References
- Shin. H. S., Hong. J. K., Kim. J. S., Chung. Y. K., Jhung. M. J., Chung. H. D., and Choi. Y. H., 2011, "Development of Regulation on the Integrated Material Aging Management for Nuclear Facilities," Trans. of the KPVP, Vol. 7, No. 4, pp. 12-18. doi:https://doi.org/10.20466/KPVP.2011.7.4.012
- Chung. H. S., 2010, "A review of CANDU feeder wall thinning," Nucl. Eng. Technol., Vol. 42, No. 5, pp. 568-575. doi:https://doi.org/10.5516/NET.2010.42.5.568
- Lee. S. H., Lee. Y. S., Kim. H. D., Lee. K. S., and Hwang. K. M., 2015, "Review on the Integrity Evaluation and Maintenance of Wall-Thinned Pipe," Trans. of the KPVP, Vol. 11, No. 2, pp. 51-60. doi:https://doi.org/10.20466/KPVP.2015.11.2.051
- KINS, 2005, "Development of inspection procedure for carbon steel pipe wall-thinning management program," Korea Institute of Nucleare Safety, Daejeon, KINS/RR-350.
- Kim. J. W., Park. C. Y., and Kim. T. S., 2003, "Effect of Internal Wall Thinning Defect on the Burst Pressure of Elbow," Spring meeting of the KNS, Gyeongju, May 29-30.
- Kim. Y. J., and Oh. C. S., 2006, "Closed-form plastic collapse loads of pipe bends under combined pressure and in-plane bending," Eng. Fract. Mech., Vol. 73, Issue 11, pp. 1437-1454. doi:https://doi.org/10.1016/j.engfracmech.2006.02.001
- An. J. H., Kim. J. H., Hong. S. P., Park. C. Y., and Kim. Y. J., 2007, "Plastic Limit Loads of 90° Elbows with Local Wall Thinning using Small Strain FE Limit Analyses (I)-Internal Pressure," Transactions of the Korean Society of Mechanical Engineers A, Vol. 31, No. 5, pp. 586-593. doi:https://doi.org/10.3795/KSME-A.2007.31.5.586
- Kim. J. H., An. J. H., Hong. S. P., Park. C. Y., and Kim. Y. J., 2007, "Plastic Limit Loads of 90° Elbows with Local Wall-Thinning Using Small Strain FE Limit Analyses (II)-Bending Moment," Transactions of the Korean Society of Mechanical Engineers A, Vol. 31, No. 4, pp. 496-505. doi:https://doi.org/10.3795/KSME-A.2007.31.4.496
- Bae. K. D., Je. J. H., Kim. J. S., and Kim. Y. J., 2012, "Limit loads for circular wall-Thinned feeder pipes considering bend angle," Transactions of the Korean Society of Mechanical Engineers A, Vol. 36, No. 3, pp. 313-318. doi:https://doi.org/10.3795/KSME-A.2012.36.3.313
- KAERI, 2002, "Diagnostic technology for degradation of feeder pipes and fuel channels in CANDU reactor," Korea Atomic Energy Research Institute, Daejeon, KAERI/RR-2226/2001
- Kim. Y. J., Kim. N. H., Oh. C. Y., and Oh. C. S., 2008, "A method to estimate plastic loads for elbows with non-uniform thicknesses," Fatigue Fract. Eng. M., Vol. 31, Issue 9, pp. 822-837. doi:https://doi.org/10.1111/j.1460-2695.2008.01268.x
- Michael. T. C., Veerappan. A. R., and Shanmugam. S., 2012, "Effect of ovality and variable wall thickness on collapse loads in pipe bends subjected to in-plane bending closing moment," Eng. Fract. Mech., Vol. 79, pp. 138-148. doi:https://doi.org/10.1016/j.engfracmech.2011.10.009
- KINS, 2021, Internal communication.
- Dassault Systemes, 2020, "Abaqus Analysis User's Guide Ver. 2020", Velizy-Villacoublay.
- ASME B&PVC Sec.III, Subsection NB, NB-3641.1, 2009, "Rules for Construction of Nuclear Facility Components," American Society of Mechanical Engineers, NY.