DOI QR코드

DOI QR Code

Establishment of calculation methodology and thermal analysis for the development of a water calorimeter

  • Kang, M.Y. (Seoul National University) ;
  • Kim, Junhyuck (Seoul National University) ;
  • Choi, H.D. (Seoul National University)
  • 투고 : 2020.04.25
  • 심사 : 2020.04.28
  • 발행 : 2020.11.25

초록

As an early stage in the development of a water calorimeter, this study established a computer simulation methodology for analyzing the thermal behavior of a water calorimeter based on radiation transport and energy deposition. As a result, this study developed a method wherein the energy deposition distribution, which is obtained by applying Monte Carlo methods in water calorimeters, is directly used as a heat source for the thermal analysis model. Based on the proposed method, heat transfer in a water vessel and the effect of thermistor self-heating were analyzed. Through an analysis of the water velocities with and without a water vessel, it was found that a water vessel can serve as a convection barrier. Furthermore, it was confirmed that when considering thermistor self-heating, the water temperature change at the thermistor location is 0.219 mK higher compared to that when the thermistor was not considered. Therefore, thermistor self-heating must be considered to analyze the thermal behavior of a water calorimeter more accurately.

키워드

참고문헌

  1. H.O. Wyckoff, Radiation dosimetry: X-rays and gamma rays with maximum photon energies between 0.6 and 50 MeV, in: International Commission on Radiation Units and Measurements, 1969, pp. 1-16. ICRU Report no. 14.
  2. H.O. Wyckoff, Determination of absorbed dose in a patient irradiated by beams of X of gamma rays in radiotherapy procedures, in: International Commission on Radiation Units and Measurements, 1976, pp. pp1-10. ICRU Report 24.
  3. Norman V. Klassen, Carl K. Ross, Water calorimetry: the heat defect, J. Res. Natl. Inst. Stand. Technol. 102 (1997) 63-74. https://doi.org/10.6028/jres.102.006
  4. R.E. Tosh, H.H. Chen-Mayer, Frequency-domain characterization of heat conduction in sealed water calorimeters, Nucl. Instrum. Methods Phys. Res. A 580 (2007) 594-597. https://doi.org/10.1016/j.nima.2007.05.230
  5. J. Mulder, Water Calorimetry for Proton Therapy: Implementing a Primary Dose Measurement Standard, Groningen university, 2017 (Dissertation for PhD).
  6. https://www.engineeringtoolbox.com/water-steam-thermal-diffusivity-d_2058.html.
  7. R.J. Schulz, M.S. Weinhous, Phys. Med. 30 (1985) 1093-1099.
  8. S.R. Domen, A sealed water calorimeter for measuring absorbed dose, J. Res. Natl. Inst. Stand. Technol. 99 (1994) 121-141. https://doi.org/10.6028/jres.099.012
  9. Achim Krauss, The PTB water calorimeter for the absolute determination of absorbed dose to water in $^{60}Co$ radiation, Metrologia 43 (2006) 259-272. https://doi.org/10.1088/0026-1394/43/3/008
  10. C. Kessler, P.J. Allisy-Roberts, D.T. Burns, A.S. Guerra, R.F. Laitano, M. Pimpinella, Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for $^{60}Co$ ${\gamma}$ rays, Metrologia 47 (2010), 06002. https://doi.org/10.1088/0026-1394/47/1A/06002
  11. A.J. Williams, K.E. Rosser, A Status Report on the NPL Water Calorimeter, National Phusical Laboratory, 1998, pp. 1-43. CIRM 22.
  12. J.P. Seuntjens, C.K. Ross, N.V. Klassen, K.R. Shortt, A Status Report on the NRC Sealed Water Calorimeter, Natinal Reseach Council, 1999, pp. 1-49. PIRS-0584.
  13. B. Rapp, N. Perichon, M. Denoziere, J. Daures, A. Ostrowsky, J.-M. Bordy, The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays, Phys. Med. 58 (2013) 2769-2786.
  14. J. Medin, C.K. Ross, G. Stucki, N.V. Klassen, J.P. Seuntjens, Commissioning of an NRC-type sealed water calorimeter at METAS using $^{60}Co$ ${\gamma}$ rays, Phys. Med. 49 (2004) 4073-4086.
  15. K. Wang, S. Jin, X. Yang, J. Zhang, M. McEwen, C. Cojocaru, C. Ross, Development of a water calorimeter as the absorbed dose-to-water primary standard for China, Phys. Medica 30 (2014) e45-e74.
  16. E. Kawrakow, D.W. Mainegra-Hing, F.T. Roger, B.R. Walter, I. Kawrakow, D. Rogers, E. Mainegra, F. Tessier, B.R. Walters, The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport, Natinal Reseach Council, 2003, pp. 1-20. PIRS-0701.
  17. A. Krauss, M. Roos, Heat transport by material-dependent heating during absorption of radiation in the water absorbed dose calorimeter, Thermochim. Acta 337 (1999) 45-49. https://doi.org/10.1016/S0040-6031(99)00166-5
  18. S.R. Domen, An absorbed dose water calorimeter: theory, design, and performance, J. Res. Natl. Bur. Stand. 87 (1982) 211-235. https://doi.org/10.6028/jres.087.016
  19. http://www.nist.gov/pml/data/star/index.cfm.
  20. C.Y. Yi, K.J. Chun, J.P. Jeong, Absolute Measurement of Air Kerma of KRISS 60Co Gamma Irradiation System, 40th The Korean Physical Society (KPS) Spring Meeting, Daejeon, Korea, April 9, 2010.
  21. C.Y. Yi, K.J. Chun, S.H. Hah, H.M. Kim, Energy spectrum of KRISS 60Co irradiation system, Korean J. Med. Phys. 19 (2008) 139-141.
  22. ANSYS ICEM CFD 11.0 Tutorial Manual, ANSYS,INC., Pennsylvania, 2007.
  23. https://www.nist.gov/srd/refprop.
  24. https://www.ptb.de/cms/en/ptb/fachabteilungen/abt6/fb-62/623-unit-of-absorbed-dose-to-water/calorimetric-determination-of-the-absorbed-dose-to-water.html.