for gamma imag-es using pixelated semiconductor detector: Monte Carlo simulation study, Nuclear Instruments and Methods in Physics Research Section A 980 (2020), 164472.
- H.J. Ryu, Y.J. Lee, S.W. Lee, H.M. Cho, Y.N. Choi, H.J. Kim, Design of a high-resolution small-animal SPECT-CT system sharing a CdTe semiconductor detector, Journal of the Korean Physical Society 61 (2012) 130-134. https://doi.org/10.3938/jkps.61.130
- Y.J. Lee, S.J. Park, S.W. Lee, D.H. Kim, Y.S. Kim, H.J. Kim, Comparison of Photon Counting and Conventional Scintillation Detectors in a Pinhole SPECT System for Small Animal Imaging: Monte Carlo Simulation Studies, Journal of the Korean Physical Society 62 (2013) 1317-1322. https://doi.org/10.3938/jkps.62.1317
- M. Kolstein, G. Arino, M. Chmeissani, G.D. Lorenzo, Simulation of charge transport in pixelated CdTe, Journal of Instrumentation 9 (2014), C12027.