References
- Guidry, P. E., Anderson, R. P., Clement, G. and Westveer, S., "Hot Surface Ignition Temperatures: Their Impact on Electrical Area Classification Plans," IEEE IND APPL MAG, 24, 31-38(2018). https://doi.org/10.1109/MIAS.2017.2740462
- Shrivastava, V., Mohan, G., Feinstein, N. and Bhatia, N., "An Innovative Approach to Hazardous Area Classification - Three Dimensional (3D) Modeling of Hazardous Areas," Proc. of Pet. Chem. Ind. Tech. Conf. PCIC, 1-9(2016).
- Bozek, A., "Application of IEC 60079-10-1 Edition 2.0 for Hazardous Area Classification," IEEE Trans Ind Appl, 54, 1881-1889(2018). https://doi.org/10.1109/TIA.2017.2785258
- Jespen, T., Zone Classification-Natural Gas, ATEX-Explosive Atmospheres. Springer Series in Reliability Engineering, Springer, cham, pp. 93-105 (2016).
- Tommasini, R., Pons, E. and Palamara, F., "Area Classification for Explosive Atmospheres: Comparison Between European and North American Approaches," IEEE Trans Ind Appl, 50, 3128-3134(2014). https://doi.org/10.1109/TIA.2014.2306980
- Miranda, J. T., Camacho, E. M., Formoso, J. A. F. and Garcia, J. D. R., "Comparative Study of Methodologies Based on Standard UNE 60079/10/1 and Computational Fluid Dynamics (CFD) to Determine Zonal Reach of Gas-generated Atex Explosive Atmospheres," J. Loss Prev Process Ind., 26, 839-850(2013). https://doi.org/10.1016/j.jlp.2013.02.015
- Jung, Y. J. and Lee, C. J., "A Study on Gas Explosion Hazardous Ranges for International Electrotechnical Commission Technical Standards," J. Korean Soc. Saf. Journal, 33, 39-45(2018).
- Bishop, D. N., Jagger, D. M. and Propst, J. E., "New Area Classification Guidelines, in: Record of Conference Papers," IEEE Industry Applications Society 45th Annual Petroleum and Chemical Industry Conference (Cat. No. 98CH36234), 9-19(2013).
- IEC, IEC 60079-10-1 : Classification of areas - Explosive gas atmospheres., International Electrotechnical Commission (2015) https://webstore.iec.ch
- Zohdirad, H., Ebadi, T., Givehchi, S. and Meysami, H., "Grid-based Individual Risk Calculation in the Classification of Hazardous Area with a Risk-based Approach," J Loss Prev Process Ind, 43, 98-105(2016). https://doi.org/10.1016/j.jlp.2016.05.007
- Kim, J. H., Lee, M. K., Kil, S. H., Kim, Y. G. and Ko, Y. K., "Area Classification of Hazardous Gas Facility According to KGS GC101 Code," J. Korean Inst. Gas., 23, 46-64(2019).
- Hahn, B. H. and Valentine, D. T., Essential MATLAB for Engineers and Scientists, Academic Press, New York(2017).
- Givehchi, S., Zohdirad, H. and Ebadi, T., "Utilization of Regression Technique to Develop a Predictive Model for Hazard Radius From Release of Typical Methane-rich Natural Gas," J. Loss Prev. Process Ind., 44, 24-30(2016). https://doi.org/10.1016/j.jlp.2016.08.015
Cited by
- Overview of the Legal Design Basis for Passive Fire Protection in Korea and the Direction of Further Development vol.13, pp.4, 2020, https://doi.org/10.3390/su13041674