DOI QR코드

DOI QR Code

A Study on the Monitoring Technique for Musculoskeletal Safety Management and Implementation of the System

근골격계 안전관리를 위한 모니터링 기법에 관한 연구 및 시스템 구현

  • Received : 2020.06.16
  • Accepted : 2020.06.28
  • Published : 2020.06.30

Abstract

Manufacturing workers are easily exposed to the risk of musculoskeletal disorders caused by repetitive tasks in their working environment. This is due to problems with occupational characteristics that repeatedly use the body. However, the current lack of monitoring systems for monitoring and prevention has led to an increase in workers' exposure to risks each year. This paper presents how to solve these problems in real working environment by producing wearable devices using IMU sensors. After wearing a wearable type device, the user's movement is judged through data analysis by receiving the rotation value according to musculoskeletal movement. At this time, the risk is determined by measuring the number of rotations of the user by eliminating bias and eliminating cumulative error, acquiring sophisticated data, and analyzing it in the form of dynamic threshold values. Using the wearable device proposed in this paper, the effect of this method could be checked through a web page measuring the number of rotations for elbow musculoskeletal disorders.

제조업 근로자는 근무 환경에서 반복 작업에 의한 근골격계 질환의 위험에 쉽게 노출되어 있다. 이는 신체를 반복적으로 이용하는 직업 특성상의 문제에 기인한다. 하지만 현재 감시 및 예방을 위한 모니터링 시스템이 제공되지 않아 매년 위험에 대한 근로자의 노출도가 증가하고 있다. 본 논문에서는 IMU 센서를 사용한 웨어러블 장치 제작을 통해 실제 작업 환경에서의 이러한 문제를 해결하는 방법에 대해 제시한다. 웨어러블 형태의 장치를 착용 후, 근골격계 움직임에 따른 회전 값을 받아와 데이터 분석을 통해 사용자의 움직임을 판단해낸다. 이때, 바이어스 제거와 누적 오차를 제거해 정교한 데이터 취득하여 이를 동적 임곗값 형식으로 분석하여 사용자의 회전 운동 횟수를 측정해내어 위험도를 판단한다. 본 논문에서 제안한 웨어러블 장치를 이용 팔꿈치 근골격계 질환에 대한 회전 횟수를 측정하는 웹 페이지를 통해 본 방법의 효과를 확인할 수 있었다.

Keywords

References

  1. KOSHA, "Status of industrial accidents in 2019", pp. 22, April. 2020.
  2. Korean Association of Occupational Environmental Medicine, "A Study on the Actual Condition of Occupational Medical Use from Accident Occurrence of Musculoskeletal Diseases", pp. 2, Ministry of Employment and Labor, Feb, 2017.
  3. KOSHA, "Guidelines for investigating hazards of musculoskeletal burden work", pp. 28-31, Dec, 2018
  4. "Introduction of musculoskeletal disease prevention business", KOSHA, accessed Jun 10, 2020, http://www.kosha.or.kr/kosha/business/musculoskeletal_a_c.do
  5. K. T. Kim, "Development of an Apparatus to Measure Musculoskeletal Load for Construction Workers Using Accelerometers", JOURNAL OF THE ARCHITECTURAL INSTITUTE OF KOREA Structure & Construction 28(1), pp. 167-174, Jan, 2012. https://doi.org/10.5659/JAIK_SC.2012.28.1.167
  6. H. H. Kim, "Development of motion analysis device using inertial measurement device and trend of neck joint research", The Institute of Electronics and Information Engineers, The Magazine of the IEEE 43(12), pp. 57-64, Dec, 2016.
  7. J. H. Lim, J. H. Shim, H. Y. Jung, "IMU/UWB Sensor Fusion Using Moving Average Filter for Indoor Positioning of Mobile Robot", Journal of Institute of Control, Robotics and Systems 26(4), pp. 242-248, April, 2020. https://doi.org/10.5302/J.ICROS.2020.20.0019
  8. W. C. Jung, J. K. Lee, "IMU-based Position Estimation of Lower Limbs via a Combination of Kinematic Modeling with Minimal Utilization of Magnetometers", Journal of Institute of Control, Robotics and Systems 26(4), pp. 222-233, April, 2020. https://doi.org/10.5302/J.ICROS.2020.20.0006
  9. J. B. Ko, J. S. Yoon, C. K. Lee, T. M. Byeon, J. S. Hong, "A Study on the Determining the Optimal Location of IMU Sensors in Dynamic Balance Measurement by Comparing Absolute Percentage Error between the 3D Motion Capture System and IMU Sensor", Journal of the Ergonomics Society of Korea 38(6), pp. 419-434, Dec, 2019. https://doi.org/10.5143/JESK.2019.38.6.419
  10. J. K. Lee and E. J. Park, "Minimum-order Kalman filter with vector selector for accurate estimation of human body orientation," IEEE Transactions on Robotics, vol. 25, no. 5, pp. 1196-1201, Oct, 2009. https://doi.org/10.1109/TRO.2009.2017146
  11. G. Ligorio and A. M. Sabatini, "A novel Kalman filter for human motion tracking with an inertial-based dynamic inclinometer," IEEE Transactions on Biomedical Engineering, vol. 62, no. 8, pp. 2033-2043, 2015. https://doi.org/10.1109/TBME.2015.2411431
  12. M. S. Kim, S. K. Park, "Golf Swing Phase Estimation Using Single IMU Located on Different Body Parts", The Korean Society of Mechanical Engineers, pp. 1701-1702, Nov, 2019.
  13. S. J. Park, J. K. Park, J. H Choe," Development of a 2D Posture Measurement System to Evaluate Musculoskeletal Workload", Journal of the Ergonomics Society of Korea 24(3), pp. 43-52, Aug , 2005.
  14. J. H. Jo, J. N. Kim, J. J. Kim, W. S. Chong, "Development of real-time posture analysis monitoring system by measurement of knee joint angle in ADL", The HCI Society of Korea, pp. 643-646, Jan, 2018.
  15. Department of Labor, "Hazardous factors investigation method of musculoskeletal burden work", KOSHA, pp. 11-17, 2010.
  16. K. Y. Pyo, D. M. Lee, H. H. Cho, K. I. Kang, "Development of Measurement Method of Musculoskeletal Load for Construction Workers using Wearable Motion Recognition Sensor", Korea Institute of Building Construction, pp. 123-124, May, 2019.
  17. McAtamney, L., Corlett, E. N., RULA: a survey method for the investigation of work- related upper limb disorders, Applied Ergonomics, 24(2), 91-99, 1993. https://doi.org/10.1016/0003-6870(93)90080-S
  18. Kilbom, A., Assessment of physical exposure in relation to work-related musculos- keletal disorders - What information can be obtained from systematic observation?, Scandinavian Journal of Work, Environment & Health, 20, 30-45, 1994.
  19. H. S. Park, Y. K. Lee, S. H. Yim, "Prevention of the Musculoskeletal Disorders at Upper or Lower Extremities", Journal of the Ergonomics Society of Korea 29(4), pp. 455-463, Aug. 2010. https://doi.org/10.5143/JESK.2010.29.4.455