Abstract
Electric shutters for buildings are being developed in Korea and abroad on a regular basis and can be used in different types of buildings such as company buildings and fire stations, etc. However, the fall risk factors induced by a variety of functions of building electric shutters require safety control. We reviewed the technological trends and legal standards in Korea and abroad, analyzed incident cases, and identified fall risk factors requiring control. We inspected all the building electric shutters in Korea based on the fall risk factors. As a result, we identified 91 noncompliance cases, in 69 percent of all 132 locations. In this study, backed by the inspection results, we suggest a check list to prevent the fall of building electric shutters to ensure safety and conduct verification using a focus group interview.
건축물 전동셔터는 국·내외에서 주기적으로 발전하고 있으며, 회사, 소방서 등 다양한 건축물에서 사용이 가능하다. 건축물 전동셔터의 다양한 기능적인 부분에는 안전을 위협하는 추락 리스크 요인이 존재하며, 그 요인을 관리할 필요가 있다. 국·내외의 기술동향 및 법적기준을 분석하고, 사고사례를 분석하여 관리가 필요한 추락 리스크 요인을 도출하였다. 추락 리스크 요인을 기준으로 국내의 건축물 전동셔터를 전수 점검하였다. 건축물 전동셔터 132개소를 전수 점검해본 결과, 부적합 부위가 91개소 발견되었으며, 전체의 69%를 차지하고 있었다. 본 연구에서는 건축물 전동셔터의 안전을 위해 전수 점검을 기준으로 건축물 전통셔터의 추락방지 체크리스트를 제안하고 표적 집단면접을 통하여 검증하였다.