DOI QR코드

DOI QR Code

Study on bond behavior of steel reinforced high strength concrete after high temperatures

  • Chen, Zongping (College of Civil Engineering and Architecture, Guangxi University) ;
  • Zhou, Ji (College of Civil Engineering and Architecture, Guangxi University) ;
  • Wang, Xinyue (College of Civil Engineering and Architecture, Guangxi University)
  • Received : 2019.09.10
  • Accepted : 2020.07.23
  • Published : 2020.08.25

Abstract

This paper presents experimental results on bond-slip behavior of steel reinforced high-strength concrete (SRHC) after exposure to elevated temperatures. Three parameters were considered in this test: (a) high temperatures (i.e., 20℃, 200℃, 400℃, 600℃, 800℃); (b) concrete strength (i.e., C60, C70, C80); (c) anchorage length (i.e., 250 mm, 400 mm). A total of 17 SRHC specimens subjected to high temperatures were designed for push out test. The load-slip curves at the loading end and free end were obtained, the influence of various variation parameters on the ultimate bond strength and residual bond strength was analyzed, in addition, the influence of elevated temperatures on the invalidation mechanism was researched in details. Test results show that the shapes of load-slip curves at loading ends and free ends are similar. The ultimate bond strength and residual bond strength of SRHC decrease first and then recover partly with the temperature increasing. The bond strength is proportional to the concrete strength, and the bond strength is proportional to the anchoring length when the temperature is low, while the opposite situation occurs when the temperature is high. What's more, the bond damage of specimens with lower temperature develops earlier and faster than the specimens with higher temperature. From these experimental findings, the bond-slip constitutive formula of SRHC subjected to elevated temperatures is proposed, which fills well with test data.

Keywords

References

  1. ACI Committee 408 (2003), Bond and Development of Straight Reinforcing Bars Intension, ACI 408R-03, American Concrete Institute, Michigan, America.
  2. AIJ (1997), Recommendations for Design and Construction of Concrete Filled Steel Tubular Structure, Architectural Institute of Japan, Tokyo, Japan.
  3. Alavi-Fard, M. and Marzouk, H. (2004), "Bond of high-strength concrete under monotonic pull-out loading", Mag. Concrete Res., 56(9), 545. https://doi.org/10.1680/macr.2004.56.9.545.
  4. Ansari, F. and Li, Q. (1998), "High-strength concrete subjected to triaxial compression", Mater. J., 95(6), 747-755.
  5. Azizinamini, A., Stark, M., Roller, J.J. and Ghosh, S.K. (1993), "Bond performance of reinforcing bars embedded in high-strength concrete", Struct. J., 90(5), 554-561. http://worldcat.org/oclc/13846957.
  6. Brooks, J.J., Johari, M.M. and Mazloom, M. (2000), "Effect of admixtures on the setting times of high-strength concrete", Cement Concrete Compos., 22(4), 293-301. https://doi.org/10.1016/S0958-9465(00)00025-1.
  7. Bryson, J.O. and Mathey, R.G. (1962), "Surface condition effect on bond strength of steel beams in concrete", J. ACI, 59(3), 397-406.
  8. BS EN 1994-1-1 (2004), Eurocode 4: Design of Composite Steel and Concrete Structures: Part 1.1, General Rules and Rules for Building, British Standards Institution, London, Britain.
  9. Candappa, D.C., Sanjayan, J.G. and Setunge, S. (2001), "Complete triaxial stress-strain curves of high-strength concrete", J. Mater. Civil Eng., 13(3), 209-215. https://doi.org/10.1061/(ASCE)0899-1561(2001)13:3(209).
  10. CEB-FIP (1990), Model Code 90, First Draft, Committee Euro-International du Beton, Europe.
  11. Chen, Z.P., Liu, X. and Zhou, W.X. (2018), "Residual bond behavior of high strength concrete-filled square steel tube after elevated temperatures", Steel Compos. Struct., 27(4), 509-523. http://dx.doi.org/10.12989/scs.2018.27.4.509.
  12. Chen, Z.P., Xu, J.J., Liang, Y. and Su, Y.S. (2014), "Bond behaviors of shape steel embedded in recycled aggregate concrete and recycled aggregate concrete filled in steel tubes", Steel Compos. Struct., 17(6), 929-949. http://dx.doi.org/10.12989/scs.2014.17.6.929.
  13. Donza, H., Cabrera, O. and Irassar, E.F. (2002), "High-strength concrete with different fine aggregate", Cement Concrete Res., 32(11), 1755-1761. https://doi.org/10.1016/S0008-8846(02)00860-8.
  14. Hussein, A. and Marzouk, H. (2000), "Behavior of high-strength concrete under biaxial stresses", ACI Mater. J., 97(1), 27-36.
  15. Ji, X., Sun, Y., Qian, J. and Lu, X. (2015), "Seismic behavior and modeling of steel reinforced concrete (SRC) walls", Earthq. Eng. Struct. Dyn., 44(6), 955-972. https://doi.org/10.1002/eqe.2494.
  16. Kim, H.K. and Lee, H.K. (2011), "Use of power plant bottom ash as fine and coarse aggregates in high-strength concrete", Constr. Build. Mater., 25(2), 1115-1122. https://doi.org/10.1016/j.conbuildmat.2010.06.065.
  17. Limbachiya, M.C., Leelawat, T. and Dhir, R.K. (2000), "Use of recycled concrete aggregate in high-strength concrete", Mater. Struct., 33(9), 574. https://doi.org/10.1007/BF02480538.
  18. Liu, C., Lv, Z., Bai, G. and Yin, Y. (2018), "Experiment study on bond slip behavior between section steel and RAC in SRRC structures", Constr. Build. Mater., 175, 104-114. https://doi.org/10.1016/j.conbuildmat.2018.04.120.
  19. Lu, X. and Yang, J. (2015), "Seismic behavior of T-shaped steel reinforced concrete shear walls in tall buildings under cyclic loading", Struct. Des. Tall Spec. Build., 24(2), 141-157. https://doi.org/10.1002/tal.1158.
  20. Nath, P. and Sarker, P. (2011), "Effect of fly ash on the durability properties of high strength concrete", Procedia Eng., 14, 1149-1156. https://doi.org/10.1016/j.proeng.2011.07.144.
  21. Pothisiri, T. and Panedpojama,n P. (2013), "Modeling of mechanical bond-slip for steel-reinforced concrete under thermal loads", Eng. Struct., 48, 497-507. https://doi.org/10.1016/j.engstruct.2012.10.015.
  22. Roeder, C.W. (1985), "Bond stress of embedded steel shapes in concrete[C]", Compos. Mix. Constr., ASCE, 227-240.
  23. Roeder, C.W., Chmielowski, R. and Brown, C.B. (1999), "Shear connector requirements for embedded steel sections", J. Struct. Eng., 125(2), 142-151. https://doi.org/10.1061/(ASCE)07339445(1999)125:2(142).
  24. Shansuo, Z., Yong, Y. and Jianyang, X. (2002), "Study on bond-slip performance between steel and concrete in SRC structures", China Civil Eng. J., 35(4), 47-51. (in Chinese) https://doi.org/10.15951/j.tmgcxb.2002.04.009.
  25. Skalny, J. and Roberts, L.R. (1987), "High-strength concrete", Ann. Rev. Mater. Sci., 17(1), 35-56. https://doi.org/10.1146/annurev.ms.17.080187.000343.
  26. Wang, C., Shen, Y., Yang, R. and Wen, Z. (2017), "Ductility and ultimate capacity of prestressed steel reinforced concrete beams", Math. Prob. Eng., 2017, Article ID 1467940, 6. https://doi.org/10.1155/2017/1467940.
  27. Wee, T.H., Chin, M.S. and Mansur, M.A. (1996), "Stress-strain relationship of high-strength concrete in compression", J. Mater. Civil Eng., 8(2), 70-76. https://doi.org/10.1061/(ASCE)0899-1561(1996)8:2(70).
  28. Yogendran, V., Langan, B.W., Haque, M.N. and Ward, M.A. (1987), "Silica fume in high-strength concrete", Mater. J., 84(2), 124-129.
  29. Zeng, L., Zhou, Q., Xu, C., Wu, Y. and Tu, X. (2015), "Cyclic performance of concrete-encased composite columns with T-shaped steel sections", Int. J. Civil Eng., 13(4), 455-467. https://doi.org/10.22068/IJCE.13.4.455.
  30. Zhao, X., Wen, F., Chen, Y., Hu, J., Yang, X., Dai, L. and Cao, S. (2018), "Experimental study on the static performance of steel reinforced concrete columns with high encased steel ratios", Struct. Des. Tall Spec. Build., 27(15), e1536. https://doi.org/10.1002/tal.1536.
  31. Zhong, T. and Qing, Y. (2012), "Residual bond strength in steel reinforced concrete columns after fire exposure", Fire Saf. J., 53, 19-27. https://doi.org/10.1016/j.firesaf.2012.06.010.
  32. Zhu, H. (2016), "Crack formation of steel reinforced concrete structure under stress in construction period", Frattura ed Integrita Strutturale, 10(36), 191-200. https://doi.org/10.3221/IGF-ESIS.36.19.