DOI QR코드

DOI QR Code

Separation of Light Rare-Earth Elements Using Gas-Pressurized Extraction Chromatography

  • Kim, Namuk (Korea Atomic Energy Research Institute(KAERI)) ;
  • Park, Jai Il (Korea Atomic Energy Research Institute(KAERI)) ;
  • Um, Wooyong (Division of Advanced Nuclear Engineering(DANE), Pohang University of Science and Technology(Postech)) ;
  • Kim, Jihye (Korea Atomic Energy Research Institute(KAERI))
  • Received : 2021.11.24
  • Accepted : 2021.12.07
  • Published : 2021.12.31

Abstract

A new method for chemical separation of light rare-earth elements (LREEs) using gas-pressurized extraction chromatography (GPEC) is described. GPEC is a microscale column chromatography system that features a constant flow of solvents, which is created by pressurized nitrogen gas. The separation column with a Teflon tubing was packed with LN resin. The proposed GPEC method facilitates production of lesser chemical wastes and faster separation owing to the use of low solvent volume compared to traditional column chromatography. We evaluated the separation of Ba, La, Ce, and Nd using various elution solvents. The column reproducibility of the proposed GPEC system ranged from 2.4% to 4.9% with RSDs of recoveries, and the column-to-column reproducibility ranged from 3.1% to 6.3% with RSDs of recoveries. The proposed technique is robust, and it can be useful for the fast separation of LREEs.

Keywords

Introduction

Rare-earth elements (REEs) are a series of chemical elements in period 6 of the periodic table, and they are known as lanthanides; they also include scandium and yttrium. The outer electrons in lanthanide REEs have common electron configuration of 4f0-145d0, 16s2 except Sc (3d14s2) and Y (4d15s2) and they are generally trivalent, M3+. These elements are characterized by the successive addition of an electron to the seven 4f orbitals, meaning that they all have similar electron configurations, atomic radii, and chemical properties, which makes their separation very challenging.1 This study focused on light REEs (LREEs) and barium, because of their increasing needs in various industries, such as age dating for geology, nuclear safeguards, and burnup measurement of nuclear fuel.2-6 LREEs include lanthanum, cerium, praseodymium, neodymium, promethium, and samarium with atomic numbers from 57 to 62.7 The analysis of LREEs of fission products in spent nuclear fuel is challenging due to isobaric interferences prior to mass spectrometry (e.g., 138La versus 138Ce, 142Nd versus 142Ce, and 150Nd versus 150Sm), 8-10 and thus, chemical separation processes are necessary for isolating individual LREEs and achieving good quantitative results.

Typically, chromatographic techniques have been applied to separate LREEs.11 Ion exchange chromatographic method has been commonly applied to analyze REEs.11 In the late 1950s, separation of lanthanum and thorium using anion exchange resin was published.12 Many other studies using anion exchange or cationic exchange resin have been performed, such as separation resolution studies using various concentrations of cross-linking agents in 1970s13 and distribution coefficients using various concentrations of different eluents.14 Based on the results until 1980s, samarium and neodymium were completely separated, but considering the flow rate (1.0 mL/min) and the amount of elute (~1L) for whole separation, one cycle required at least 16 h.15 Thus, though the ion exchange chromatographic method provides high separation resolution, it requires extremely long analysis time and wastes large amounts of eluents.

After the 1990s, research on LREE separation has been more focused on reducing analysis time and increasing resolution. Based on the study of chemical separation using 2-ethylhexylphosphoric acid (HDEHP) by Horwitz in 1975, 16 the resin for separation of LREE was commercialized as LN resin by Eichrom Technologies. Recently, this HDEHP- based LN resin has been utilized in many other studies, such as the separation of 177Lu from neutron irradiated 176Yb, 17 the analysis of 143Nd/144Nd in geological samples, 18 and sequential separation of LREE in silicate rocks, 19 which allows minimized experimental labor and analysis time. The analysis time of LREE using column chromatography method has decreased considerably from ~16 h15 (calculated with the volume of eluents and the flow rate) to 1.5 h.20 In particular, for analyses of radioactive samples, reducing the volume of liquid radioactive waste and total analysis time are essential for protecting the environment from hazardous radioactive waste and radiation dose to which researchers are exposed.21

LREEs as fission products from irradiated nuclear fuels are used for burnup determination.22 Burnup of irradiated nuclear fuels is defined as the energy produced per total mass of fuel, and it is determined by measuring the content of burnup monitor atoms and the fractional fission yield.23 Commonly, lanthanum, cerium, and neodymium have been utilized as burnup monitor atoms among LREEs.24 Thus, the chemical analyses of lanthanum, cerium, and neodymium are essential for spent fuel burnup determination.24

In this study, we evaluate the separation of LREEs using gas-pressurized extraction chromatography (GPEC). This technique is advantageous as it helps reduce the total volume of eluents for decreasing chemical or radioactive waste and the analysis time for efficient analysis. The GPEC system also provides a constant flow rate because of use of pressurized-nitrogen gas via the column.25-27 It ensures good reproducibility of the results compared to the traditional column chromatographic method that uses gravity. Herein, we investigate the effect of eluent type, acid concentration of eluent, and resin size to identify the optimal separation conditions for barium, lanthanum, cerium, and neodymium using the GPEC system. We also measure column reproducibility and column-to-column reproducibility with the recoveries from the four elements. The proposed GPEC system used as a separation technique prior to ICP-MS can overcome isobaric interferences. When mass spectrometry is used alone, it is very difficult to analyze various LREE radioactive isotopes, such as nuclear fission products including 139La-140La, 140Ba, 140Ce-144Ce, and 143Nd- 150Nd, among different LREEs.28 To develop a GPEC method, we applied the natural isotopes of LREEs (139La, 140Ce, and 144Nd) and barium (138Ba) instead of radioactive isotopes for the preliminary test; as a result, unnecessary radioactive waste was reduced.

Experimental

Reagents and materials

Barium (ICP-04N-1), lanthanum (ICP-28N-1), cerium (ICP-11N-1), and neodymium (ICP-36N-1) were purchased from AccuStandard (1000μg/mL each, New Haven, CT, USA). Ultrapure nitric acid was obtained from Merck (Suprapur 65%, St. Louis, MO, USA). Ultrapure-grade of hydrochloric acid was from Seastar chemicals (Sidney, BC, Canada). Deionized water (18 MΩ) was produced using a Milli-Q water system (Millipore, Burlington, MA, USA).

GPEC system and operation

All tubing used for the GPEC system was made of transparent Teflon to help easily observe the movement of the colorless chemical stream during the experiment. Teflon tubing (1/16" OD × 0.03" ID, VICI, Houston, TX, USA) was used for the analytical column (25 cm length). Two LN resins (Eichrom Technologies, Darien, IL, USA) with different resin particle sizes (50-100 μm (LN-B50-S) and 100-150μm (LN-B50-A)) were used for the analytical column. The column was packed by a syringe using 0.2 mg resin and 1mL of water. A peristaltic pump was used to inject the washing solvent, sample, and eluent by sucking from the sample vial to the sample loop, as shown in Figure 1. First, with a sample loop of defined volume (270μL), the washing solvent was filled into the sample loop and excess was discarded. After injecting the washing solvent, nitrogen gas was supplied by a valve at a flow rate of 67.5μL/min. Thereafter, the washing solvent was eluted out through the analytical column. Using the same procedure, the column was preconditioned by rinsing three times with water and once with 0.05M HCl. Between analyses, the column was rinsed with 0.75 M HCl, water, and 0.05 M HCl, sequentially. Thereafter, sample injection (one time) and eluent injections (repeat ten times) were successively collected (270μL-fractionations). Sample mixtures of the three LREEs (La, Ce, and Nd) and barium at 10μg/mL were dissolved in 0.05 M HCl. Eluents were evaluated with 0.1-0.3 M HCl and 0.5-1.0 M HNO3 with 100-150μm sized resins. Elution solvent of 0.25 M HCl was applied with 50-100μm sized resins to measure column reproducibility and column-to-column reproducibility with the recoveries. Figure 1 illustrates the GPEC system.

E1MPSV_2021_v12n4_186_f0001.png 이미지

Figure 1. GPEC system.

Precision experiment

Column reproducibility were the RSDs of the recoveries of LREEs and barium (five consecutive runs). Column-to- column reproducibility were the RSDs of the recoveries of LREEs and barium (five consecutive runs on each column) made on two columns packed with the same packing material. Sample mixtures of the three LREEs (La, Ce, and Nd) and barium at 10 μg/mL were dissolved in 0.05 M HCl. Gradient elution was applied using 0.25 M HCl and water as the eluent with a 50-100 μm-sized resin as Figure 4.

E1MPSV_2021_v12n4_186_f0004.png 이미지

Figure 4. Separation of LREEs and barium by GPEC with a 50- 100 μm sized resin and using 0.25 M HCl and water as eluent. Other conditions are presented in the experimental section.

Inductively coupled plasma-mass spectrometry (ICP-MS)

The performance of GPEC with collected fractions was measured using ICP-MS (SPECTRO MS, Kleve, Germany) equipped with a cyclonic spray chamber (Labkings, Hilversum, Netherlands) and a seaspray U-series nebulizer (Labkings, Hilversum, Netherlands). The samples were prepared by dilution to 5mL with 1% nitric acid. Calibration solutions were prepared with 1000 μg/mL single element standards and were in the range 1–20ng/mL. The operating conditions for ICP-MS are listed in Table 1.

Table 1. Operating conditions for ICP-MS.

E1MPSV_2021_v12n4_186_t0001.png 이미지

Results and Discussion

LN resin contains acidic akylphosphorus-based extractants, such as (2-ethylhexyl)phosphoric acid (HDEHP), on an inert polymeric support. Trivalent cations of LREEs (M3+) form binary or ternary complexes with HEDHP, as shown in Figure 2. As the pH of solution decreases, the equilibrium in Figure 2 shifts from (a) to (b) and from (b) to (c) under acidic aqueous conditions. Binding of LREEs on the column from low-acidity aqueous phases proceeds primarily through the cation exchange mechanism presented in Figure 2 (a).29

E1MPSV_2021_v12n4_186_f0002.png 이미지

Figure 2. Interaction mechanism of LREEs by LN resin.

As the P-OH groups become protonated at higher acid concentrations, less LREEs are retained on the column. At the highest acidities, LREEs become eluted. Based on this mechanism, 0.05 M HCl was used as a sample matrix and the elution solvent was applied at a higher concentrations (0.1–0.3 M HCl) than the sample matrix.

Separation of LREEs by GPEC depending on eluents

Different types and concentrations of eluents were investigated for the separation of three LREEs and barium by isocractic elution. First, three eluents, namely, nitric acid, hydrochloric acid dissolved in water, and hydrochloric acid dissolved in methanol were evaluated with 100-150μm sized resins. When nitric acid was used as the eluent with concentrations between 0.5 and 1 M, four elements were co-eluted within 3 fraction volumes (3×270μL). According to Ostapenko et al., 0.1 M-0.5 M HNO3 was the optimal condition for the separation of REEs using LN resin.29 Therefore, low concentration of nitric acid is effective for the separation of LREEs. When hydrochloric acid-methanol mixtures (10% and 30% methanol (0.2M HCl/MeOH, v/v)) were applied to separate the three LREEs and barium, the four elements were not detected within 20-fraction volumes (< 5.4 mL). We examined the 20-collected fractions obtained from the hydrochloric acid-methanol mixtures using ICP-MS. Once methanol was loaded into the column, there was no eluate of LREEs. Hence, it can be considered that methanol ruined the LN resin. Hydrocholoic acid dissolved in water is known to be effective for the separation of LREEs using LN resin.19 Figure 3 shows isocratic separations using hydrocholoic acid dissolved in water (concentrations ranging from 0.1 to 0.3 M) and 100-150μm sized resins. First, barium was not distributed on the column and eluted immediately. This result was consistent with the report by Hortwitz, wherein Kd of barium was zero when 0.01 M HNO3 was used with the LN resin. Then, La, Ce, and Nd sequencially were eluted depending on their relative orders of partitioning. Below 0.15 M HCl, the recoveries of three LREEs were very low. As the concentration of HCl was incresed (above 0.2 M HCl), the recoveries of three LREEs and peak efficiencies incresed, but the resolution decreased. Based on the above conditions, the optimum condition of eluent was 0.25 M HCl.

E1MPSV_2021_v12n4_186_f0003.png 이미지

Figure 3. Separation of LREEs and barium by GPEC depending on the concentrations of hydrochloric acid (0.1 M, 0.15 M, 0.2 M, 0.25 M, and 0.3 M, 25 cm column length, 100-150µm-sized LN resin) Other conditions as experimental section.

Separation of LREEs depending on the particle size of resin

Typically, resin particle size affects the resolution. Smaller particles provide higher resolution. Figure 4 shows the separation of three LREEs and barium with a 50-100μm- sized resin. In the case of larger particle sized resins using 0.25 M HCl (Figure 3), the resolution between La and Nd was 0.2. For the same eluent, the resolution increased to 0.8 with a 50-100μm-sized resin.

Further, to separate barium and lanthanum, gradient elution was developed using water as the elution solvent during initial 3 fraction volumes by GPEC (as shown in Figure 4). Based on the report that Kd of barium was ~500 with 0.008 M HNO3 and LN resin, barium was easily eluted out of the column with water. Compared to the isocractic elution using 0.25 M HCl (Figure 3), Ba and La were completely resolved via gradient elution (Figure 4). The recoveries and peak efficiencies also increased with smaller sized resins. Therefore, we suggest that the final optimal condition for GPEC method was as shown in Figure 4, with a 50-100μm-sized resin using 0.25 M HCl and water as the eluent.

Recovery and reproducibility of GPEC system

GPEC is a robust method, and it has great application potential for separation because of constant flow rate owing to the use of pressurized nitrogen gas. To evaluate the column reproducibility of this application, each column was tested for five consecutive runs, and the recoveries and RSDs of the recoveries of LREEs and barium were measured. Experimental conditions were the same as those used in Figure 4. Table 2 shows that >90% recoveries, except for Nd, were accomplished by GPEC for LREEs and barium, and the RSDs of recoveries were in the range 2.4%-4.9%. We performed the experiment with a new column and same procedures for investigating column-to-column reproducibility as those shown in Table 3. Thus, it was demonstrated that GPEC provides very high precision (3.1%-6.3%) for column-to-column reproducibility, and very high overall recoveries and reproducibility, as shown in Figure 5, showing that GPEC is suitable for separation of LREEs.

Table 2. Column reproducibility and recovery by GPEC.

E1MPSV_2021_v12n4_186_t0002.png 이미지

Table 3. Column-to-column reproducibility and recovery by GPEC.

E1MPSV_2021_v12n4_186_t0003.png 이미지

E1MPSV_2021_v12n4_186_f0005.png 이미지

Figure 5. Comparisons of recovery and reproducibility between column-to-column obtained by GPEC.

Conclusions

A new method for chemical separation of LREEs using GPEC is proposed. To overcome the isobaric interference in mass spectromtery, GPEC is a robust separation method as it is a microscaled chromatographic method. The optimal elution type, acid concentration, total volume of eluent, resin particle size, and amount of time needed for seapration of Ba, La, Ce, and Nd were verifed. Optimal conditions determined were 0.25 M HCl as elute with 50- 100μm sized LN resin as they provided high recoveries of the three LREEs considered in this study. For barium elution, a gradient method was developed with water as the solvent. Owing to the constant flow of nitrogen, the column reproducibility of recoveries by GPEC were in the range 2.4%–4.9%. The column-to-column reproducibility was in the range 3.1%–6.3%. These results show that GPEC gives high precision and good recovery for separation of LREEs and barium. Thus, this method may have considerable potential for analysis of LREEs from fission products using radioactive materials and less exposure of researchers.

Total analysis time required for a batch experiment was approximately 40 min using an elution volume of 270μL and flow rate of 67.5μL/min. Flow rate can be easily changed with a valve. Sample loading volume and elution volume can be changed by modifying the sample loop length. In future studies, analysis time can be further reduced by adjusting the flow rate and the elution volume for different elements.

Acknowledgments

This work was supported under the mid- and long-term nuclear research and development program though the National Research Foundation (NRF) of Korea (NRF- 2017M2A8A501476) funded by the Korean Ministry of Science and ICT. This research was also supported by a part of the Nuclear research and Development Program of the Ministry of Science and ICT. The authors thank Matthew M. Jones and Nick H. Erfurth of Idaho National Laboratory for help with the installation of a GPEC system.

Open Access

*Reprint requests to Jihye Kim

https://orcid.org/0000-0001-5794-975X

E-mail: jihyekim21@kaeri.re.kr

All the content in Mass Spectrometry Letters (MSL) is Open Access, meaning it is accessible online to everyone, without fee and authors’ permission. All MSL content is published and distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org / licenses/by/3.0/). Under this license, authors reserve the copyright for their content; however, they permit anyone to unrestrictedly use, distribute, and reproduce the content in any medium as far as the original authors and source are cited. For any reuse, redistribution, or reproduction of a work, users must clarify the license terms under which the work was produced.

References

  1. Gergoric, M.; Ekberg, C.; Steenari, B.-M.; Retegan, T. J. Sustain. Metall. 2017, 3, 601, DOI: 10.1007/s40831-017-0117-5.
  2. Kim, J. S.; Jeon, Y. S.; Park, S. D.; Han, S. H.; Kim, J. G. J. Nucl. Sci. Technol. 2007, 44, 1015, DOI: 10.1080/18811248.2007.9711341.
  3. Dry, D. E.; Bauer, E.; Petersen, L. A. J. Radioanal. Nucl. Chem. 2005, 263, 19, DOI: 10.1007/s10967-005-0005-5.
  4. Navarro, J.; Zhao, F. Front. Energy Res. 2014, 2, 45, DOI:10.3389/fenrg.2014.00045.
  5. McCulloch, M. T.; Wasserburg, G. J. Science 1978, 200, 1003, DOI: 10.1126/science.200.4345.1003.
  6. Charalampides, G.; Vatalis, K. I.; Apostoplos, B.; Ploutarch-Nikolas, B. Procedia Eco. Financ. 2015, 24, 126, DOI: 10.1016/S2212-5671(15)00630-9.
  7. Omodara, L.; Pitkaaho, S.; Turpeinen, E.-M.; Saavalainen, P.; Oravisjarvi, K.; Keiski, R.L. J. Clean. Prod. 2019, 236, 117573, DOI: 10.1016/j.jclepro.2019.07.048.
  8. Hirata, T. J. Mass Spectrom. Soc. Jpn. 2004, 52, 171, DOI: 10.5702/massspec.52.171.
  9. Bradley, V.; Manard, B.; Roach, B.; Metzger, S.; Rogers, K.; Ticknor, B.; Wysor, S.; Brockman, J.; Hexel, C. Minerals 2020, 10, 55, DOI: 10.3390/min10010055.
  10. Laycock, A.; Coles, B.; Kreissig, K.; Rehkamper, M. J. Anal. At. Spectrom. 2016, 31, 297, DOI: 10.1039/C5JA00098J.
  11. Chen, B.; He, M.; Zhang, H.; Jiang, Z.; Hu, B. Phys. Sci. Rev. 2017, 2, DOI: 10.1515/psr-2016-0057.
  12. Sekine, T.; Satio, N. Nature 1958, 181, 1464, DOI:10.1038/1811464a0.
  13. Dybczynski, R. J. Chromatogr. A 1970, 50, 487, DOI:10.1016/S0021-9673(00)97977-9.
  14. Roelandts, I.; Duyckaerts, G.; Brunfelt, A. O. Anal. Chim. Acta 1974, 73, 141, DOI: 10.1016/S0003-2670(01)82815-4.
  15. Strelow, F. W. E. Anal. Chem. 1980, 52, 2420, DOI:10.1021/ac50064a043.
  16. Horwitz, E. P.; Bloomquist, C. A. A. J. Inorg. Nucl. Chem. 1975, 37, 425, DOI: 10.1016/0022-1902(75)80350-2.
  17. Horwitz, E. P.; McAlister, D. R.; Bond, A. H.; Barrans, R. E.; Williamson, J. M. Appl. Radiat. Isot. 2005, 63, 23, DOI: 10.1016/j.apradiso.2005.02.005.
  18. Hirahara, Y.; Chang, Q.; Miyazaki, T.; Takahashi, T.; Kimura, J.-I. JAMSTEC Rep. Res. Dev. 2012, 15, 27, DOI: 10.5918/jamstecr.15.27.
  19. Pin, C.; Zalduegui, J. S. Anal. Chim. Acta 1997, 339, 79, DOI: 10.1016/S0003-2670(96)00499-0.
  20. Payne, R.; Schulte, S.; Douglas, M.; Friese, J.; Farmer, O.; Finn, E. J. Radioanal. Nucl. Chem. 2011, 287, 863, DOI: 10.1007/s10967-010-0838-4.
  21. Rahman, R. O. A.; Ibrahium, H. A.; Hung, Y.-T. Water 2011, 3, 551, DOI: 10.3390/w3020551.
  22. de Regge, P.; Boden, R. J. Radioanal. Nucl. Chem. 1977, 35, 173, DOI: 10.1007/BF02518224.
  23. Kim, J. S.; Jeon, Y. S.; Park, S. D.; Ha, Y.-K.; Song, K. Nucl. Eng. Technol. 2015, 47, 924, DOI: 10.1016/j.net.2015.08.002.
  24. Bera, S.; Sujatha, K.; Sivaraman, N.; Narasimhan, T. S. L. Radiochim. Acta 2019, 107, 685, DOI: 10.1515/ract-2018-3017.
  25. Steeb, J.; Mertz, C.; Sandi, G.; Bass, D.; Graczyk, D.; Goldberg, M. J. Radioanal. Nucl. Chem. 2012, 292, 757, DOI: 10.1007/s10967-011-1492-1.
  26. Sommers, J.; Cummings, D.; Giglio, J.; Carney, K. J. Radioanal. Nucl. Chem. 2009, 282, 591, DOI: 10.1007/s10967-009-0210-8.
  27. Mertz, C. J.; Kaminski, M. D.; Shkrob, I. A.; Kalensky, M.; Sullivan, V. S.; Tsai, Y. J. Radioanal. Nucl. Chem. 2015, 305, 199, DOI: 10.1007/s10967-015-4123-4.
  28. Marie, C.; Hiscox, B.; Nash, K. L. Dalton Trans. 2012, 41, 1054, DOI: 10.1039/C1DT11534K.
  29. Ostapenko, V.; Vasiliev, A.; Lapshina, E.; Ermolaev, S.; Aliev, R.; Totskiy, Y.; Zhuikov, B.; Kalmykov, S. J. Radioanal. Nucl. Chem. 2015, 306, 707, DOI: 10.1007/s10967-015-4331-y.