Acknowledgement
본 연구는 한국전력공사의 2016년 선정 주력연구개발과제연구비에 의해 지원되었음(과제번호: R16SA06).
References
- The Ministry of Land, Infrastructure & Transportation, "Design Criteria for Common Utility Tunnels," 2016.
- The Ministry of Land, Transport & Maritime Affairs, "Design Criteria for Concrete Structures," 2012.
- Korea Electric Power Corporation, "Seismic Design Guidelines for Transmission & Distribution Facilities," May 2014.
- The Ministry of Interior & Safety, "Common Application of Seismic Design Criteria," Apr. 2017.
- KEPCO Research Institute, "Study on Seismic Reinforcement Plans for Existing Transmission and Distribution Cable Tunnels and Electric Facilities around Yangsan Fault (TR 9346 S2019 0195)," pp. 3-150, Aug. 2019.
- Duhee Park, Jongho Shin, Seung Yun, "Seismic Analysis of Tunnels in Transverse Direction Part I: Estimation of Seismic Tunnel Response via Method of Seismic Displacement," Journal of the Korean Geotechnical Society, Vol. 26, No. 6, pp. 57-70, Jun. 2010.
- Yongmin Kim, Sangseom Jeong, Yonghee Lee, Jungbum Jang, "Seismic Design of Vertical Shaft using Response Displacement Method," Journal of the Korean Society of Civil Engineers, Vol. 30, No. 6C, pp. 241-253, Nov. 2010.
- Hojune Ann, Sanggeun Song, Daehong Min, Sangmi An, Jungsik Kong, "Experimental and Analytical Evaluation of the Seismic Performance of a Concrete Box Structure Strengthened with Pre-flexed Members," Journal of Computational Structural Engineering Institute of Korea, Vol. 29, No. 5, pp. 397-403, Oct. 2016. https://doi.org/10.7734/COSEIK.2016.29.5.397
- Choonghyun Kang, Jungwon Huh, Innjoon Park, Kyeongmin Hwang, Jungbum Jang, "A Simple Seismic Vulnerability Sorting Method for Electric Power Utility Tunnels," Journal of the Korea Institute for Structural Maintenance and Inspection, Vol. 22, No. 5, pp. 110-118, Sep. 2018. https://doi.org/10.11112/JKSMI.2018.22.5.110