Abstract

The management and installation methods of pressure gauges in water supply pipeline are not efficiently regulated and their installations are different in each site. In this paper, various domestic and overseas documents are examined about the pressure gauge. In order to improve the efficiency of operation management such as pipeline network and pump operation, water pressure needs to be measured as accurate as possible, by which decision making for optimal pipe network can be achieved. To get the goal, the installation of pressure gauge should be reviewed about where and how to install. In this study, an optimal horizontal distance test is conducted, in which pressure value variation is monitored and analyzed according to up and down stream distances and valve flow control, and a optimal vertical position test is also analyzed by installing the pressure gauges vertically from the up(180°) to the bottom (0°) of the pipeline.

먹는 물을 생산하여 공급하는 상수도 관로에 있어서 압력계에 대한 설치와 관리 방안이 미비함에 따라 압력데이터 신뢰성의 확보 및 운영관리의 어려움을 겪고 있는 실정이다. 관망 및 펌프 등 운영관리 효율화 및 SWM(Smart Water Management)을 구현하기 위해서는 하부 계측 센서의 정확한 데이터 취득을 통하여 의사결정이 이루어져야 한다. 따라서, 본 연구에서는 게이트 밸브와 버터플라이 밸브를 중심으로 관로의 직경(D)을 기준으로 전단 -3D에서부터 후단 7D까지 압력계를 설치하여 밸브의 개도율을 조절하며 데이터를 취득하는 직관 거리 시험을 실시하였으며, 관로에 수직으로 상단(180°)부터 하단(0°)까지 45° 각도 간격으로 압력계를 설치한 후 수직 위치 시험을 실시하였으며, 이 결과들을 바탕으로 압력계의 최적 위치선정 방안을 제시하고자 한다.

Keywords

References

  1. Ministry of Environment, 2017 Constant water statistics, pp. 17-18, 2017.
  2. Ministry of Environment, Description of the 2018 Water Supply Standards revised research, Jan. 2019.
  3. Korea Occupational Safety & Health Agency, Technical specification for the installation of pressure measuring devices, pp. 1-6, Dec. 2017.
  4. Korea Occupational Safety & Health Agency, Technical specification for application of pressure system, pp. 1-9, Jun. 2017.
  5. K. M. Choi, H. H. Lee, G. W. Shin, and S. T. Hong, "Analysis of Elastic Wave Based Leakage Detection Technology Using Accel," Journal of the Korea Institute of Information and Communication Engineering, vol. 24, no. 9, pp. 1121-1130, Sept. 2020.
  6. Korea Occupational Safety and Health Agency, Technical Guidelines for the Installation of Pressure Measuring Devices, pp. 1-6, 2011.
  7. Korea Association of Standards & Testing Organizations, Pressure precision Measurement Technology, pp. 39-96, 2017.
  8. K-water, Criteria for installing and managing flow meters, pp. 1-35, 2015.
  9. K-water, Standard for installation of valves and instrumentation facilities on a conduit, pp. 1-8, 2018.
  10. Y. T. Jung, Fundamentals of Pressure Sensor, Flow Sensor and Level Sensor, Gonggambooks, 2015.
  11. KS B 2101, How to Test the Capacity Factor of Valves, pp. 1-2, 2003.
  12. Y. J. Heo, H. H. Lee, and S. T. Hong, "Calibration System and Data Analysis for improving the Reliability of Pressure Sensor," in Proceeding of Symposium of the Korean Institute of communications and Information Sciences, Jeju, pp. 806-807, 2017.