Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in "Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed." The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.

Keywords

Acknowledgement

본 연구는 국토교통부/국토교통과학기술진흥원의 지원으로 수행되었음(과제번호 21CTAP-C152105-03)

References

  1. FEMA P-774. Unreinforced Masonry Buildings and Earthquakes; FEMA:Washington, DC, USA. c2009.
  2. Doogangun A, Ural A, Livaooglu R. Seismic performance of masonry buildings during recent earthqukes in Turkey. In Proceedings of the 14th World Conference on Earthquake Engineering (14WCEE); 2008 Oct 12-17; Beijing, jjChina. c2008. pp. 1-8.
  3. Kim TW, Min CG, Lee HM. Seismic Performance Evaluation of Unreinforced Masonry Buildings By Using a Three-Step Procedure. EESK J Earthquake Eng. 2011 Jun;15(3):57-64.
  4. Seol YJ, Park JH. Seismic Performance Evaluation of Unreinforced Masonry Buildings Retrofitted by Strengthening External Walls. EESK J Earthquake Eng. 2020 Mar;24(2):19-29.
  5. Bae BI, Yun HJ, Choi CS, Choi HK. Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet. J of the KCI. 24(3):305-313.
  6. Mustafaraj E, Yardim Y. In-plane shear strengthening of unreinforced masonry walls using GFRP jacketing. Period Polytech Civ Eng. 2018;62:330-336.
  7. D'Ambrisi A, Mezzi M, Caporale A. Experimental investigation on polymeric net-RCM reinforced masonry panels. Compos Struct. 2013;105:207-215. https://doi.org/10.1016/j.compstruct.2013.05.017
  8. Almeida JAPP, Pereira ENB, Barros JAO. Assessment of overlay masonry strengthening system under in-plane monotonic and cyclic loading using the diagonal tensile test. Constr Build Mater. 2015;94:851-865. https://doi.org/10.1016/j.conbuildmat.2015.07.040
  9. Yu JH, Park JH. Investigation of Steel Fiber-Reinforced Mortar Overlay for Strengthening Masonry Walls by Prism Tests. Appl Sci. 2020;10:6395. https://doi.org/10.3390/app10186395
  10. Ismail N, Petersen RB, Masia MJ, Ingham JM. Diagonal shear behavior of unreinforced masonry wallettes strengthened using twisted steel bars. Constr Build Mater. 2011;25:4386-4393. https://doi.org/10.1016/j.conbuildmat.2011.04.063
  11. Taghdi M, Bruneau M, Saatcioglu M. Seismic retrofitting of lowrise masonry and concrete walls using steel strips. ASCE J Struct Eng. 2000;126:1017-1025. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:9(1017)
  12. Yang KH, Mun JH, Hwang SH. Cyclic shear behavior of masonry walls strengthened with prestressed steel bars and glass fiber grids. Compos Struct. 2020;238:1-12.
  13. Korea Authority of Land & Infrastructure Safety. Guidelines for seismic performance evaluation for existing buildings. 11-B552016-000035-14. c2021.
  14. American Society of Civil Engineers. ASCE 41-17 Seismic Evalution and Retrofitting Techniques for Unreinforced Masonry Buildings. c2017
  15. Ministry of Land and Transportation. Seismic Design in General. KDS 17 10 00. Korea Construction Standards Center. c2019.