References
- M. Belluscio, R. de Leo, A. Pantaleo, A. Vox, Effects of finite dimensions in source-detector solid-angle evaluation, Nucl. Instrum. Methods 114 (1974) 145-147. https://doi.org/10.1016/0029-554X(74)90349-8
- R. Carchon, E. Van Camp, G. Knuyt, R. Van De Vyver, J. Devos, H. Ferdinande, A general solid angle calculation by a Monte Carlo method, Nucl. Instrum. Methods 128 (1975) 195-199. https://doi.org/10.1016/0029-554X(75)90796-X
- L. Wielopolski, The Monte Carlo calculation of the average solid angle subtended by a right circular cylinder from distributed sources, Nucl. Instrum. Methods 143 (1977) 577-581. https://doi.org/10.1016/0029-554X(77)90249-X
- L. Wielopolski, Monte Carlo calculation of the average solid angle subtended by a parallelepiped detector from a distributed source, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 226 (1984) 436-448. https://doi.org/10.1016/0168-9002(84)90062-7
- B.T. Stavroulaki, S.N. Kaplanis, Monte-Carlo solutions of the solid angle integrals for radiation detectors, Comput. Phys. Commun. 18 (1979) 7-12. https://doi.org/10.1016/0010-4655(79)90020-1
-
S.N. Kaplanis, Geometric, effective solid angles and intrinsic efficiencies of a
$3{\times}3$ in. NaI(Tl) for isotropic and non-isotropic photon emission, Int. J. Appl. Radiat. Isot. 33 (1982) 127-135. https://doi.org/10.1016/0020-708X(82)90219-8 - J. Cook, Solid angle subtended by two rectangles, Nucl. Instrum. Methods 178 (1980) 561-564. https://doi.org/10.1016/0029-554X(80)90838-1
- H.R. Vega Carrillo, Geometrical efficiency for a parallel disk source and detector, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 371 (1996) 535-537. https://doi.org/10.1016/0168-9002(95)00998-1
- J. Zhang, X. Chen, C. Zhang, G. Li, J. Xu, G. Sun, Development of a software package for solid-angle calculations using the Monte Carlo method, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 736 (2014) 40-45. https://doi.org/10.1016/j.nima.2013.10.048
- M.Y. Kang, G.M. Sun, J. Kim, H.D. Choi, Determination of HPGe peak efficiency for voluminous gamma-ray sources by using an effective solid angle method, Appl. Radiat. Isot. 116 (2016) 69-76. https://doi.org/10.1016/j.apradiso.2016.07.015
- L. Ruby, J.B. Rechen, A simpler approach to the geometrical efficiency of a parallel-disk source and detector system, Nucl. Instrum. Methods 58 (1968) 345-346. https://doi.org/10.1016/0029-554X(68)90491-6
- L. Ruby, Further comments on the geometrical efficiency of a parallel-disk source and detector system, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 337 (1994) 531-533. https://doi.org/10.1016/0168-9002(94)91124-X
- H. Gotoh, H. Yagi, Solid angle subtended by a rectangular slit, Nucl. Instrum. Methods 96 (1971) 485-486. https://doi.org/10.1016/0029-554X(71)90624-0
- R.P. Gardner, K. Verghese, On the solid angle subtended by a circular disc, Nucl. Instrum. Methods 93 (1971) 163-167. https://doi.org/10.1016/0029-554X(71)90155-8
- K. Verghese, R.P. Gardner, R.M. Felder, Solid angle subtended by a circular cylinder, Nucl. Instrum. Methods 101 (1972) 391-393. https://doi.org/10.1016/0029-554X(72)90214-5
- Y.S. Selim, M.I. Abbas, Source-detector geometrical efficiency, Radiat. Phys. Chem. 44 (1994) 1-4. https://doi.org/10.1016/0969-806X(94)90093-0
- Y.S. Selim, M.I. Abbas, Direct calculation of the total efficiency of cylindrical scintillation detectors for extended circular sources, Radiat. Phys. Chem. 48 (1996) 23-27. https://doi.org/10.1016/0969-806X(95)00047-2
- Y.S. Selim, M.I. Abbas, M.A. Fawzy, Analytical calculation of the efficiencies of gamma scintillators. Part I: total efficiency for coaxial disk sources, Radiat. Phys. Chem. 53 (1998) 589-592. https://doi.org/10.1016/S0969-806X(97)00277-6
- Y.S. Selim, M.I. Abbas, Analytical calculations of gamma scintillators efficiencies - II. Total efficiency for wide coaxial circular disk sources, Radiat. Phys. Chem. 58 (2000) 15-19. https://doi.org/10.1016/S0969-806X(99)00357-6
- J.T. Conway, Generalizations of Ruby's formula for the geometric efficiency of a parallel-disk source and detector system, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 562 (2006) 146-153. https://doi.org/10.1016/j.nima.2006.02.197
- J.T. Conway, Geometric efficiency for a circular detector and a ring source of arbitrary orientation and position, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 640 (2011) 99-109. https://doi.org/10.1016/j.nima.2011.03.014
- S. Pomme, L. Johansson, G. Sibbens, B. Denecke, An algorithm for the solid angle calculation applied in alpha-particle counting, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 505 (2003) 286-289. https://doi.org/10.1016/S0168-9002(03)01070-2
- S. Pomme, A complete series expansion of Ruby's solid-angle formula, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 531 (2004) 616-620. https://doi.org/10.1016/j.nima.2004.05.088
- S. Pomme, J. Paepen, A series expansion of Conway's generalised solid-angle formulas, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 579 (2007) 272-274. https://doi.org/10.1016/j.nima.2007.04.054
- M.J. Prata, Analytical calculation of the solid angle defined by a cylindrical detector and a point cosine source with orthogonal axes, Radiat. Phys. Chem. 66 (2003) 387-395. https://doi.org/10.1016/S0969-806X(03)00006-9
- M.J. Prata, Solid angle subtended by a cylindrical detector at a point source in terms of elliptic integrals, Radiat. Phys. Chem. 67 (2003) 599-603. https://doi.org/10.1016/S0969-806X(03)00144-0
- M.J. Prata, Analytical calculation of the solid angle defined by a cylindrical detector and a point cosine source with parallel axes, Radiat. Phys. Chem. 69 (2004) 273-279. https://doi.org/10.1016/S0969-806X(03)00474-2
- M. Prata, Analytical calculation of the solid angle subtended by a circular disc detector at a point cosine source, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 521 (2004) 576-585. https://doi.org/10.1016/j.nima.2003.10.098
- S. Tryka, Calculation of the solid angle subtended by a cylinder at a point, Appl. Radiat. Isot. 70 (2012) 2466-2470. https://doi.org/10.1016/j.apradiso.2012.07.002
- D.M. Timus, M.J. Prata, S.L. Kalla, M.I. Abbas, F. Oner, E. Galiano, Some further analytical results on the solid angle subtended at a point by a circular disk using elliptic integrals, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 580 (2007) 149-152. https://doi.org/10.1016/j.nima.2007.05.055
- M.I. Abbas, S. Hammoud, T. Ibrahim, M. Sakr, Analytical formulae to calculate the solid angle subtended at an arbitrarily positioned point source by an elliptical radiation detector, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 771 (2015) 121-125. https://doi.org/10.1016/j.nima.2014.10.061
- A. Hamzawy, Validation of analytical formula for the efficiency calibration of gamma detectors using coaxial and off-axis extended sources, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 618 (2010) 216-222. https://doi.org/10.1016/j.nima.2010.02.275
-
A. Hamzawy, Simple analytical formula to calculate
$\gamma$ -ray cylindrical detectors efficiencies, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 624 (2010) 125-129. https://doi.org/10.1016/j.nima.2010.09.013 - M.S. Badawi, Accurate calculation of well-type detector geometrical efficiency using sources with different shapes and geometries, J. Instrum. 10 (2015) P10017. https://doi.org/10.1088/1748-0221/10/10/P10017
- J.T. Conway, Analytical solution for the solid angle subtended at any point by an ellipse via a point source radiation vector potential, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 614 (2010) 17-27. https://doi.org/10.1016/j.nima.2009.11.075
- R.L. Burden, J.D. Faires, Numerical Analysis, ninth ed., Brooks Cole, 2011.
Cited by
- Non-destructive radiological characterization applied to fusion waste management vol.173, 2020, https://doi.org/10.1016/j.fusengdes.2021.112805