DOI QR코드

DOI QR Code

A Study on the circuit design and measurement method for the measurement of active points on skin

피부 활성점 측정을 위한 회로설계 및 측정방법연구

  • Kim, Min Soo (Dept. of Avia. Info. Com. Eng., Kyungwoon University) ;
  • Cho, Young Chang (Dept. of Avia. Info. Com. Eng., Kyungwoon University)
  • Received : 2020.08.07
  • Accepted : 2020.09.14
  • Published : 2020.09.30

Abstract

The method of measuring skin active points is a technique for obtaining a lot of biometric information because it is measured with convenience, low cost and non-invasive methods. In this paper, we used in a three electrode measure method that has the advantage of measuring the impedance of the APs under the skin. The impedance measuring method is well illustrated by a simple model of an equivalent electrical circuit that correlates well with experimental results. The characteristic frequencies of APs are about 15-30HZ higher than that of surrounding skin and the values of measured reactance are about 35-77KΩ smaller. This technology analyzed accurately and objectively the reactance and characteristic frequency of APs and the surrounding skin using a non-invasive measuring system.

피부 활성점(경혈) 측정 방법은 편리성, 저비용 및 비 침습으로 측정하기 때문에 많은 생체정보를 얻기 위한 기술이다. 본 연구에서는 피부 아래에 활성점을 측정할 수 있는 장점이 있는 3전극 측정방법을 사용되었다. 임피던스측정방법은 측정실험 결과와 관련성이 있는 등가전기회로를 통해서 증명되었다. 활성점의 특성주파수는 주변 피부보다 15-30Hz 높고, 리액턴스는 35-77kΩ 더 작게 측정되었다. 이 기술은 비침습 측정 시스템을 이용해서 활성점과 주변피부의 리액턴스와 특성주파수를 정확하고 객관적으로 분석되었다.

Keywords

References

  1. H. Jain, D. Isaacson, P. M. Edic, and J. C. Newell, "Electrical impedance tomography of complex conductivity distributions with noncircular boundary," IEEE Trans. Biomedical Engineering, vol.44, pp.1051-1-60, 1997. DOI: 10.1109/10.641332
  2. S. Grimnes, "Impedance measurement of individual skin surface electrodes," Med. Biol. Eng. Comput., vol.21, pp.750-755, 1983. DOI: 10.1007/BF02464038.
  3. O. G. Martinsen, S. Grimnes, and J. Karlwen, "Electrical methods for skin moisture assessment," skin Pharmacol., vol.8, pp.237-245, 1995. DOI: 10.1159/000211353.
  4. J. Hyvarinen, M. Karlsson. "Low-resistance skin points that may coincide with acupuncture loci," Med. Biol. vol.55, pp.88-94. 1977.
  5. T. Croley. "Electrical acupuncture point conductance in the living compared to that in the dead," Am. J. Acupunct., vol.14, pp.57-60, 1986. DOI: 10.1089/acm.2007.7193
  6. S. Rezaei, A. Khorsand, J. Jamali, "Characterisation of human skin impedance at acupuncture point PC4 Ximen and pericardium meridian using the four-electrode method," Acupunct. Med. vol.30, pp.127-31, 2012. DOI: 10.1136/acupmed-2011-010071
  7. R. Becker, A. Marino, "Electromagnetism and life," State University of New York Press; 1982.
  8. W. Zhang, R. Xu and Z. Zhu, "The Influence of acupuncture on the impedance measured by four electrodes on meridians," Acupuncture Electro-Therap Res Int J vol.24, pp.181-1888, 1999. DOI: 10.3727/036012999816356273
  9. N. Barlea, H. Sibianu and R. Ciupa, "Electrical detection of acupuncture points," Acta Electrotech Napocensis, vol.41, pp.59-61, 2000.
  10. H. Johng, J. Cho, H. Shin, K. Soh , T. Koo, S. Choi, et al, "Frequency dependence of impedance at the acupuncture point Quze(PC3)," IEEE Eng. Med. Biol. vol.21, pp.33-36, 2002. DOI: 10.1109/MEMB.2002.1000183
  11. A. Comunetti A, S. Laage, N. Schiessl and A. Kistler, "Characteristics of human skin conductance at acupuncture point," Experientia, vol.51, pp. 328-331, 1995. DOI: 10.1007/BF01928888
  12. M S Kim and Geunbae Lim, "Electrical Characteristics Analysis of Biological Active Points using Real Time Measurement," The 2nd International Meeting on Microsensors and Microsystems, 166. 2006.
  13. Y. Nakatani, "Essai sur l,acupuncture Chinoise," Clinic of Chinese Medicine, vol.3, No.7, pp.54, 1956.
  14. R. Voll, "Messbara acupuncture-diagnostic und Therapie fur den praktier," Erfahrungsheilkunde, vol.4, 1955.
  15. T. Yamamoto, Y. Yamamoto, and A. Yoshida et al, "Measurement of low-resistance points on the skin by dry roller electrodes," IEEE Trans. Biomedical Eng., vol.35, No.3, pp.203-209, 1988. DOI: 10.1109/10.1363
  16. E. F. Prokhorov and J. Gonzalez-Hernandez et al, "In vivo electrical characteristics of human skin, including at biological active points," Med. Biol. Eng. Comput., vol.38, pp.507-511, 2000. DOI: 10.1007/BF02345745
  17. Li. Dachao et al," A Method for Measuring the Volume of Transdermally Extracted Interstitial Fluid by a Three-Electrode Skin Resistance Sensor," Sensors, vol.14, pp.7084-7095, 2014. DOI: 10.3390/s140407084
  18. H. Fricke, "The Maxwell-Wagner dispersion in a suspension of colloidal particle in electrolyte solution," J. Phys. Chem., vol.57, pp.934-937, 1953. https://doi.org/10.1021/j150510a018