과제정보
This study was supported by a grant of the Korea Institute of Radiological and Medical Sciences (KIRAMS), funded by the Ministry of Science and ICT (MIST), Republic of Korea. (No. 50532-2020).
참고문헌
- R.L. Moss, Critical review, with an optimistic outlook, on boron neutron capture therapy (BNCT), Appl. Radiat. Isot. 88 (2014) 2-11. https://doi.org/10.1016/j.apradiso.2013.11.109
- L. Kankaanranta, T. Seppala, H. Koivunoro, K. Saarilahti, T. Atula, J. Collan, E. Salli, M. Kortesniemi, J. Uusi-simola, P. Valimaaki, A. Makitie, M. Seppanen, H. Minn, H. Revitzer, M. Kouri, P. Kotiluoto, T. Seren, I. Auterinen, S. Savolainen, H. Joensuu, Boron neutron capture therapy in the treatment of locally recurred head and neck cancer: final analysis of a phase I/II trial, Int. J. Radiat. Oncol. Biol. Phys. 82 (2012) e67-e75. https://doi.org/10.1016/j.ijrobp.2010.09.057
- R.F. Barth, M.G.H. Vicente, O.K. Harling, W.S. Kiger III, K.J. Riley, P.J. Binns, F.M. Wagner, M. Suzuki, T. Aihara, I. Kato, S. Kawabata, Current status of boron neutron capture therapy of high grade gliomas and recurrent head and neck cancer, Radiat. Oncol. 7 (2012) 146-167. https://doi.org/10.1186/1748-717X-7-146
- S. Savolainen, M. Kortesniemi, M. Timonen, V. Reijonen, L. Kuusela, J. Uusi-Simola, E. Salli, H. Koivunoro, T. Seppala, N. Lonnroth, P. Valimaki, H. Hyvonen, P. Kotiluoto, T. Seren, A. Kuronen, S. Heikkinen, A. Kosunen, I. Auterinen, Boron neutron capture therapy (BNCT) in Finland: technological and physical prospects after 20 years of experiences, Phys. Med. 29 (2013) 233-248. https://doi.org/10.1016/j.ejmp.2012.04.008
- T. Kobayashi, Y. Sakurai, M. Ishikawa, A noninvasive dose estimation system for clinical BNCT based on PG-SPECT-Conceptual study and fundamental experiments using HPGe and CdTe semiconductor detectors, Med. Phys. 27 (2000) 2124-2132. https://doi.org/10.1118/1.1288243
- R. Seki, Y. Wakisaka, N. Morimoto, M. Takashina, M. Koizumi, H. Toki, M. Fukuda, Physics of epi-thermal boron neutron capture therapy (epi-thermal BNCT), Radiol. Phys. Technol. 10 (2017) 387-408. https://doi.org/10.1007/s12194-017-0430-5
- M. Manabe, F. Sato, I. Murata, Basic detection property of an array-type CdTe detector for BNCT-SEPCT - measurement and analysis of anti-coincidence events, Appl. Radiat. Isot. 118 (2016) 389-394. https://doi.org/10.1016/j.apradiso.2015.11.003
- B. Hales, T. Katabuchi, N. Hayashizaki, K. Terada, M. Igashira, T. Kobayashi, Feasibility study of SPECT system for online dosimetry imaging in boron neutron capture therapy, Appl. Radiat. Isot. 88 (2014) 167-170. https://doi.org/10.1016/j.apradiso.2013.11.135
- I. Murata, T. Mukai, S. Nakamura, H. Miyamaru, I. Kato, Development of a thick CdTe detector for BNCT-SPECT, Appl. Radiat. Isot. 69 (2011) 1706-1709. https://doi.org/10.1016/j.apradiso.2011.05.014
- P.M. Rosenschold, D. Minarik, C. Ostlund, M. Ljungberg, C. Ceberg, Prompt gamma tomography during BNCT-A feasibility study, J. Instrum. 1 (2006) p05003.
- A. Winkler, H. Koivunoro, S. Savolainen, Analysis of MCNP simulated gamma spectra of CdTe detectors for boron neutron capture therapy, Appl. Radiat. Isot. 124 (2017) 114-118. https://doi.org/10.1016/j.apradiso.2017.03.018
- I. Murata, T. Mukai, M. Ito, H. Miyamaru, S. Yoshida, Feasibility study on BNCTSPECT using a CdTe detector, J. Nucl. Sci. Technol. 1 (2011) 267-270.
- W.L. Duvall, L.B. Croft, E.S. Ginsberg, A.J. Einstein, K.A. Guma, T. George, M.J. Henzlova, Reduced isotope dose and imaging time with a high-efficiency CZT SPECT camera, J. Nucl. Cardiol. 18 (2011) 847-857. https://doi.org/10.1007/s12350-011-9379-7
- S. Fatemi, S. Altieri, S. Bortolussi, I. Postuma, G. Benassi, N. Zambelli, M. Bettelli, M. Zanichelli, A. Zappettini, N. Protti, Preliminary characterization of a CdZnTe photon detector for BNCT-SPECT, Nucl. Instrum. Methods A 903 (2018) 134-139. https://doi.org/10.1016/j.nima.2018.06.068
- D.M. Minsky, A.A. Valda, A.J. Kreiner, S. Green, C. Wojnecki, Z. Ghani, First tomographic image of neutron capture rate in a BNCT facility, Appl. Radiat. Isot. 69 (2011) 1858-1861. https://doi.org/10.1016/j.apradiso.2011.01.030
- N.J. Cherepy, P.R. Beck, S.A. Payne, E.L. Swanberg, B.M. Wihl, S.E. Fisher, S. Hunter, P.A. Thelin, C.J. Delzer, S. Shahbazi, A. Burger, K.S. Shah, R. Hawrami, L.A. Boatner, M. Momayezi, K. Stevens, M.H. Randles, D. Solodovnikov, History and current status of strontium iodide scintillators, Proc. SPIE 10392 (2017) 1-7.
- S. Yamamoto, J. Kataoka, T. Oshima, T. Ogata, T. Watabe, H. Ikeda, Y. Kanai, J. Hatazawa, Development of a high resolution gamma camera system using finely grooved GAGG scintillator, Nucl. Instrum. Methods Phys. Res., Sect. A 821 (2016) 28-33. https://doi.org/10.1016/j.nima.2016.03.060
- F.R. Schneider, K. Shimazoe, I. Somlai-Schweiger, S.I. Ziegler, A PET detector prototype based on digital SiPMs and GAGG scintillators, Phys. Med. Biol. 60 (2015) 1667-1679. https://doi.org/10.1088/0031-9155/60/4/1667
- N.J. Cherepy, B.W. Sturm, O.B. Drury, T.A. Hurst, S.A. Sheets, L.E. Ahle, C.K. Saw, M.A. Pearson, S.A. Payne, A. Burger, L.A. Boatner, J.O. Ramey, E.V. van Loef, J. Glodo, R. Hawrami, W.M. Higgins, K.S. Shah, W.W. Moses, SrI2 scintillator for gamma ray spectroscopy, Proc. SPIE 7449 (2009) 1-6.
- K. Nishimoto, Y. Yokota, S. Kurosawa, J. Pejchal, K. Kamada, V. Chani, A. Yoshikawa, Effects of La, Gd, or Lu co-doping on crystal growth and scintillation properties of Eu:SrI2 single crystals, J. Cryst. Growth 401 (2014) 484-488. https://doi.org/10.1016/j.jcrysgro.2014.02.022
- S. Jan, G. Santin, D. Strul, S. Staelens, K. Assie, D. Autret, S. Avner, R. Barbier, M. Bardies, P.M. Bloomfield, D. Brasse, V. Breton, P. Bruyndonckx, I. Buvat, A.F. Chatziioannou, Y. Choi, Y.H. Chung, C. Comtat, D. Donnarieix, L. Ferrer, S.J. Glick, C.J. Groiselle, D. Guez, P.-F. Honore, S. Kerhoas-Cavata, A.S. Kirov, V. Kohli, M. Koole, M. Krieguer, D.J. van der Laan, F. Lamare, G. Largeron, C. Lartizien, D. Lazaro, M.C. Maas, L. Maigne, F. Mayet, F. Melot, C. Merheb, E. Pennacchio, J. Perez, U. Pietrzyk, F.R. Rannou, M. Rey, D.R. Schaart, C.R. Schmidtlein, L. Simon, T.Y. Song, J.-M. Vieira, D. Visvikis, R. Van de Walle, E. Wieers, C. Morel, GATE: a simulation toolkit for PET and SPECT, Phys. Med. Biol. 49 (2004) 4543-4561. https://doi.org/10.1088/0031-9155/49/19/007
- M. Yoshino, K. Kamada, Y. Shoji, S. Kurosawa, Y. Yokota, Y. Ohashi, A. Yoshikawa, S. Yamamoto, Development of Eu:SrI2 scintillator array for gamma-ray imaging applications, IEEE Trans. Nucl. Sci. 64 (2017) 1647-1651. https://doi.org/10.1109/TNS.2017.2676769
- J. Iwanowska, L. Swiderski, T. Szczesniak, P. Sibczynski, M. Moszynski, M. Grodzicka, K. Kamada, K. Tsutsumi, Y. Usuki, T. Yanagida, A. Yoshikawa, Performance of cerium-doped Gd3Al2Ga3O12(GAGG:Ce) scintillator in gamma-ray spectrometry, Nucl. Instrum. Methods Phys. Res., Sect. A 712 (2013) 34-40. https://doi.org/10.1016/j.nima.2013.01.064
- T.E. Blue, J.C. Yanch, Accelerator-based epithermal neutron sources for boron neutron capture therapy of brain tumors, J. Neuro Oncol. 62 (2003) 19-31. https://doi.org/10.1023/A:1023247222043
- S.H. Park, C.Y. Han, S.Y. Kim, J.K. Kim, Use of the CT images for BNCT calculation: development of BNCT treatment planning system and its applications to dose calculation for voxel phantoms, Radiat. Protect. Dosim. 110 (2004) 661-667. https://doi.org/10.1093/rpd/nch235
- A. Rorer, Current Status of Neutron Capture Therapy, International Atomic Energy Agency, 2001, pp. 6-8. IAEA-TECDOC-1223.
- A.L. Weinmann, C.B. Hruska, M.K. O'Connor, Design of optimal collimator for dedicated molecular breast imaging systems, Med. Phys. 36 (2009) 845-856. https://doi.org/10.1118/1.3077119
- M. F Smith, S. Majewski, A.G. Weisenberger, Optimizing pinhole and parallel hole collimation for scintimammography with compact pixelated detectors, IEEE Trans. Nucl. Sci. 50 (2003) 321-326. https://doi.org/10.1109/TNS.2003.812436
- S.R. Cherry, J.A. Sorenson, M.E. Phelps, Image Quality in Nuclear Medicine, Physics in Nuclear Medicine, Saunders, Philadelphia, 2012, pp. 243-249.