DOI QR코드

DOI QR Code

Temperature Compensation of Nondispersive Infrared Gas Senor: Infrared Light Absorbance

비분산 적외선 가스 센서 온도 보상법: 적외선 흡수도

  • Yi, SeungHwan (College of Convergence Technology, Korea National University of Transportation)
  • 이승환 (한국교통대학교 융합기술대학 기계공학전공)
  • Received : 2021.01.10
  • Accepted : 2021.01.25
  • Published : 2021.01.31

Abstract

The motivation of this paper is to easily analyze the properties of nondispersive infrared gas sensor that has more than two different optical path length and to suggest the criterion and definition of infrared light absorbance in order to minimize the measurement errors. With the output voltage ratios and the normalized derivatives of infrared ray (IR) absorbance, when the normalized derivatives of IR absorbance decreases from 0.28 to 0.10, the lower and higher limits of errors were decreased from -5.62% and 2.39% to -4.27% and 2.78%. When the normalized derivatives of IR absorbance were 0.10, the output voltage could be partitioned into two regions with one exponential equation and the temperature compensation error was less than 5%.

Keywords

References

  1. https://www.sensirion.com/kr/environmental-sensors/carbon-dioxide-sensors/carbon-dioxide-sensors-co2/(retrieved Dec. 29, 2020).
  2. http://allsensing.com/product/list.html?cate_no=62/(retrieved Dec. 29, 2020).
  3. J. S. Park and S. H. Yi, "Temperature compensation of NDIR CO gas sensor implemented with ASIC chip", KIGAS, Vol. 11, No. 1, pp. 40-45, 2007.
  4. S. H. Yi, "Temperature compensation methods of nondispersive infrared CO gas sensor with dual ellipsoidal optical waveguide", Sensor Mater., Vol. 29, No.3, pp. 243-252, 2017. https://doi.org/10.18494/SAM.2017.1439
  5. S. H. Yi, Y.H. Park, and J. K. Lee, "Temperature dependency of nondispersive infrared carbon dioxide gas sensor by using White-cell structure", J. Sens. Sci. Technol., Vol. 25, No. 5, pp. 377-381, 2016. https://doi.org/10.5369/JSST.2016.25.5.377
  6. T. A. Vincent and J. W. Gardner, "A low cost MEMS based NDIR system for the monitoring of carbon dioxide in breath analysis at ppm levels", Sens. Actuators B-Chem,, Vol. 236, pp. 954-964, 2016. https://doi.org/10.1016/j.snb.2016.04.016
  7. S. H. Yi, "Temperature dependency of non-dispersive infrared carbon dioxide gas sensor by using infrared sensor for compensation", J. Sens. Sci. Technol., Vol.25, No. 2, pp. 124-130, 2016. https://doi.org/10.5369/JSST.2016.25.2.124
  8. J. H. Kim and S. H. Yi, "Effects of temperature and humidity on NDIR CO2 gas sensor", J. Sens. Sci. Technol., Vol. 26, No. 3, pp.179-185, 2017. https://doi.org/10.5369/JSST.2017.26.3.179
  9. S. H. Yi, "Infrared light absorbance: a new method for temperature compensation in nondispersive infrared CO2 gas sensor", J. Sens. Sci. Technol., Vol 29, No. 3, pp. 303-311, 2020. https://doi.org/10.46670/JSST.2020.29.5.303
  10. L. Jun, T. Quilin, Z. Wendong, X. Chenyang, G. Tao, and X. Jinjun, "Miniature low power IR monitor for methane detection", Measurement, Vol. 44, pp. 823-831, 2011. https://doi.org/10.1016/j.measurement.2011.01.021
  11. H. G. Park and S. H. Yi, "Analysis of output voltage properties of non-dispersive infrared gas sensors according to ambient temperature", J. Sens. Sci. Technol., Vol. 27, No.3, pp. 294-299, 2018.
  12. W. B. De More and M. Patapoff, "Temperature and pressure dependence of CO extinction coefficient", J. Geophys. Res., Vol. 77, No. 31, pp. 6291-6293, 1972. https://doi.org/10.1029/JA077i031p06291