References
- Ali Z, Baker SR, Shahrbaf S, Martin N, Vettore MV. Oral health-related quality of life after prosthodontic treatment for patients with partial edentulism: a systematic review and meta-analysis. J Prosthet Dent 2019; 121:59-68. https://doi.org/10.1016/j.prosdent.2018.03.003
- Sargozaie N, Moeintaghavi A, Shojaie H. Comparing the quality of life of patients requesting dental implants before and after implant. Open Dent J 2017;11: 485-91. https://doi.org/10.2174/1874210601711010485
- Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent 1999;81:537-52. https://doi.org/10.1016/S0022-3913(99)70208-8
- Lee HW, Alkumru H, Ganss B, Lai JY, Ramp LC, Liu PR. The effect of contamination of implant screws on reverse torque. Int J Oral Maxillofac Implants. 2015;30: 1054-60. https://doi.org/10.11607/jomi.3976
- Tzenakis GK, Nagy WW, Fournelle RA, Dhuru VB. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent 2002;88:183-91. https://doi.org/10.1067/mpr.2002.127604
- Tan KB, Nicholls JI. The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint. Int J Oral Maxillofac Implants 2002; 17:175-83.
- Guda T, Ross TA, Lang LA, Millwater HR. Probabilistic analysis of preload in the abutment screw of a dental implant complex. J Prosthet Dent 2008;100:183-93. https://doi.org/10.1016/S0022-3913(08)60177-8
- Jorn D, Kohorst P, Besdo S, Rucker M, Stiesch M, Borchers L. Influence of lubricant on screw preload and stresses in a finite element model for a dental implant. J Prosthet Dent 2014;112:340-8. https://doi.org/10.1016/j.prosdent.2013.10.016
- Guzaitis KL, Knoernschild KL, Viana MA. Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology. J Prosthet Dent 2011;106:159-69. https://doi.org/10.1016/S0022-3913(11)60115-7
- Sahin C, Ayyildiz S. Correlation between microleakage and screw loosening at implant-abutment connection. J Adv Prosthodont 2014;6:35-8. https://doi.org/10.4047/jap.2014.6.1.35
- Cardoso M, Torres MF, Lourenço EJ, de Moraes Telles D, Rodrigues RC, Ribeiro RF. Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study. Clin Oral Implants Res 2012; 23:475-80. https://doi.org/10.1111/j.1600-0501.2011.02165.x
- Al Rafee MA, Nagy WW, Fournelle RA, Dhuru VB, Tzenakis GK, Pechous CE. The effect of repeated torque on the ultimate tensile strength of slotted gold prosthetic screws. J Prosthet Dent 2002;88:176-82. https://doi.org/10.1067/mpr.2002.127652
- Duarte AR, Neto JP, Souza JC, Bonachela WC. Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution. J Prosthodont 2013;22:275-81. https://doi.org/10.1111/j.1532-849X.2012.00941.x
- Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent 1999;81: 159-66. https://doi.org/10.1016/S0022-3913(99)70243-X
- Ghanbarzadeh J, Dashti H, Abasi M, Nakhaei M. Torque removal evaluation of one-piece and twopiece abutment screws under dry and wet conditions. J Mashad Dent Sch 2015;39:89-98.
- Gumus HO, Zortuk M, Albayrak H, Dincel M, Kocaagaoglu HH, Kilinc HI. Effect of fluid contamination on reverse torque values in bone-level implants. Implant Dent 2014;23:582-7.
- Koosha S, Toraji S, Mostafavi AS. Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections. J Prosthet Dent 2020;123:618-21. https://doi.org/10.1016/j.prosdent.2019.05.001
- Micarelli C, Canullo L, Baldissara P, Clementini M. Implant abutment screw reverse torque values before and after plasma cleaning. Int J Prosthodont 2013;26: 331-3. https://doi.org/10.11607/ijp.3396
- Nigro F, Sendyk CL, Francischone CE Jr, Francischone CE. Removal torque of zirconia abutment screws under dry and wet conditions. Braz Dent J 2010;21:225-8. https://doi.org/10.1590/S0103-64402010000300009
- Jalali H, Moslemion N, Nokar S. Effect of blood and saliva contamination of the implant-abutment interface on the amount of preload. Dentistry Adv Res 2018;3:1-7.
- Kozlovsky A, Artzi Z, Moses O, Kamin-Belsky N, Greenstein RB. Interaction of chlorhexidine with smooth and rough types of titanium surfaces. J Periodontol 2006;77:1194-200. https://doi.org/10.1902/jop.2006.050401
- Zavanelli RA, Henriques GEP, Ferreira I, de Almeida Rollo JM. Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments. J Prosthet Dent 2000;84:274-9. https://doi.org/10.1067/mpr.2000.108758
- Souza J, Barbosa S, Ariza E, Celis J-P, Rocha L. Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides. Wear 2012; 292-3:82-8.