Acknowledgement
This work is supported by Nuclear Safety Research Program through the Korea Foundation of Nuclear Safety (KoFONS) using the financial resource granted by the Nuclear Safety and Security Commission (NSSC) of the Republic of Korea (No. 2204019).
References
- International Atomic Energy Agency. PRIS Power Reactor Information System: age distribution [Internet]. Vienna, Austria: International Atomic Energy Agency; 2020 [cited 2022 Dec 20]. Available from: https://pris.iaea.org/pris/worldstatistics/operationalbyage.aspx.
- Mladenov A, Stankov D, Nonova T, Krezhov K. Radiation protection, radioactive waste management and site monitoring at the nuclear scientific experimental and educational centre IRTSofia at INRNE-BAS. Radiat Prot Dosimetry. 2014;162(1-2):176-181. https://doi.org/10.1093/rpd/ncu254
- Ziock KP, Collins JW, Fabris L, Gallagher S, Horn BK, Lanza RC, et al. Source-search sensitivity of a large-area, coded-aperture, gamma-ray imager. IEEE Trans Nucl Sci. 2006;3(3):1614-1621.
- Cieslak MJ, Gamage KA, Glover R. Coded-aperture imaging systems: past, present and future development: a review. Radiat Meas. 2016;92:59-71.
- Wahl CG, Kaye WR, Wang W, Zhang F, Jaworski JM, King A, et al. The Polaris-H imaging spectrometer. Nucl Instrum Methods Phys Res A. 2015;784:377-381. https://doi.org/10.1016/j.nima.2014.12.110
- Vetter K, Barnowksi R, Haefner A, Joshi TH, Pavlovsky R, Quiter BJ. Gamma-ray imaging for nuclear security and safety: towards 3-D gamma-ray vision. Nucl Instrum Methods Phys Res A. 2018; 878:159-168. https://doi.org/10.1016/j.nima.2017.08.040
- Amgarou K, Paradiso V, Patoz A, Bonnet F, Handley J, Couturier P, et al. A comprehensive experimental characterization of the iPIX gamma imager. J Instrum. 2016;11(08):P08012. https://doi.org/10.1088/1748-0221/11/08/P08012
- Montemont G, Bohuslav P, Dubosq J, Feret B, Monnet O, Oehling O, et al. NuVISION: a portable multimode gamma camera based on HiSPECT imaging module. Atlanta, GA: Proceedings of 2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC); 2017 Oct 21-28; Atlanta. GA. pp. 1-3.
- International Atomic Energy Agency. 2016 Technology Demonstration Workshop (TDW) on gamma imaging-external [Internet]. Vienne, Austria: International Atomic Energy Agency; 2017 [cited 2022 Dec 20]. Available from: https://phdsco.com/wpcontent/uploads/2020/04/2016_Technology_Demonstration_Workshop_TDW_on_Gamma_Imaging-External.pdf.
- Jeong M, Van B, Wells BT, Lawrence JD, Hammig MD. Comparison between pixelated scintillators: CsI(Tl), LaCl3(Ce) and LYSO(Ce) when coupled to a silicon photomultipliers array. Nucl Instrum Methods Phys Res A. 2018;893:75-83. https://doi.org/10.1016/j.nima.2018.03.024
- Epic-Crystal. BGO scintillator [Internet]. Kunshan, China: Epic-Crystal Ltd.; 2021 [cited 2022 Dec 20]. Available from: https://www.epic-crystal.com/download-center/index_2.html.
- Joshi S. Coded aperture imaging applied to pixelated CdZnTe detectors [dissertation]. Ann Arbor, MI: University of Michigan; 2014.
- Jeong M, Hammig MD. Comparison of gamma ray localization using system matrixes obtained by either MCNP simulations or ray-driven calculations for a coded-aperture imaging system. Nucl Instrum Methods Phys Res A. 2020;954:161353. https://doi.org/10.1016/j.nima.2018.10.031
- Semiconductor Components Industries. Silicon potomultipliers (SiPM) [Internet]. Phoenix, AZ: Semiconductor Components Industries; 2021 [cited 2022 Dec 20]. Available from: https://www.onsemi.com/products/sensors/photodetectors-sipmspad/silicon-photomultipliers-sipm.
- Jeong M, Van B, Wells BT, D'Aries LJ, Hammig MD. Scalable gamma-ray camera for wide-area search based on silicon photomultipliers array. Rev Sci Instrum. 2018;89(3):033106. https://doi.org/10.1063/1.5016563
- Park S, Boo J, Hammig M, Jeong M. Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras. Nuclear Engineering and Technology. 2021;53 (4):1266-1276. https://doi.org/10.1016/j.net.2020.09.012
- Yoshino M. Study on a novel Compton-PET hybrid camera using newly developed scintillators for simultaneous imaging of PET/SPECT application [dissertation]. Sendai, Japan: Tohoku University; 2018.
- Jeong M, Hammig M. Development of hand-held coded-aperture gamma ray imaging system based on GAGG (Ce) scintillator coupled with SiPM array. Nucl Eng Technol. 2020;52(11): 2572-2580. https://doi.org/10.1016/j.net.2020.04.009
- Yan Y, Cao W, Li S. Block-based adaptive image watermarking scheme using just noticeable difference. Proceedings of 2009 IEEE International Workshop on Imaging Systems and Techniques; 2009 May 11-12; Shenzhen, China. pp. 377-380.
- Hore A, Ziou D. Image quality metrics: PSNR vs. SSIM. Proceedings of 2010 20th International Conference on Pattern Recognition; 2010 Aug 23-26; Istanbul, Turkey. pp. 2366-2369.
- Wang Z, Bovik AC, Sheikh HR, Simoncelli EP. Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process. 2004;13(4):600-612. https://doi.org/10.1109/TIP.2003.819861