DOI QR코드

DOI QR Code

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul -

대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -

  • Kim, Jeong Ho (Department of Green Environment System, KonKuk Univ.) ;
  • Lee, Sang Hoon (Department of Green Technology Convergence, Graduate School, KonKuk Univ.) ;
  • Lee, Myung-Hun (Department of Green Technology Convergence, Graduate School, KonKuk Univ.) ;
  • Yoon, Yong Han (Department of Green Environment System, KonKuk Univ.)
  • 김정호 (건국대학교 친환경과학부 녹색환경시스템전공) ;
  • 이상훈 (건국대학교 대학원 녹색기술융합학과) ;
  • 이명훈 (건국대학교 대학원 녹색기술융합학과) ;
  • 윤용한 (건국대학교 친환경과학부 녹색환경시스템전공)
  • Received : 2020.03.24
  • Accepted : 2020.10.15
  • Published : 2020.10.31

Abstract

Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

불투수포장면적의 증가는 도심지 내 열환경 악화, 물순환체계 단절 등의 문제점과 더불어 인간의 여러 가지 신체적·정신적 질병에 원인이 되기도 한다. 이에 도시공원 내 거리에 따른 공기이온 실태와 거리별 기상요소 및 공기이온과의 상관성을 분석하여, 향후 도심지 내 대규모 도시공원 조성 혹은 리모델링에 있어서 기후적 측면의 건강성을 고려한 도시공원 조성의 기초자료로 제시하고자 하였다. 연구대상지는 서울시 송파구 올림픽공원을 대상으로 거리에 따라 4개 유형으로 구분한 뒤, 구간을 A, B로 분류하였다. 측정지점은 80지점을 선정한 후 토지피복 및 식생현황을 조사한 후 기상요소, 공기이온을 측정하였다. 첫째, 구간별 녹지율은 A구간 Center(90%) > Inner(70%) > Outer-inner(10%) = Outer(10%), B구간 Center(100%) > Inner(60%) > Outer-inner(30%) > Outer(0%) 순이었다. 둘째, 기상요소의 경우 기온의 경우 Outer(24.18℃) > Outer-inner(22.90℃) > Inner(22.43℃) > Center(21.719℃)으로 분석되었으며, 상대습도의 경우 Center(46.49%) > Inner(43.36%) > Outer-inner(42.41%) > Outer(38.53%)으로 분석되었다. 셋째, 공기이온 중 양이온의 경우 Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner(389.46ea/㎤) > Center(352.64ea/㎤)의 순이었으며, 음이온의 경우 Center(569.72ea/㎤) > Inner(499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer(292.02ea/㎤) 순으로 Center로 갈수록 증가하는 것으로 분석되었으며, 도로와 가까워질수록 감소하는 것으로 분석되었다. 이온지수의 경우 Center(1.67) > Inner(1.31) > Outer-inner(1.08) > Outer(0.71)으로 분석되었다. 넷째, 상관성 분석결과 정(+)의 상관인 것은 음이온, 이온지수로 도로로부터 공원 Center로 갈수록 증가하는 것으로 분석되었으며, 부(-)의 상관인 것은 기온, 일사량, 양이온으로 도로와 가까워질수록 증가하는 것으로 분석되었다.

Keywords

References

  1. Chee, C.K.(2009) Anionic effect(2nd ed.). Living Books, 183pp.
  2. Ham, K.J., K.Y. Park, M.S. Kim, J.M. Song, S.S. Lee and Y.S. Ok(2011) Research of Monoterpenes Content in the Atmosphere of Forest. KJSSF 44(6): 1126-1231. (in Korean with English abstract)
  3. Hwang, K.J., M.S. Rhee and D.Y. Ra(1998) Effect of Anion Generating Air Cleaner on the Components of ETS in a Closed Room. Journal of the Korean Society of Tobacco Science 20(1): 124-130. (in Korean with English abstract)
  4. Jo, Y.B.(2009) A Study on the Development of Suitable Locations Evaluation Model and Therapy Type to Therapeutic Forests. Ph.D. Dissertation, Univ. of Wonkwang, Korea. (in Korean with English abstract)
  5. Kim, H.S.(2012) The Difference in Temperature According to the Land Coverage and Vegetation Structure of Large-Scale Green Area in Seoul. Ph.M. Dissertation, Univ. of Seoul, Korea. (in Korean with English abstract)
  6. Kim, J.H., D.K. Oh and Y.H. Yoon(2015a) Comparative Analysis of Negative Air Ion Generation According to Vegetation Type of Green Space in Summer-Targeting to the Yangjae Citizen's Forest in Seochogu, Seoul. Urban Design 16(6): 19-33. (in Korean with English abstract)
  7. Kim, J.H., D.K. Oh and Y.H. Yoon(2015b) Effect of Green Space Type in Urban Park on Anions Distribution. Urban Design 16(1): 17-34. (in Korean with English abstract)
  8. Kim, J.H., D.K. Oh, W.J. Choi and Y.H. Yoon(2017) Air Ion Distribution of Traffic Volume in Urban Area-Wiryeseong main road, in Songpa-gu, Seoul-. JKSUE 17(2): 137-144. (in Korean with English abstract)
  9. Kim, J.H., S.H. Lee and Y.H. Yoon(2019) Evaluation of Air Ion According to the Type of Ridge in Urban Park-Focused on Tangeumdae Park in ChungJu-. Kor. J. Env. Eco. 33(5): 587-595. (in Korean with English abstract) https://doi.org/10.13047/KJEE.2019.33.5.587
  10. Kim, J.H., S.H. Lee., W.T. Kim and Y.H. Yoon(2018) Characteristics Regarding Ion Index by Geomorphic Structure-About Larix kaempferi of Wolaksan National Park. Kor. J. Env. Eco 32(5): 486-496. (in Korean with English abstract) https://doi.org/10.13047/KJEE.2018.32.5.486
  11. Kwon, Y.A.(2002) The influence of urban green areas on ambient air temperature in Seoul. Ph.D. Dissertation, Univ. of Konkuk, Korea. (in Korean with English abstract)
  12. Landsberg, H.E.(1981) The Urban climate. Elsevier.
  13. Lee, H.J., D.K. Lee and B.M. Kim(2018) Distribution of Negative Air Ion Concentration in Urban Neighborhood Park by Distance to Road-A Case of Yangjae Citizen's Forest, Seoul-27(2): 152-169. (in Korean with English abstract) https://doi.org/10.14249/EIA.2018.27.2.152
  14. Lee, S.H.(2019) Assessment of Air Ion based on Valley Microclimate: Focused on Mansu Valley in Woraksan National Park. Ph.M. Dissertation, Univ. of Konkuk, Korea. (in Korean with English abstract)
  15. Ling, X., R. Jayaratne and L. Morawska(2010) Air ion concentrations in various urban outdoor environments. Atmospheric Environment 44(18): 2186-2193. https://doi.org/10.1016/j.atmosenv.2010.03.026
  16. Oh, D.K.(2014) Effect of Negative Air Ions Distribution Impact by Form of Land Cover in Urban Park. Ph.M. Dissertation, Univ. of Konkuk, Korea. (in Korean with English abstract)
  17. Park, B.J., H. Hirano, T. Kagawa and Y. Miyazaki(2006) Physiological Effects of Sinrin-yoku(2). Jour Korean For. Soc. 2006: 554-556. (in Korean with English abstract)
  18. Um, T.W. and G.T. Kim(2010) Correlations Between Concentrations of Negative Ions and Forest Type, and Site Factors at National Forests in Yangyang-gun. Kor. J. Env. Eco. 24(5): 539-546. (in Korean with English abstract)
  19. Yamashita, M. and J.B. Fenn(1984) Negative ion production with the electrospray ion source. Physical Chemistry 88(20): 4671-4675. https://doi.org/10.1021/j150664a046
  20. Yoon, Y.H., B.H. Bae., W.T. Kim., B.J. Park., S.M. Cho and H.S. Cho(2007) Effects of Land Use Pattern on Urban Heat Island in Chungju City. (in Korean with English abstract)
  21. Yoon, Y.H., J.H. Yoon and J.H. Kim(2019) Evaluation of Pedestrian Space Ion Index by Land Use Type in Heat wave-Focused on Chungju-. Kor. J. Env. Eco. 33(3): 354-365. (in Korean with English abstract) https://doi.org/10.13047/KJEE.2019.33.3.354