DOI QR코드

DOI QR Code

A Study for Durability Test of Dynamic Power Cable under Marine Operating Environment Condition

동적 파워 케이블의 해양운용환경 내구성 검증시험에 관한 연구

  • Shim, Chunsik (Dep. of Naval Architecture & Ocean Engineering, Mokpo National University) ;
  • Kim, Chulmin (LS Cable & System, Platform Technology Development Group) ;
  • Rho, Yuho (LS Cable & System, Platform Technology Development Group) ;
  • Lee, Jaebok (LS Cable & System, Platform Technology Development Group) ;
  • Chae, Kwangsu (LS Cable & System, Platform Technology Development Group) ;
  • Song, Hacheol (Dep. of Naval Architecture & Ocean Engineering, Mokpo National University) ;
  • Kim, Hokyeong (Dep. of Naval Architecture & Ocean Engineering, Mokpo National University) ;
  • Bae, Chulmin (Dep. of Naval Architecture & Ocean Engineering, Mokpo National University) ;
  • Wi, Sungkuk (SURF R&D Center, Mokpo National University) ;
  • Im, Kichen (SURF R&D Center, Mokpo National University)
  • 심천식 (목포대학교 조선해양공학과) ;
  • 김철민 (LS전선 기술개발본부 기반기술연구소) ;
  • 노유호 (LS전선 기술개발본부 기반기술연구소) ;
  • 이재복 (LS전선 기술개발본부 기반기술연구소) ;
  • 채광수 (LS전선 기술개발본부 기반기술연구소) ;
  • 송하철 (목포대학교 조선해양공학과) ;
  • 김호경 (목포대학교 조선해양공학과) ;
  • 배철민 (목포대학교 조선해양공학과) ;
  • 위성국 (목포대학교 해양케이블시험연구센터) ;
  • 임기천 (목포대학교 해양케이블시험연구센터)
  • Received : 2019.12.28
  • Accepted : 2020.11.13
  • Published : 2021.02.20

Abstract

In the production power transmitting of a floating production system like a wind offshore floating, the power cable should be connected from the surface system into the subsea system. The connection between the surface and the subsea system will make the power cable get a dynamic load like current and wave forces. Based on this condition, a dynamic power cable is required to endure external physical force and vibration in the long-term condition. It needs more requirements than static power cable for mechanical fatigue properties to prevent failures during operations in marine environments where the external and internal loads work continuously. As a process to verify, the durability test of dynamic power cables under the marine operation environment condition was carried out by using domestic technology development.

Keywords

References

  1. API 17E 2nd, 5th edition. 2017. Specification for Subsea Umbilicals.
  2. Dai, T., Saevik, S., & Ye, N., 2020. Experimental and numerical studies on dynamic stress and curvature in steel tube umbilicals. Marine Structures. 2020, 72, 102724. https://doi.org/10.1016/j.marstruc.2020.102724
  3. DNVGL Standard 0119, 2018. Floating wind turbine structure.
  4. Hobbs, R.E., & Raoof, M., 1996. Behaviour of Cables under Dynamic or Repeated Loading. Journal of Constructional Steel Research. 39(1), pp.31-50. https://doi.org/10.1016/0143-974X(96)00028-4
  5. Karlsen, S., 2010. Fatigue of Copper Conductors for Dynamic Subsea Power Cables, In: Nexans, International Conference on Ocean, Offshore and Arctic Engineering. Shanghai, 6-11 June 2010, pp.275-281.
  6. Kumar, K., & Botsis, J., 2001. Contact Stresses in Multilayered Strands under Tension and Torsion. ASME Journal of Applied Mechanics. 68(3), pp.432-440. https://doi.org/10.1115/1.1355777
  7. Kuznecovs, A. et al., 2019. A methodology for design and fatigue analysis of power cables for wave energy converters. International Journal of Fatigue. 122, pp.61-71. https://doi.org/10.1016/j.ijfatigue.2019.01.011
  8. IEC, 60228, 2014. Conductors of Insulated Cables.
  9. IEC, 60502-2, 2014. Power Cables with Extruded Insulation and Their Accessories for Rated Voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV).
  10. Petrobras specification I-ET-3500.00-1500-291-PAZ-002 REV.B, Umbilical for Subsea Applications, "Qualification Tests for Umbilicals".