Abstract

Tightness performance that blocks compartments is important for surface ships to achieve superior mission performance and survivability in combat environments. To meet the above requirements, airtightness of the structural elements and the appropriate strength to specific areas are checked during a test run after ship construction. In particular, air tests of compartments adjacent to the water surface are performed. In an air test, air is injected into the compartment up to the test pressure of the test memo. The pressure drop value is checked after 10 minutes to determine if the requirements of the corresponding area are satisfied. In summer, however, when the influence of the outside temperature is large, a phenomenon in which the internal pressure increases during the air test was identified. This phenomenon reduces the reliability of the test result. Therefore, a system was designed to compensate for temperature changes in the compartments through this study. The developed system calculates the amount of pressure change caused by a temperature change in the compartment and outputs a correction value. The pressure change was calculated using the ideal gas equation, reflecting the maintenance, increase, and decrease in temperature during the test process. A comparison of the calculated pressure correction value with the database of NIST REFPROP revealed a difference of 0.126% to a maximum of 0.253%.

수상함이 전투 환경에서 우수한 임무수행능력과 생존성을 구현하기 위해서는 구획을 차단하는 수밀/기밀 성능이 중요하다. 위와 같은 요구사항을 충족을 위해 함정 건조 후 시운전에서 구조요소(격실 및 탱크)에 대한 밀폐성과 특정부위에 대한 강도의 적합성을 검사하며, 특히 수선에 인접한 격실들의 격실기밀시험(Air test)을 수행한다. 격실기밀시험은 대상 격실에 공기를 주입하여 시운전 평가서 상의 요구압력까지 압을 적용하고, 일정 시간동안 압력강하 값을 확인하여 해당 구역의 요구조건 충족여부를 판단한다. 검사 기준은 10분 동안 감소된 압력이 시운전 평가서의 압력강하 허용치 이내이어야 한다. 하지만 외기온도의 영향이 큰 여름철에 격실기밀시험 진행 간 유입되는 열이 내부 공기의 온도를 상승시키고, 이로 인해 공기가 팽창하여 격실 내 압력이 증가하는 현상이 식별되었다. 이러한 현상은 격실기밀시험에서 최종 압력강하 값을 정확히 판단할 수 없게 하고 평가결과에 대한 신뢰성을 결여시킬 수 있다. 본 연구를 통해 격실 내 온도변화 영향을 보정하기 위한 시스템을 고안하였다. 개발된 시스템은 격실 내 온도변화에 의한 압력 변화량을 계산하여 보정값을 출력한다. 이상기체 방정식을 통해 압력변화량을 계산하며, 격실기밀시험 간 온도유지 및 증가/감소를 반영할 수 있도록 개발되었다. 계산된 압력 보정값을 NIST REFPROP의 데이터 베이스와 비교하였을 때, 최소 0.126 %에서 최대 0.253 %의 차이를 보였다.

Keywords

References

  1. J. H. Kim, A Study on Structural Vulnerability Countermeasure Design and Analysis Techniques for Survivability Enhancement of Naval Ship, Ph.D dissertation, Korea Maritime & Ocean University Graduate School, Pusan, Korea, pp.1-2
  2. S. K. Park, J.H. Choi, J.H. Kim, and G.Y. Gong, "Structural Integrity Evaluation of Sliding Type Watertight Door for Ship", The Korea Society for Naval Science & Technology, pp.008-010, March. 2019, DOI: http://doi.org/10.31818/JKNST.2019.03.2.1.8
  3. S. M. Choi, D. K. Park, Y. K. Beak, "A Study on the Reliability Improvement of Compartment Leak Test in Surface Vessels", Journal of the Korea Academia-Industrial cooperation Society, Vol.21, No.4, pp.546-551, 2020 DOI: http://dx.doi.org/10.5762/KAIS.2020.21.4.546
  4. U.S Maritime Transportation Research Institute, Improved Tank Testing Methods, Department of Commerce Maritime Administration, U.S, pp.1-140
  5. R.O.K. Navy, Guideline for Watertight/Airtight Testing of Compartments and Tanks Survey, Criteria for Naval Ship Design & Construction, R.O.K. Navy, Korea, 1-9p.
  6. D. E. Jung, C. Lee, S. L. Do, "Analysis of the Window Glazing Heat Transfer of Installation of an External Shading", Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol.32, No.6, pp.278-287, 2020 DOI: http://dx.doi.org/10.6110/KFACR.2020.32.6.278
  7. J. H. Song, J.M. Oh, J.H. Lim, and S.Y. Song, "Energy Performance Evaluation of Metal-Exterior Curtain Wall Panel Systems", Spring Conference of Architectural Institute of Korea, Architectural Institute of Korea ,Seoul, Korea, Vol.35, No.1, pp.247-248, April, 2015.
  8. G. Lee, "Recent Trends in Air-Conditioning Load Calculation Method", The Society of Air-Conditioning and Refrigeration Engineering of Korea, Vol.3, No.2, pp.103-104, 1974
  9. National Institute of Standards and Technology, Reference Fluid Thermodynamic and Transport Properties Database(REFPROP) [Internet], National Institute of Standards and Technology, c2009 [cited 2009 April 22], Available From: https://www.nist.gov/programs-projects/reference-fluid-thermodynamic-and-transport-properties-database-refprop (accessed August 31, 2020)