Acknowledgement
Work for this paper is supported by Natural Science Foundation of China (NSFC) through Grant Nos. 5180081528 and 51978351. Herewith acknowledge with best thanks.
References
- Ahn, J.H., Kim, S.H. and Jeong, Y.J. (2008), "Shear behaviour of perfobond rib shear connector under static and cyclic loadings", Mag. Concrete Res., 60(5), 347-357. DOI: https://doi.org/10.1680/macr.2007.00046.
- Ahn, J.H., Lee, C.G., Won, J.H. and Kim, S.H. (2010), "Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement", J. Construct. Steel Res., 66(10), 1295-1307. https://doi.org/10.1016/j.jcsr.2010.04.008.
- Allahyari, H., Dehestani, M., Beygi, M.H.A., Neya, B.N. and Rahmani, E. (2014), "Mechanical behavior of steel-concrete composite decks with perfobond shear connectors", Steel Compos. Struct., 17(3). 339-358. https://doi.org/10.12989/scs.2014.17.3.339.
- Allahyari, H., Nikbin, I.M., Rahimi, R.S. and Heidarpour, A. (2018), "A new approach to determine strength of Perfobond rib shear connector in steel-concrete composite structures by employing neural network", Eng. Struct., 157, 235-249. https://doi.org/10.1016/j.engstruct.2017.12.007.
- Andra, H.P. (1990), "Economical shear connectors with high fatigue strength", IABSE Symposium, 67-172, Brussels.
- Bursi, O.S. and Sun, F. and Postal, S. (2010), "Non-linear analysis of steel-concrete composite frames with full and partial shear connection subjected to seismic loads", J. Construct. Steel Res., 61(1). 67-92. https://doi.org/10.1016/j.jcsr.2004.06.002.
- Candido-Martins, J.P.S., Costa-Neves, L.F. and Vellasco, P.C.G.D. (2010), "Experimental evaluation of the structural response of Perfobond shear connectors", Eng. Struct., 32(8). 1976-1985. https://doi.org/10.1016/j.engstruct.2010.02.031.
- Cho, J.R., Park, S.Y., Cho, K., Kim, S.T. and Kim, B.S. (2012), "Pull-out test and discrete spring model of fiber-reinforced polymer perfobond rib shear connector", Canadian J. Civil Eng., 39(12), 1311-1320. https://doi.org/10.1139/cjce-2011-0573.
- Chung, C.H., Lee, J. and Kim, J.S. (2016), "Shear Strength of T-type Perfobond Rib Shear Connectors", KSCE J. Civil Eng., 20(5), 1824-1834. https://doi.org/10.1007/s12205-015-0095-8.
- Deng, W.Q., Gu, J.C., Liu, D., Hu, J. and Zhang, J.D. (2019), "Study of single perfobond rib with head stud shear connectors for a composite structure", Mag. Concrete Res., 71(17), 920-934. https://doi.org/10.1680/jmacr.18.00051.
- Di, J., Zou, Y., Zhou, X.H., Qin, F.J. and Peng, X. (2018), "Push-out test of large perfobond connectors in steel-concrete joints of hybrid bridges", J. Construct. Steel Res., 150, 415-429. https://doi.org/10.1016/j.jcsr.2018.09.002.
- Dietrich, M.Z. and Calenzani, A.F.G. and Fakury, R.H. (2019), "Analysis of rotational stiffness of steel-concrete composite beams for lateral-torsional buckling", Eng. Struct., 198, 109554. https://doi.org/10.1016/j.engstruct.2019.109554.
- Eurocode 4, E.N. (2004), Design of Composite Steel and Concrete Structures. Part 1.1: General Rules and Rules for Buildings, BSI Publications, London.
- GB50017 (2017), Standard for Design of Steel Structures. GB50017-2017, China Building Industry Press, Beijing.
- GB50917 (2013), Code for Design of Steel and Concrete Composite Bridges. GB50917-2013, China Building Industry Press, Beijing.
- Giussani, F. and Mola, F. (2006), "Service-stage analysis of curved composite steel-concrete bridge beams", J. Struct. Eng.- ASCE, 132(12), 1928-1939. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:12(1928).
- Gu, J.C., Liu, D., Deng, W.Q. and Zhang, J.D. (2019), "Experimental study on the shear resistance of a comb-type perfobond rib shear connector", J. Construct. Steel Res., 158, 279-289. https://doi.org/10.1016/j.jcsr.2019.03.032.
- He, S.H., Fang, Z., Fang, Y.W., Liu, M., Liu, L.Y. and Mosallam, A.S. (2016), "Experimental study on perfobond strip connector in steel-concrete joints of hybrid bridges", J. Construct. Steel Res., 118, 169-179. https://doi.org/10.1016/j.jcsr.2015.11.009.
- He, S.H., Fang, Z. and Mosallam, A.S. (2017), "Push-out tests for perfobond strip connectors with UHPC grout in the joints of steel-concrete hybrid bridge girders", Eng. Struct., 135, 177-190. https://doi.org/10.1016/j.engstruct.2017.01.008.
- Hosaka, T., Mitsugi, K., Hiragi, H. and Ushijima, H. (2002), "Study on shear strength and design method of perfobond strip", Japan. J. Struct. Eng., 48, 1265-1272.
- Hu, J.H., Ye, M.X. and Huang, Q. (2006), "Experiment on bearing capacity of PBL shear connectors", China J. Highway Transport, 19(6), 65-72. https://doi.org/10.3321/j.issn:1001-7372.2006.06.013.
- Kim, K.S., Han, O., Choi, J. and Kim, S.H. (2019a), "Hysteretic performance of stubby Y-type perfobond rib shear connectors depending on transverse rebar", Construct. Build. Mater., 200, 64-79. https://doi.org/10.1016/j.conbuildmat.2018.12.070.
- Kim, K.S., Han, O., Gombosuren, M. and Kim, S.H. (2019b), "Numerical simulation of Y-type perfobond rib shear connectors using finite element analysis", Steel Compos. Struct., 31(1), 53-67. https://doi.org/10.12989/scs.2019.31.1.053.
- Kim, S.H., Choi, J., Park, S.J., Ahn, J.H. and Jung, C.Y. (2014), "Behavior of composite girder with Y-type perfobond rib shear connectors", J. Construct. Steel Res., 103, 275-289. https://doi.org/10.1016/j.jcsr.2014.09.012.
- Kim, S.H., Choi, K.T., Park, S.J., Park, S.M. and Lung, C.Y. (2013), "Experimental shear resistance evaluation of Y-type perfobond rib shear connector", J. Construct. Steel Res., 82, 1-18. https://doi.org/10.1016/j.jcsr.2012.12.001.
- Kim, S.H., Han, O., Kim, K.S. and Park, J.S. (2018), "Experimental behavior of double-row Y-type perfobond rib shear connectors", J. Construct. Steel Res., 150, 221-229. https://doi.org/10.1016/j.jcsr.2018.08.012.
- Kim, S.H., Kim, K.S., Lee, D.H., Park, J.S. and Han, O. (2017a), "Analysis of the shear behavior of stubby Y-type perfobond rib shear connectors for a composite frame structure", Materials, 10(11). https://doi.org/10.3390/ma10111340.
- Kim, S.H., Kim, K.S., Park, S., Aim, J.H. and Lee, M.K. (2016), "Y-type perfobond rib shear connectors subjected to fatigue loading on highway bridges", J. Construct. Steel Res., 122, 445-454. https://doi.org/10.1016/j.jcsr.2016.04.015.
- Kim, S.H., Park, S., Kim, K.S. and Jung, C.Y. (2017b), "Generalized formulation for shear resistance on Y-type perfobond rib shear connectors", J. Construct. Steel Res., 128, 245-260. https://doi.org/10.1016/j.jcsr.2016.08.016.
- Klingner, R.E. and Mendonca, J.A. (1982), "Tensile capacity of short anchor bolts and welded studs - a literature-review", J. Amer. Concrete Institute, 79(4), 270-279. https://doi.org/10.14359/10897.
- Leonhardt, F., Andrae, W., Andrae, H.P. and Harre, W. (1989), "New, improved bonding means for composite load bearing structures with high fatigue strength", Int. J. Fatigue, 11(6), 449.
- Li, Z.X., Zhao, C.H., Deng, K.L. and Wang, W.A. (2018), "Load sharing and slip distribution in multiple holes of a perfobond rib shear connector", J. Struct. Eng., 144(9). https://doi.org/10.1061/(ASCE)st.1943-541x.0002152.
- Liu, X.P., Bradford, M.A. and Ataei, A. (2017), "Flexural performance of innovative sustainable composite steel-concrete beams", Eng. Struct., 130, 282-296. https://doi.org/10.1016/j.engstruct.2016.10.009.
- Medberry, S.B. (2002), "Perfobond shear connector for composite construction", Eng. J., 39.
- Mirza, O. and Uy, B. (2010), "Effects of the combination of axial and shear loading on the behaviour of headed stud steel anchors", Eng. Struct., 32(1), 93-105. https://doi.org/10.1016/j.engstruct.2009.08.019.
- Oehlers, D. and Coughlan, C. (1986), "The shear stiffness of stud shear connections in composite beams", J. Construct. Steel Res., 6(4), 273-284. https://doi.org/10.1016/0143-974X(86)90008-8.
- Oguejiofor, E.C. and Hosain, M.U. (1992), "Behavior of perfobond rib shear connectors in composite beams - full-size tests", Canadian J. Civil Eng., 19(2), 224-235. https://doi.org/10.1139/l92-028.
- Oguejiofor, E.C. and Hosain, M.U. (1994), "A Parametric Study of Perfobond Rib Shear Connectors", Canadian J. Civil Eng., 21(4), 614-625. https://doi.org/10.1139/l94-063.
- Oguejiofor, E.C. and Hosain, M.U. (1995), "Tests of Full-Size Composite Beams with Perfobond Rib Connectors", Canadian J. Civil Eng., 22(1), 80-92. https://doi.org/10.1139/l95-008.
- Oguejiofor, E.C. and Hosain, M.U. (1997), "Numerical analysis of push-out specimens with perfobond rib connectors", Comput. Struct., 62(4), 617-624. https://doi.org/10.1016/S0045-7949(96)00270-2.
- Ros, M. (1934), "Les constructions acier-beton systeme Alpha", L'Ossature Metallique (Bruxelles), 3(4), 195-208.
- Rodrigues, J.P.C. and Laim, L. (2011), "Behaviour of Perfobond shear connectors at high temperatures", Eng. Struct., 33(10), 2744-2753. https://doi.org/10.1016/j.engstruct.2011.05.004.
- Rodrigues, J.P.C. and Laim, L. (2014), "Experimental investigation on the structural response of T, T-block and TPerfobond shear connectors at elevated temperatures", Eng. Struct., 75, 299-314. https://doi.org/10.1016/j.engstruct.2014.06.016.
- Shim, C.S., Lee, P.G. and Yoon, T.Y. (2004), "Static behavior of large stud shear connectors", Eng. Struct., 26(12), 1853-1860. https://doi.org/10.1016/j.engstruct.2004.07.011.
- Su, Q.T., Wang, W., Luan, H.W. and Yang, G.T. (2014a), "Experimental research on bearing mechanism of perfobond rib shear connectors", J. Construct. Steel Res., 95, 22-31. https://doi.org/10.1016/j.jcsr.2013.11.020.
- Su, Q.T., Yang, G.T. and Bradford, M.A. (2016), "Bearing Capacity of Perfobond Rib Shear Connectors in Composite Girder Bridges", J. Bridge Eng., 21(4). https://doi.org/10.1061/(ASCE)BE.1943-5592.0000865.
- Su, Q.T., Yang, G.T. and Li, C.X. (2014b), "Structural behaviour of perforated shear connectors with flange heads in composite girders: an experimental approach", Int. J. Steel Struct., 14(1), 151-164. https://doi.org/10.1007/s13296-014-1013-5.
- Su, Q.T., Yang, G.T. and Wu, C. (2012), "Experimental investigation on inelastic behavior of composite box girder under negative moment", Int. J. Steel Struct., 12(1), 71-84. https://doi.org/10.1007/s13296-012-1007-0.
- Vianna, J.D., Costa-Neves, L.F., Vellasco, P.C.G. and de Andrade, S.A.L. (2009), "Experimental assessment of Perfobond and T-Perfobond shear connectors' structural response", J. Construct. Steel Res., 65(2), 408-421. https://doi.org/10.1016/j.jcsr.2008.02.011.
- Vianna, J.D., Costa-Neves, L.F., Vellasco, P.C.G.D. and de Andrade, S.A.L. (2008), "Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach", Eng. Struct., 30(9), 2381-2391. https://doi.org/10.1016/j.engstruct.2008.01.015.
- Vianna, J.D., de Andrade, S.A.L., Vellasco, P.C.G.D. and Costa-Neves, L.F. (2013), "Experimental study of Perfobond shear connectors in composite construction", J. Construct. Steel Res., 81, 62-75. https://doi.org/10.1016/j.jcsr.2012.11.002.
- Viest, I.M. (1956), "Investigation of Stud Shear Connectors for Composite Concrete and Steel T-Beams", J. Amer. Concrete Institute, 27(8), 875-891. https://doi.org/10.14359/11655.
- Wang, B., Huang, Q. and Liu, X.L. (2019a), "Comparison of static and fatigue behaviors between stud and perfobond shear connectors", KSCE J. Civil Eng., 23(1), 217-227. https://doi.org/10.1007/s12205-018-1303-0.
- Wang, Q. (2013), Experimental Research on Mechanical Behavior and Design Method of Stud Connectors, Ph.D. Dissertation, Department of Bridge Engineering, College of Civil Engineering, Tongji University, Shanghai, China.
- Wang, X.Z., Liu, Y.Q. and Liu, Y.Q. (2019b), "Experimental study on shear behavior of notched long-hole perfobond connectors", Adv. Struct. Eng., 22(1), 202-213. https://doi.org/10.1177/1369433218782991.
- Wang, Y.C. (1998), "Deflection of steel-concrete composite beams with partial shear interaction", J. Struct. Eng., 124(10), 1159-1165. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:10(1159).
- Wang, Z.H., Li, Q. and Zhao, C.H. (2013), "Ultimate shear resistance of perfobond rib shear connectors based on a modified push-out test", Adv. Struct. Eng., 16(4), 667-680. https://doi.org/10.1260/1369-4332.16.4.667.
- Xiao, L., Li, X. and John Ma, Z. (2017), "Behavior of perforated shear connectors in steel-concrete composite joints of hybrid bridges", J. Bridge Eng., 22(4). https://doi.org/10.1061/(ASCE)BE.1943-5592.0001020.
- Yang, G.T. and Su, Q.T. (2011), "Discussion on composite (steel-concrete) highway bridge fatigue assessment", J. Construct. Steel Res., 67(9), 1411-1412. https://doi.org/10.1016/j.jcsr.2011.03.002
- Yang, G.T. and Su, Q.T. (2012), "Discussion on numerical simulation of concrete encased steel composite columns", J. Construct. Steel Res., 71, 263-264. https://doi.org/10.1016/j.jcsr.2011.09.013.
- Zhang, Q., Jia, D., Bao, Y., Cheng, Z., Xiao, L. and Bu, Y. (2018), "Internal force transfer effect-based fatigue damage evaluation for PBL shear connector groups", J. Construct. Steel Res., 148, 469-478. https://doi.org/10.1016/j.jcsr.2018.06.016.
- Zhang, Q.H., Jia, D.L., Bao, Y., Cheng, Z.Y., Bu, Y.Z. and Li, Q. (2017a), "Analytical study on internal force transfer of perfobond rib shear connector group using a nonlinear spring model", J. Bridge Eng., 22(10). https://doi.org/10.1061/(ASCE)be.1943-5592.0001123.
- Zhang, Q.H., Pei, S.L., Cheng, Z.Y., Bao, Y. and Li, Q. (2017b), "Theoretical and experimental studies of the internal force transfer mechanism of perfobond rib shear connector group", J. Bridge Eng., 22(2). https://doi.org/10.1061/(ASCE)BE.1943-5592.0000997.
- Zhao, C. (2013), Research on Shear Capacity and Deformation Property of Perfobond Connectors, Ph.D. Dissertation, Department of Bridge Engineering, College of Civil Engineering, Tongji University, Shanghai, China.
- Zheng, S.J. and Liu, Y.Q. (2014), "Experiment of initial shear stiffness of perfobond connector", China J. Highway Transport, 27(11), 69-75.
- Zheng, S.J., Liu, Y.Q., Liu, Y.Q. and Zhao, C. (2019), "Experimental and numerical study on shear resistance of notched perfobond shear connector", Materials, 12(3). https://doi.org/10.3390/ma12030341.