DOI QR코드

DOI QR Code

Effectiveness of low-level laser therapy and chewing gum in reducing orthodontic pain: A randomized controlled trial

  • Celebi, Fatih (Department of Orthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University) ;
  • Bicakci, Ali Altug (Department of Orthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University) ;
  • Kelesoglu, Ufuk (Department of Orthodontics, Faculty of Dentistry, Tokat Gaziosmanpasa University)
  • Received : 2020.10.20
  • Accepted : 2021.01.29
  • Published : 2021.09.25

Abstract

Objective: The purpose of this study was to evaluate the effects of chewing gum and low-level laser therapy in alleviating orthodontic pain induced by the initial archwire. Methods: Patients with 3-6 mm maxillary crowding who planned to receive non-extraction orthodontic treatment were recruited for the study. Sixty-three participants (33 females and 30 males) were randomly allocated into three groups: laser, chewing gum, and control. In the laser group, a gallium aluminum arsenide (GaAlAs) diode laser with a wavelength of 820 nm was used to apply a single dose immediately after orthodontic treatment began. In the chewing gum group, sugar-free gum was chewed three times for 20 minutes-immediately after starting treatment, and at the twenty-fourth and forty-eighth hours of treatment. Pain perception was measured using a visual analog scale at the second, sixth, and twenty-fourth hours, and on the second, third, and seventh days. Results: There were no statistically significant differences between the groups at any measured time point (p > 0.05). The highest pain scores were detected at the twenty-fourth hour of treatment in all groups. Conclusions: Within the limitations of the study, we could not detect whether low-level laser therapy and chewing gum had any clinically significant effect on orthodontic pain. Different results may be obtained with a higher number of participants or using lasers with different wavelengths and specifications. Although the study had a sufficient number of participants according to statistical analysis, higher number of participants could have provided more definitive outcomes.

Keywords

References

  1. Krishnan V. Orthodontic pain: from causes to management--a review. Eur J Orthod 2007;29:170-9. https://doi.org/10.1093/ejo/cjl081
  2. Erdinc AM, Dincer B. Perception of pain during orthodontic treatment with fixed appliances. Eur J Orthod 2004;26:79-85. https://doi.org/10.1093/ejo/26.1.79
  3. Bergius M, Kiliaridis S, Berggren U. Pain in orthodontics. A review and discussion of the literature. J Orofac Orthop 2000;61:125-37. https://doi.org/10.1007/BF01300354
  4. Bergius M, Berggren U, Kiliaridis S. Experience of pain during an orthodontic procedure. Eur J Oral Sci 2002;110:92-8. https://doi.org/10.1034/j.1600-0722.2002.11193.x
  5. Lew KK. Attitudes and perceptions of adults towards orthodontic treatment in an Asian community. Community Dent Oral Epidemiol 1993;21:31-5. https://doi.org/10.1111/j.1600-0528.1993.tb00715.x
  6. O'Connor PJ. Patients' perceptions before, during, and after orthodontic treatment. J Clin Orthod 2000;34:591-2.
  7. Maquet D, Croisier JL, Demoulin C, Crielaard JM. Pressure pain thresholds of tender point sites in patients with fibromyalgia and in healthy controls. Eur J Pain 2004;8:111-7. https://doi.org/10.1016/S1090-3801(03)00082-X
  8. Park G, Kim CW, Park SB, Kim MJ, Jang SH. Reliability and usefulness of the pressure pain threshold measurement in patients with myofascial pain. Ann Rehabil Med 2011;35:412-7. https://doi.org/10.5535/arm.2011.35.3.412
  9. Lim HM, Lew KK, Tay DK. A clinical investigation of the efficacy of low level laser therapy in reducing orthodontic postadjustment pain. Am J Orthod Dentofacial Orthop 1995;108:614-22. https://doi.org/10.1016/S0889-5406(95)70007-2
  10. Schultz RJ, Krishnamurthy S, Thelmo W, Rodriguez JE, Harvey G. Effects of varying intensities of laser energy on articular cartilage: a preliminary study. Lasers Surg Med 1985;5:577-88. https://doi.org/10.1002/lsm.1900050606
  11. Balboni GC, Brandi ML, Zonefrati R, Repice F. Effects of He-Ne/I. R. laser irradiation on two lines of normal human fibroblasts in vitro. Arch Ital Anat Embriol 1986;91:179-88.
  12. Harris DM. Editorial comment biomolecular mechanisms of laser biostimulation. J Clin Laser Med Surg 1991;9:277-80. https://doi.org/10.1089/clm.1991.9.277
  13. Mester E, Mester AF, Mester A. The biomedical effects of laser application. Lasers Surg Med 1985; 5:31-9. https://doi.org/10.1002/lsm.1900050105
  14. Shirazi M, Ahmad Akhoundi MS, Javadi E, Kamali A, Motahhari P, Rashidpour M, et al. The effects of diode laser (660 nm) on the rate of tooth movements: an animal study. Lasers Med Sci 2015;30:713-8. https://doi.org/10.1007/s10103-013-1407-1
  15. Bicakci AA, Kocoglu-Altan B, Toker H, Mutaf I, Sumer Z. Efficiency of low-level laser therapy in reducing pain induced by orthodontic forces. Photomed Laser Surg 2012;30:460-5. https://doi.org/10.1089/pho.2012.3245
  16. Doshi-Mehta G, Bhad-Patil WA. Efficacy of low-intensity laser therapy in reducing treatment time and orthodontic pain: a clinical investigation. Am J Orthod Dentofacial Orthop 2012;141:289-97. https://doi.org/10.1016/j.ajodo.2011.09.009
  17. Benson PE, Razi RM, Al-Bloushi RJ. The effect of chewing gum on the impact, pain and breakages associated with fixed orthodontic appliances: a randomized clinical trial. Orthod Craniofac Res 2012; 15:178-87. https://doi.org/10.1111/j.1601-6343.2012.01546.x
  18. Alqareer A, Alyahya A, Al-Anezi SA, AlAwadhi A, Al Qabandi S, Alyaseen M. Efficacy of chewing gum to reduce orthodontic pain compared to placebo: a blinded, parallel-group, preliminary clinical trial. J Oral Facial Pain Headache 2019;33:301-7. https://doi.org/10.11607/ofph.2192
  19. Kinser AM, Sands WA, Stone MH. Reliability and validity of a pressure algometer. J Strength Cond Res 2009;23:312-4. https://doi.org/10.1519/JSC.0b013e31818f051c
  20. Jayaseelan DJ, Cole KR, Courtney CA. Hand-held dynamometer to measure pressure pain thresholds: a double-blinded reliability and validity study. Musculoskelet Sci Pract 2021;51:102268. https://doi.org/10.1016/j.msksp.2020.102268
  21. Matys J, Jaszczak E, Flieger R, Kostrzewska-Kaminiarz K, Grzech-Lesniak K, Dominiak M. Effect of ozone and diode laser (635 nm) in reducing orthodontic pain in the maxillary arch-a randomized clinical controlled trial. Lasers Med Sci 2020;35:487-96. https://doi.org/10.1007/s10103-019-02896-0
  22. Proffit WR. Contemporary orthodontics. 3rd ed. St. Louis: Mosby; 2000.
  23. Celebi F, Turk T, Bicakci AA. Effects of low-level laser therapy and mechanical vibration on orthodontic pain caused by initial archwire. Am J Orthod Dentofacial Orthop 2019;156:87-93. https://doi.org/10.1016/j.ajodo.2018.08.021
  24. Farzanegan F, Zebarjad SM, Alizadeh S, Ahrari F. Pain reduction after initial archwire placement in orthodontic patients: a randomized clinical trial. Am J Orthod Dentofacial Orthop 2012;141:169-73. https://doi.org/10.1016/j.ajodo.2011.06.042
  25. Ireland AJ, Ellis P, Jordan A, Bradley R, Ewings P, Atack NE, et al. Comparative assessment of chewing gum and ibuprofen in the management of orthodontic pain with fixed appliances: a pragmatic multicenter randomized controlled trial. Am J Orthod Dentofacial Orthop 2016;150:220-7. https://doi.org/10.1016/j.ajodo.2016.02.018
  26. Miles P, Smith H, Weyant R, Rinchuse DJ. The effects of a vibrational appliance on tooth movement and patient discomfort: a prospective randomised clinical trial. Aust Orthod J 2012;28:213-8.
  27. Lobre WD, Callegari BJ, Gardner G, Marsh CM, Bush AC, Dunn WJ. Pain control in orthodontics using a micropulse vibration device: a randomized clinical trial. Angle Orthod 2016;86:625-30. https://doi.org/10.2319/072115-492.1
  28. Marie SS, Powers M, Sheridan JJ. Vibratory stimulation as a method of reducing pain after orthodontic appliance adjustment. J Clin Orthod 2003;37:205-8; quiz 203-4.
  29. Ngan P, Kess B, Wilson S. Perception of discomfort by patients undergoing orthodontic treatment. Am J Orthod Dentofacial Orthop 1989;96:47-53. https://doi.org/10.1016/0889-5406(89)90228-X
  30. Scheurer PA, Firestone AR, Burgin WB. Perception of pain as a result of orthodontic treatment with fixed appliances. Eur J Orthod 1996;18:349-57. https://doi.org/10.1093/ejo/18.1.349

Cited by

  1. Literature Watch September 2021 vol.39, pp.12, 2021, https://doi.org/10.1089/photob.2021.0152