Abstract
Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.
목 적: 양측 유방암 방사선치료 시 토모테라피와 Halcyon 선형가속기을 이용한 치료계획을 비교하여 Halcyon 치료 계획의 유용성을 평가. 대상 및 방법: 양측 유방암 환자 10명을 대상으로 Helical Mode를 사용하여 조사면 고정 너비(Field Width, FW) 5.0-cm, 피치(Pitch) 0.287, 변조 지수(Modulation Factor) 2.4 조건의 토모테라피(Helical Tomotherapy, Accuray, USA)와 6Arc 및 8Arc의 Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA)을 이용한 용적변조회전치료(Volumetric Modulated Arc Therapy, VMAT)치료계획을 수립하였다. 총 처방 선량 42.4Gy/16회로 치료계획용적(Planning Target Volume, PTV)의 V 40.3Gy이 90% 이상이 되도록 하였다. 종양 및 정상 장기의 선량을 비교하여 치료 계획의 질을 평가하였고 Total MU와 Beam On Time을 비교하여 효율성을 평가하였다. 결 과: 대상 환자들의 3개 치료계획 (Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT)의 평가 항목 평균 값은 PTV의 H.I (Homogeneity Index)는 각각 1.07, 1.10, 1.11, PTV의 C.I (Conformity Index)는 각각 1.21, 1.16, 1.17 이었다. 정상 장기의 선량 평가 항목 평균 값은 BOTH LUNG의 V 5Gy는 각각 36.3%, 31.2%, 29.7% 이며, V 15Gy는 각각 18.6%, 15.5%, 14.6% 이었다. HEART의 평균 선량(Gy)은 각각 4.17, 2.69, 2.51 이었다. Total MU의 평균 값은 각각 7498.6, 2494.2, 2471.5 이며 Beam On Time (sec)의 평균 값은 각각 462.5, 195.4, 198 로 토모테라피와 비교하여 Halcyon VMAT 치료계획이 Beam On Time과 Total MU가 감소하였다. 결 론: Halcyon VMAT은 토모테라피와 비교하였을 때 유사한 치료 계획의 질을 보여주며 정상 장기의 더 높은 보호 효과를 나타내었다. 또한 Beam On Time과 Total MU의 감소로 방사선치료의 효율성이 증가하였다.